Power Entry Modules with Line Filter
https://www.schurter.com /PG06
KPF
Filter for Backpack Mounting to KP01
KP01 Base Module
(not enclosed)
Approvals and Compliances
Description
- Component :
Snap-in version from rear-side
- 1 Function :
Line filter in standard and medical version
- For PCB mounting
- Only in combination with base-module type KP01
Characteristics
- Line filter for ?backpack? mounting for modules type KP01 (snaps
onto rear of KP01)
- Electrical connection done on the PCB
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 70 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
For PCB mounting
Thermoplastic, black, UL 94V-0
Line Filter
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 2'600'000 h acc. to MIL-HB-217 F
MTBF
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: KPF
Approval Logo
Certificates
VDE Approvals
UL Approvals
Certification Body
VDE
UL
Description
VDE Certificate Number: 104869
UL File Number: E72928
EMC Products
1
KPF
Product standards
Product standards that are referenced
Organization
Design
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Standard
IEC 60320-1
IEC 60939
IEC 61058-1
UL 498
UL 1283
CSA C22.2 no. 42
CSA C22.2 no. 8
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Description
Appliance couplers for household and similar general purposes
Passive filters for suppressing electromagnetic interference
Switches for appliances. Part 1. General requirements
Standard for Attachment Plugs and Receptacles
Electromagnetic interference filters
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Electromagnetic interference (EMI) filters
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Designed for applications acc.
Standard
IEC/UL 60950
IEC 60601-1
Description
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Suitable for use in medical equipment according to IEC/UL 60601-1
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
Medical Equipment
SCHURTER AG
Dimension [mm]
53.34
56.1
7.62
27.94
7.62 7.62
2
7.62
36.5
12.7
10.16
36
32
18.5
17.9
41.05
34.85
12.7
3.82
2
2.9
16.45
2
EMC Products
16.85
5.08
4.5
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
KPF
Drilling diagram
Layout to diagram A
53.34
27.94
7.62 7.62 7.62 7.62 12.7 10.16
Drilling diagram
Layout to diagram B
53.34
27.94
7.62 7.62 7.62 7.62 12.7 10.16
N’ L’ N
L
E
1
)
21.6
12.7
1
)
N’ L’ N
L
E
12.7
8.9
3.82
1.6
+0.1
0
(N’ L’ N
3.82
L E)
1.6
+0.1
0
(N’ L’ N
L E)
1) Minimum ground plane
1) Optimal ground plane
Technical Data of Filter-Components
Rated Current
[A]
1
2
4
6
8
10
1
2
4
6
8
10
Filter-Type
Standard Version
Standard Version
Standard Version
Standard Version
Standard Version
Standard Version
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Inductances
L [mH]
2 x 10
2x4
2 x 1.6
2x1
2 x 0.6
2 x 0.4
2 x 10
2x4
2 x 1.6
2x1
2 x 0.6
2 x 0.4
Capacitance
CX [nF]
100
100
100
100
100
100
100
100
100
100
100
100
Capacitance
CY [nF]
2.2
2.2
2.2
2.2
2.2
2.2
-
-
-
-
-
-
R [MΩ]
-
-
-
-
-
-
1
1
1
1
1
1
Diagrams
Standard line filter
EMI filtering of equipment emissions
A
L'
L1
Cy
Cx
Cy
L
2)
N
B
L
L1
Cy
Cy
L2
Cx
8.9
21.6
L'
2)
N'
1) PE
N'
1) PE
N
1) Line
2) Load
1) Line
2) Load
EMC Products
3
KPF
Attenuation Loss
Standard version
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
- - - - 50Ω differential mode _____ 50Ω common mode
1A
2A
4A
6A
8A
10 A
Medical version (M5)
1A
2A
4A
6A
8A
10 A
All Variants
Rated Current
[A]
Filter-Type
Order Number
1
2
4
6
8
10
1
2
4
6
8
10
Standard Version
Standard Version
Standard Version
Standard Version
Standard Version
Standard Version
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
Medical Version (M5)
KPF1.1
KPF2.1
KPF4.1
KPF6.1
KPF8.1
KPF0.1
KPF1.3
KPF2.3
KPF4.3
KPF6.3
KPF8.3
KPF0.3
Availability for all products can be searched real-time:https://www.
schurter.com/en/Stock-Check/Stock-Check-SCHURTER
4
EMC Products
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
KPF
Packaging unit
50 Pcs
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
EMC Products