EEWORLDEEWORLDEEWORLD

Part Number

Search

FD300G1C

Description
Power/Signal Relay, SPDT, Momentary, 0.3A (Coil), 6VDC (Coil), 1800mW (Coil), 10A (Contact), 56VDC (Contact), DC Input, DC Output, Socket Mount,
CategoryMechanical and electronic products    relay   
File Size865KB,12 Pages
ManufacturerEsterline Technologies Corporation
Download Datasheet Parametric View All

FD300G1C Overview

Power/Signal Relay, SPDT, Momentary, 0.3A (Coil), 6VDC (Coil), 1800mW (Coil), 10A (Contact), 56VDC (Contact), DC Input, DC Output, Socket Mount,

FD300G1C Parametric

Parameter NameAttribute value
MakerEsterline Technologies Corporation
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPANEL MOUNTABLE
body width13.3 mm
body height25.7 mm
Body length or diameter26 mm
Maximum coil current (DC)0.3 A
Coil operating voltage (DC)5 V
Coil power1800 mW
Coil release voltage (DC)0.2 V
Coil resistance20 Ω
Maximum coil voltage (DC)6 V
Coil/Input Power TypeDC
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@56VDC
Maximum contact voltage (DC)56 V
Contact/Output Power TypeDC
Electrical life100000 Cycle(s)
JESD-609 codee3
Installation featuresSOCKET MOUNT
operating hours16 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
physical size26mm x 13.3mm x 25.7mm
Relay actionMOMENTARY
Relay functionSPDT
Relay typePOWER/SIGNAL RELAY
release time16 ms
sealCORROSION PROOF; HERMETICALLY SEALED
surface mountNO
Terminal surfaceTIN
Termination typeSNAP-ON
FD300
ENGINEERING DATA SHEET
HERMETICALLY SEALED RELAY
1 PDT/10 AMP/56VDC
Polarized, non latching hermetically sealed relay
1 PDT NC - NO (DB - DM)
Contact arrangement
Coil supply
Direct current
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions max.
of case in mm
Balanced-force design.
Hermetically sealed, corrosion protected metal can.
Intrinsically safe relay.
10 Amps / 56 Vdc
40 grams max.
26 x 25.7 x 13.3
APPLICATION NOTES:
001
002
APPLICABLE SOCKETS:
S300
SF300CE40E
CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
100,000 cycles
20,000 cycles
50 cycles
400,000 cycles
Contact rating per
pole and load type
resistive load
inductive load (L/R=5ms)
resistive overload
at 25% rated resistive load
Load Current in Amps
@56Vdc
10
6
40
Featuring
LEACH
©
power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 3/06
- 93 -
Page 1 of 4
Selection of winning works of the 5th National Undergraduate Electronic Design Competition
This is the information I collected about the electronic design competition. I hope it will be of reference value to everyone....
wyhui73 MCU
TI has started mailing out the prizes from last time
The bag and massager have been received...
Sur TI Technology Forum
About the problem of 2440+CE5.0 freezing when starting
Hey guys, I have a 2440+CE5.0 board that I made for a few days, but it occasionally fails to start when I start it. However, it works fine after I restart it several times. Does anyone have the same p...
nwf1987 Embedded System
I'm a complete novice. Why can't I read data from the serial port?
import machinechuankou=machine.UART(2,9600)while Ture:x=chuankou.read()if x=='a':print('cg')else:print('sb')...
shsznbdr MicroPython Open Source section
Can't burn the program, the chip is dead
Hardware platform: Wanli development board STM32F103VbT6 Z IAR4.42 and keil3.22 have been tried. RAM, flash startup prompts NO DEVICE CONNECT, ISP doesn't work either, haha, low power consumption test...
KESKY stm32/stm8
The problem that the dialog box below EVC cannot be initialized~~
I set up a dialog box under the EVC simulator to establish a TCP connection, but the control initialization code added in OnInitDialog() was not displayed in the dialog box. I don't know why. Could an...
263775063 Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2286  1380  2190  1457  2711  47  28  45  30  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号