EEWORLDEEWORLDEEWORLD

Part Number

Search

4302.5337

Description
6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER
CategoryThe connector    The connector   
File Size536KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

4302.5337 Overview

6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER

4302.5337 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time7 weeks
Other featuresSTANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings6A, 125VAC
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialTHRMOPLASTIC
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
KFB2
IEC Appliance Inlet C14 with Filter, Line Switch 2-pole
C14
See below:
70° C
Approvals and Compliances
Description
Characteristics
-
-
-
-
- Panel mount :
Screw-on mounting from front side
- 3 Functions :
Appliance Inlet Protection class I , Line Switch 2-pole , Line filter in
standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
All single elements are already wired
Line switch non-illuminated
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
References
Alternative: version without line filter
KEB2
We recommend for new applications
DC12
Alternative: Standard version
DC12
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Landing Page
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 1'900'000 h acc. to MIL-HB-217 F
Line Switch
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material: Housing
Line Filter
MTBF
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: KFB2
Approval Logo
Certificates
VDE Approvals
UL Approvals
CQC Approvals
Certification Body
VDE
UL
CQC
Description
Certificate Number: 40004665 (FKT)
UL File Number: E72928 (FKT)
CCC Certificate Number: CQC18001200932
EMC Products
1

4302.5337 Related Products

4302.5337 4302.5312 4302.5314 4302.5311 4302.5313 4302.5335 4302.5339 4302.5333 KFB2
Description 6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER 6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER 6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER 6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER 6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER 4A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER 6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER 6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER 6A, 125VAC, MALE, MAINS POWER CONNECTOR, SOLDER
Connector type MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR MAINS POWER CONNECTOR
Coupling type SNAP SNAP SNAP SNAP SNAP SNAP SNAP SNAP SNAP
Installation type PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL
Options GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE
Shell material THRMOPLASTIC THRMOPLASTIC THRMOPLASTIC THRMOPLASTIC THRMOPLASTIC THRMOPLASTIC THRMOPLASTIC THRMOPLASTIC THRMOPLASTIC
Total number of contacts 3 3 3 3 3 3 3 3 3
Is it lead-free? Lead free Lead free Lead free Lead free Lead free Lead free Lead free Lead free -
Is it Rohs certified? conform to conform to conform to conform to conform to conform to conform to conform to -
Maker SCHURTER - SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER SCHURTER -
package instruction ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT -
Reach Compliance Code compliant compli compliant compliant compliant compliant compliant compliant -
ECCN code EAR99 - EAR99 EAR99 EAR99 EAR99 - EAR99 -
Factory Lead Time 7 weeks 7 weeks 7 weeks 7 weeks 7 weeks 7 weeks 7 weeks 7 weeks -
Other features STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT -
Contact to complete cooperation NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED -
Contact point gender MALE MALE MALE MALE MALE MALE MALE MALE -
Contact material NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED -
DIN compliance NO NO NO NO NO NO NO NO -
IEC compliance YES YES YES YES YES YES YES YES -
MIL compliance NO NO NO NO NO NO NO NO -
Power Connector Ratings 6A, 125VAC 2A, 125VAC 6A, 125VAC 1A, 125VAC 4A, 125VAC 4A, 125VAC 10A, 125VAC 2A, 125VAC -
Plug information MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE MULTIPLE MATING PARTS AVAILABLE -
Termination type SOLDER SOLDER SOLDER SOLDER SOLDER SOLDER SOLDER SOLDER -
Base Number Matches 1 1 1 1 1 1 1 1 -
Lamp voltage loss calculation software
A small software to calculate voltage loss...
LED123 Power technology
New energy vehicle electromagnetic compatibility testing
[b][size=14px]Mainly based on the following standards:[/size][/b] [size=14px] 1.GBT18487.1-2015 "General requirements for conductive charging systems for electric vehicles"[/size] [size=14px] 2.GBT184...
bjhyyq Automotive Electronics
【Want Talent】Beijing-3 embedded positions
1 Embedded ARM 1.1 Job ResponsibilitiesResponsible for embedded product software requirements analysis, architecture design, and solution output; Responsible for the design, debugging, upgrade and opt...
Coen0518 Recruitment
Help. MSP-EXP430FR5739 cannot achieve online debugging
I saw someone else post that online debugging can be achieved. Mine has never been able to do it. I can download it but I can't debug it online. Please help me. There is the following error in the com...
daijun Microcontroller MCU
AD7705 sometimes cannot be initialized normally
I recently used AD7705 to measure PT100, and it was basically normal. Recently, I suddenly found a problem. I hope that friends with experience can help me analyze it. The CS terminal of AD7705 is oft...
xmhyb Embedded System
The Industrial Knowledge Challenge is now open. Compete for the top 20 and win the glory that belongs to you!
[font=微软雅黑][size=3][color=#ff0000][b]Event details: [/b][/color][/size][/font][url=https://bbs.eeworld.com.cn/huodong/TI_gytzs_20180601/][font=微软雅黑][size=3]TI Industrial Month inspiration has no limit...
EEWORLD社区 TI Technology Forum

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1604  2766  291  1454  806  33  56  6  30  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号