EEWORLDEEWORLDEEWORLD

Part Number

Search

5421.9151101

Description
IEC Appliance Inlet C14 Modular Assembling Options
File Size633KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet View All

5421.9151101 Overview

IEC Appliance Inlet C14 Modular Assembling Options

Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
IEC Appliance Inlet C14 Modular Assembling Options
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuse-
holder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and
medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
- Alternative: version without line filter Felcom 64
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
References
Weblinks
General Product Information
Approvals
- Line switch with other rocker marking
- VDE License Number: 101307
- UL License Number: E72928
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
EMC Products

About IAR Embeded Serial Download
The chip I use is ADuC7026, and the development tool is IAR Embeded. When I use RS-232 to download the program, it is successful. It can also be debugged online and run correctly, but after unplugging...
mikerain Embedded System
【Qingke Open1081】Provide some information to everyone
[i=s]This post was last edited by wo4fisher on 2014-11-6 17:38[/i] This is the mico document, this is the official address of MICO: [url=http://www.mxchip.com/mico/]http://www.mxchip.com/mico/[/url]Th...
wo4fisher RF/Wirelessly
CAD2006 Tutorial
Hey guys, where can I download the CAD2006 tutorial?...
QE_ZPT Industrial Control Electronics
Hey guys, how can I check the execution steps of a program in IAR?
How can I check the number of execution steps of a program in IAR? I want to calculate the execution time of the subroutine based on the number of execution steps. Please give me more advice and be mo...
451432837 Microcontroller MCU
Five types of knowledge that embedded engineers need
I would like to ask an expert, what are the five most important knowledge that an embedded (software/hardware) engineer needs? Can you simply list the corresponding five books? Thank you....
loserfeng Embedded System
About 51 MCU and FPGA communication
How to write a communication program between 51 MCU and FPGA? Define a 16-bit register. When the upper four bits are 0000, it controls another register when it is 0001. And so on. How to write a progr...
c51arm7 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2706  1778  2596  1595  2480  55  36  53  33  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号