Power entry modules without line filter
https://www.schurter.com /PG05
KD-Bowdencable
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Bowden-Line Switch 2-pole and Voltage Selector
Order required accessories separately
C14
70° C
Description
- Panel Mount :
Screw-on version from front or rear side, snap-in version from front
side
- 4 Functions :
Appliance Inlet Protection class I , Line switch for bowdencable actu-
ation 2-pole , Fuseholder with interchangeable fuse drawer for Fuse-
links 5x20 mm or 6.3x32 mm , with or without voltage selector (step)
- Quick connect terminals 4.8 x 0.8 mm
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
SE
6 A / 250 VAC; 50 Hz
8 A / 125 VAC; 60 Hz
> 3 kVAC between L-N
> 4 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
Fuseholder
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
, tin-plated
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1.5/2/2.5 mm
Thermoplastic, black, UL 94V-0
Line Switch
PH
A
Terminal
Panel Thickness S
Material: Housing
Allowable Operation Tempe-
rature
IP-Protection
Insulation cover
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
-O
UT
Approvals and Compliances
Characteristics
- All single elements are already wired
- The fuse drawer "Fingergrip" can be removed by hand
- Suitable for use in equipment according to IEC/UL 60950
Other versions on request
- For protection class II
- Without voltage selector
References
Alternative: version with line filter
CD-Bowdencable
Last order date: 30.06.2017
Last delivery date: 30.09.2017
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product
appliance inlet/-outlet
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Voltage Selector
C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32 mm
5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per
pole
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole)
per pole
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Switch for bowdencable 2-pole, non-
illuminated, acc. to IEC 61058-1
Technical Details
optional, step, 2-4 digits
Connectors
1
KD-Bowdencable
Approvals
Power entry modules without line filter
https://www.schurter.com /PG05
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: KD
Approval Logo
Certificates
VDE Approvals
UL Approvals
CSA Approvals
CQC Approvals
Certification Body
VDE
UL
CSA
CQC
Description
Certificate Number: 40029908
Product standards
Product standards that are referenced
Organization
Design
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Standard
IEC 60320-1
IEC 60127-6
IEC 61058-1
UL 498
CSA C22.2 no. 42
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Designed for applications acc.
Standard
Compliances
Identification
Details
The product complies with following Guide Lines
CE declaration of conformity
China RoHS
REACH
PH
A
Medical Equipment
2
SE
IEC 60601-1
Initiator
SCHURTER AG
SCHURTER AG
SCHURTER AG
SCHURTER AG
SCHURTER AG
IEC/UL 60950
Connectors
-O
UT
UL File Number: E93617
CSA Certification Record: 38456
CCC File Number:
Description
Appliance couplers for household and similar general purposes
Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Switches for appliances. Part 1. General requirements
Standard for Attachment Plugs and Receptacles
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Description
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Suitable for use in medical equipment according to IEC/UL 60601-1
Power entry modules without line filter
https://www.schurter.com /PG05
KD-Bowdencable
Dimensions [mm]
Screw-on mounting
30
R6
R 4.5
4.8x0.8
55
ø 3.2
0.6
M3/ø 3.6
R 3.1
27.2
Snap-in mounting
30
R 4.5
SE
32.6
R 3.1
18
27.2
27.5
78
+0.2
66.5
0
66.2
69
Diagrams
without voltage selector
4
without voltage selector
4
7
PH
A
1
2
1
2
1a
L
2a
N
1a
L
2a
N
E
E
1-pole
2-pole
-O
UT
ø 6.3x90°
66.5
0
R 3
-0.2
0
230
34.3
18
27.5
2
2.2
27.5
+0.2
0
78
55
0.6
4.8x0.8
S
±0.1
230
R 3
-0.2
0
2
2.2
27.5
+0.2
0
with voltage selector
6 54 3
with voltage selector
6 54 3
7
1
2
75.5
±0.15
83.5
75.5
66.2
+0.2
1
2
1a
L
E
2a
N
1a
L
E
2a
N
1-pole
2-pole
Connectors
3
KD-Bowdencable
Derating Curves
Fuses
5 x 20 mm (1-pole)
Admissible power acceptance in Watt
2.5
2.0
1.5
1.0
0.5
0.0
0
20
40
60
80
100
I = 1.0 I
n
I = 0.7 I
n
I = << I
n
Power entry modules without line filter
https://www.schurter.com /PG05
Fuses
5 x 20 mm (2-pole, per pole)
Admissible power acceptance in Watt
per pole
2.0
Ambient air temperature T
a
°C
Fuses
6.3 x 32 mm (1-pole)
Admissible power acceptance in Watt
3.15
2.5
2.0
1.5
1.0
0.5
0.0
0
20
40
60
80
100
I = 1.0 I
n
I = 0.7 I
n
I = << I
n
All Variants
Type
KD-Bowdenzug
KD-Bowdenzug
KD-Bowdenzug
KD-Bowdenzug
KD-Bowdenzug
Panel mounting
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
Screw
Screw
SE
Panel Thickness
s [mm]
1.5
2
Fuseholder
1-pole
Line Switch
Switch for bowdencable
1-pole
Switch for bowdencable
2.5
1-pole
Switch for bowdencable
1.5
2-pole
Switch for bowdencable
2.5
-
-
2-pole
Switch for bowdencable
1-pole
2-pole
Switch for bowdencable
Switch for bowdencable
Ambient air temperature T
a
°C
PH
A
KD-Bowdenzug
KD-Bowdenzug
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit
10 Pcs
Required Accessory
Description
Fusedrawer 3
Fusedrawer for Fuse Links 5x20 mm resp. 6.3x32 mm
Fingergrip, 5 x 20, 2-pole
Fingergrip, 5 x 20, 1-pole
4303.2401
4303.2403
4303.2406
4303.2408
...
Extra-Safe, 5 x 20, 2-pole
Extra-Safe, 5 x 20, 1-pole
4
Connectors
-O
UT
1.5
I = 1.0 I
n
1.0
I = 0.7 I
n
I = < < I
n
0.5
0.0
0
20
40
60
80
100
Ambient air temperature T
a
°C
Fuses
6.3 x 32 mm (2-pole, per pole)
2.5
2.0
1.5
1.0
0.5
0.0
Admissible power acceptance in Watt
per pole
I = 1.0 I
n
I = 0.7 I
n
I = < < I
n
0
20
40
60
80
100
Ambient air temperature T
a
°C
Voltage selector max.
4 pos*
-
-
-
-
-
-
-
Order Number
KD11.4199.105
KD11.4199.107
KD11.4199.109
KD14.4199.105
KD14.4199.109
KD11.4199.151
KD14.4199.151
Power entry modules without line filter
https://www.schurter.com /PG05
KD-Bowdencable
Accessories
Cord retaining kits
Cord retaining strain relief
Flat head, A
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
Appliance Outlet further types to KD-Bowdencable
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
SE
Connector further types to KD-Bowdencable
Power Cord Overview complete
VAC13KS, Overview, diverse Connector IEC C13, cord end:
Power Cord further types to KD-Bowdencable
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
Mating Outlets/Connectors shuttered
PH
A
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
-O
UT
4700.0001
4787
4788
5091
4782
4022
4785
4012
...
4300-06
VAC13KS
Connectors
5
01.12.2017