EEWORLDEEWORLDEEWORLD

Part Number

Search

5432.2051121

Description
IEC Appliance Inlet C14 Modular Assembling Options
File Size633KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet View All

5432.2051121 Overview

IEC Appliance Inlet C14 Modular Assembling Options

Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
IEC Appliance Inlet C14 Modular Assembling Options
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuse-
holder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and
medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
- Alternative: version without line filter Felcom 64
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
References
Weblinks
General Product Information
Approvals
- Line switch with other rocker marking
- VDE License Number: 101307
- UL License Number: E72928
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
EMC Products

Can I choose NTFS as the partition format of the SSD???
As title...
tornadofeng Embedded System
Using RAM to construct a smoothing window filtering method
Sliding window filtering is a good filtering method. This method does not affect the validity of the data. Each data is associated with the previous data, so that the instantaneous peak or burr has li...
eeleader FPGA/CPLD
How to improve the accuracy of this clock program?
I looked through the previous program and found that this program does not use the real-time clock chip to complete the clock function. I checked the time with the stopwatch and found that it was 4 se...
qrswll MCU
28335 drives a 1602
傻逼了,用28335驱动一个1602,竟然没搞定。 #include "DSP2833x_Device.h"// DSP2833x Headerfile Include File #include "DSP2833x_Examples.h"// DSP2833x Examples Include Filevoid LCD_Init(void) {LCD_delay(1000);LCD_delay(...
elvike DSP and ARM Processors
Recruiting weekend part-time CAN bus lecturer
[i=s]This post was last edited by Xiao Qingning on 2018-7-4 17:48[/i] The corporate training company is training employees for units and is recruiting part-time teachers for CAN bus on a long-term bas...
小青柠 Talking about work
Hey guys, this is the ADC code of MSP430F5529, how do I fill it in?
void ADC_init(){//AD access port multiplexing//Port output mode selection is input//Configure ADC12CTLx to enable reference voltage//Configure ADC12CTLx to turn on AD and set sampling clock//Configure...
jkjkl MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2165  476  594  1453  2682  44  10  12  30  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号