EEWORLDEEWORLDEEWORLD

Part Number

Search

3101.0225.15

Description
SCHURTER - 3101.0025 - FUSE HOLDER
CategoryTopical application    Wireless rf/communication   
File Size300KB,3 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet View All

3101.0225.15 Overview

SCHURTER - 3101.0025 - FUSE HOLDER

Fuseholders
https://www.schurter.com /PG02
FPG2
Shock-Safe Fuseholder, 5 x 20 mm, Slotted Cap/Fingergrip, Rear-Side, IP 40 / IP 67, IEC 60335-1
Fingergrip
250 VAC · 2.5 W / 10 A (VDE) · 500 V · 16 A (UL/CSA)
Description
See below:
Approvals and Compliances
Applications
Weblinks
- Household appliances
- Medical equipment
pdf datasheet, html-datasheet, General Product Information, Packaging
details, Distributor-Stock-Check, Detailed request for product, Microsite
- Meets the new requirements of IEC 60335-1 for appliances in unatten-
ded use (clause 30.2.3). This includes the enhanced requirements of
glow wire tests acc. to IEC 60695-2-12 and -13.
- Mounting from rear-side
Technical Data
Shock-Safe Category
Fuse-Link
Mounting
Attachment
Terminal
Rated Voltage
Rated current
Rated Power Acceptance IEC
PC2
5 x 20 mm
Panel Mount, Rear Side
Fixing Nut
Solder or Quick-Connect 4.8 x 0.5 mm
250 VAC (VDE), 500 V (UL/CSA)
10 A (VDE), 16 A (UL/CSA)
2.5 W / 10 A @ Ta 23 °C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Degree of Protection
IP 40 / IP 67
Protection Class
Suitable for appliances with protection
class I acc. to IEC 61140
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category
40/085/21 acc. to IEC 60068-1
Material: Socket
Thermoplastic, black, UL 94V-0
Material: Terminals
Tin-Plated Copper Alloy
Unit Weight
6.01 g
Storage Conditions
0 °C to 60 °C, max. 70% r.h.
Product Marking
, Type, Rated Voltage, Rated current,
Power Rating, Approvals
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Resistance to Vibration
Admissible Torque on Fixing
Nut
Panel Thickness
Iron
Soldering Profile
350 °C / 3 sec acc. to IEC 60068-2-20,
Test Ta, method 2
350 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 2
10 mΩ at 20 mV acc. to IEC 60127-6
> 3 kV between life parts
(50 Hz; 1 min)
> 4 kV between life parts
10 MΩ between life parts
(500 VDC; 1 min)
III acc. to IEC 60664-1
3 acc. to IEC 60664-1
acc. to IEC 60068-2-6, test Fc
max 1.2 Nm
max 8 mm
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: FPG2
Approval Logo
Certificates
VDE Approvals
UL Approvals
KTL Approvals
Certification Body
VDE
UL
KTL
Description
VDE Certificate Number: 127216
UL File Number: E39328
Korea Testing Laboratory
Fuses
1
Why can't I enter my interrupt? Please help me.
#include \"LF2047REGS.H\"void led_test(void);main(){asm(\" setc SXM \" ;asm(\" clrc OVM \" ;asm(\" clrc CNF \" ;asm(\" setc INTM \");SCSR1=0x83fe; // CLKOUT is the CPU clock, 4 times the frequency, tu...
daxingxian Analogue and Mixed Signal
[Book now for a prize live broadcast] Interpret ON Semiconductor's power solutions and gain insight into the latest power technology trends
What are the trends in the solar inverter power supply field? The falling cost of solar panels has led to an increase in solar power generation facilities around the world. The inverter is an integral...
nmg Power technology
Learning experience of Yidian Power Supply - Summary of using Yidian Power Supply
It has been three months since I participated in the forum event in August and got the chance to get the EasyPower module. In the actual project, I also used 14203 and 12002 chips, which really made i...
fengzhang2002 Analogue and Mixed Signal
Things to note when using MSP430
1. #i nclude<> means to be in the editor setting directory, #i nclude "" means to be in the current project directory. 2. To call a function in another file, put the function file in the current proje...
qinkaiabc Microcontroller MCU
Device packaging
...
PowerAnts PCB Design
C programming frequently asked questions
This is a book that specifically answers common questions about C programming. The book covers a wide range of topics and is accompanied by a large number of vivid examples. C is an excellent language...
zhangkai0215 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1182  1718  1552  2049  51  24  35  32  42  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号