EEWORLDEEWORLDEEWORLD

Part Number

Search

5423.6153101

Description
IEC Appliance Inlet C14 Modular Assembling Options
File Size633KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet View All

5423.6153101 Overview

IEC Appliance Inlet C14 Modular Assembling Options

Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
IEC Appliance Inlet C14 Modular Assembling Options
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuse-
holder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and
medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
- Alternative: version without line filter Felcom 64
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
References
Weblinks
General Product Information
Approvals
- Line switch with other rocker marking
- VDE License Number: 101307
- UL License Number: E72928
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
EMC Products

The huge error of the internal temperature sensor of MSP430
[i=s] This post was last edited by helloxieyu on 2015-8-21 10:03 [/i] [b]The huge error of the MSP430 internal temperature sensor: [/b] According to the manual, the ADC voltage is equivalent to 3.55mV...
helloxieyu Microcontroller MCU
The small board that I welded myself at school
...
7leaves DIY/Open Source Hardware
Image display problem in Wince remote debugging
I use VS 2005 to develop Wince using WTL library. When I do remote debugging, the picture display fails. When I do single-step debugging, I find that CBitmap bmp; bmp.LoadBitmap(IBD_BACKGROUND); does ...
qiaogang Embedded System
F28069 XRS pin level
This is my first time using F28069. I made a circuit board and encountered a problem. My F28069, the XRS pin is always low level after power on? I directly connected a pull-up resistor, but it is stil...
wellsking Microcontroller MCU
EEWORLD University Hall - Wildfire uCOS-III Kernel Implementation and Application Development Practical Guide
WildFire uCOS-III Kernel Implementation and Application Development Practical Guide : https://training.eeworld.com.cn/course/5357The book "uCOS-III Kernel Implementation and Application Development Pr...
JFET MCU
Weird network card problem
Two ARM boards are transmitting a large amount of data. After a period of transmission, the network card cannot be pinged. Could it be that the application program is killing the network card? After r...
adadad111 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1777  1116  912  114  1482  36  23  19  3  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号