Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1
File Size263KB,3 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Compare View All

3101.0060.15 Overview

Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1

Fuseholders
https://www.schurter.com /PG02
FPG6
Shock-Safe Fuseholder, 5 x 20 mm, Slotted Cap, Press, IEC 60335-1
250 VAC · 2.5 W / 10 A (VDE) · 500 V · 16 A (UL/CSA)
Description
See below:
Approvals and Compliances
Applications
Weblinks
- Household appliances
- Medical equipment
pdf datasheet, html-datasheet, General Product Information, Packaging
details, Distributor-Stock-Check, Detailed request for product, Microsite
- Meets the new requirements of IEC 60335-1 for appliances in unatten-
ded use (clause 30.2.3). This includes the enhanced requirements of
glow wire tests acc. to IEC 60695-2-12 and -13.
- Press-fit mount, secured with potting compound on the rear side
- White color available on request
Technical Data
PC2
5 x 20 mm
Panel Mount, Front Side
Press-Fit
Solder or Quick-Connect 4.8 x 0.5 mm
250 VAC , 500 V (UL/CSA)
10 A (VDE), 16 A (UL/CSA)
2.5 W / 10 A @ Ta 23 °C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Degree of Protection
IP 40 / IP 67
Protection Class
Suitable for appliances with protection
class I acc. to IEC 61140
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category
40/085/21 acc. to IEC 60068-1
Material: Socket
Thermoplastic, black, UL 94V-0
Material: Terminals
Tin-Plated Copper Alloy
Unit Weight
5.3 g
Storage Conditions
0 °C to 60 °C, max. 70% r.h.
Product Marking
, Type, Rated Voltage, Power Acc./
Current Rating, Approvals
Shock-Safe Category
Fuse-Link
Mounting
Attachment
Terminal
Rated Voltage
Rated current
Rated Power Acceptance IEC
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Iron
Soldering Profile
350 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 2
350 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 2
10 mΩ at 20 mV acc. to IEC 60127-6
> 3 kV
> 4 kV between L/N-PE
(50 Hz; 1 min)
> 2.5 kV between L-N
> 6 kV between L/N-PE
> 10 MΩ between L-N
> 100 MΩ between L/N-PE
(500 VDC; 1 min)
III acc. to IEC 60664-1
3 acc. to IEC 60664-1
acc. to IEC 60068-2-6, test Fc
max 2.5 mm
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Resistance to Vibration
Panel Thickness
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: FPG6
Approval Logo
Certificates
VDE Approvals
UL Approvals
KTL Approvals
Certification Body
VDE
UL
KTL
Description
VDE Certificate Number: 127216
UL File Number: E39328
Korea Testing Laboratory
Fuses
1

3101.0060.15 Related Products

3101.0060.15 3101.0060 3101.0160.15 3101.0160 3101.0260 3101.0260.15 FPG6
Description Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1 Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1 Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1 Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1 Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1 Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1 Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1
Is ARM really better than 51?
ARM was praised for its superior performance when it first appeared. Is ARM really better than 51? But apart from the fact that its price is much higher than 51, its superior performance is not hinder...
wanggq 51mcu
FPGA Definitive Guide
The Definitive Guide to FPGAs...
青城山下 FPGA/CPLD
Research and development of GPRS module based on Windows CENET.pdf
Research and development of GPRS module based on Windows CENET.pdf...
yuandayuan6999 MCU
IAP updater issue with LPC4357
Has anyone done an IAP program upgrade for LPC MCU? In LPC43xx, there are BANK-A and BANK-B dual banks. How do I upgrade the program? In the BIN file to be upgraded, there are two separate addresses f...
jplzl10000 NXP MCU
LM3S811 FIFO Receive
I set the receive FIFO to 4-byte trigger, and the PC sent 6 bytes at once. I would like to ask when the remaining two bytes will be received. Also, when I process the received 4 bytes in the interrupt...
intermec Microcontroller MCU
Comprehensive operational amplifier documentation
Comprehensive operational amplifier documentation...
jsznbzas Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 389  2610  538  2737  1028  8  53  11  56  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号