Note: The actual product is marked differently from the
image shown here.
RoHS compliant
■
Application Examples
•
Semiconductor test equipment
•
Test & Measurement equipment
•
Communication equipment
•
Data loggers
■
Terminal Arrangement/Internal
Connections
4
3
416
OMRON mark
612
Model name
LOT.No.
1
2
Note: The actual product is marked differently from the image shown here.
■
List of Models
Package type
Contact form
Terminals
Load voltage
(peak value)
*
Model
G3VM-41LR4
SSOP4
1a
(SPST-NO)
Surface-mounting Terminals
40 V
G3VM-41LR4 (TR05)
G3VM-41LR4 (TR10)
G3VM-41LR4 (TR)
Note: Ask your OMRON representative for orders under 1,500 pcs, 1,000 pcs, or 500 pcs. We can supply products with the tape already cut.
Tape-cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them.
Refer to common precautions.
*
The AC peak and DC value are given for the load voltage.
Minimum package quantity
Number per tape and reel
-
500
1,000
1,500
■
Absolute Maximum Ratings
(Ta = 25
°C)
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Output
Input
Symbol
I
F
∆I
F
/°C
V
R
T
J
V
OFF
I
O
∆I
O
/°C
T
J
V
I-O
Ta
Tstg
-
Rating
50
−0.5
5
125
40
250
−2.5
125
1500
−20
to +85
−40
to +125
260
Unit
mA
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement conditions
Ta
≥
25
°C
Ta
≥
25
°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■
Electrical Characteristics
(Ta = 25
°C)
Item
Symbol Minimum Typical Maximum
LED forward voltage
V
F
1.0
1.15
1.3
Reverse current
I
R
-
-
10
Capacity between terminals
C
T
-
15
-
Trigger LED forward current
I
FT
-
-
4
Maximum resistance with output ON
R
ON
-
2
3
Current leakage when the relay is open
I
LEAK
-
-
1.0
Capacity between terminals
C
OFF
-
5
7
Capacity between I/O terminals
C
I-O
-
0.8
-
Insulation resistance between I/O terminals
R
I-O
1000
-
-
Turn-ON time
t
ON
-
0.12
0.5
Turn-OFF time
t
OFF
-
0.14
0.5
Unit
V
µA
pF
mA
Ω
nA
pF
pF
MΩ
ms
ms
Measurement conditions
Note: 2. Turn-ON and Turn-OFF Times
I
F
= 10 mA
I
F
1
V
R
= 5 V
4 R
L
V
DD
V = 0, f = 1 MHz
V
OUT
2
3
I
O
= 100 mA
I
F
= 5 mA, I
O
= 250 mA, t = 10 ms
V
OFF
= 30 V, Ta = 50
°C
V = 0, f = 100 MHz, t < 1 s
I
F
f = 1 MHz, V
S
= 0 V
V
I-O
= 500 VDC, R
O
H
≤
60 %
90%
V
OUT
10%
I
F
= 5 mA, R
L
= 200
Ω,
t
ON
t
OFF
V
DD
= 10 V (See note 2.)
Input
1
Output
G3VM-41LR4
■
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
Symbol
V
DD
I
F
I
O
Ta
Minimum
-
10
-
25
Typical
-
-
-
-
Maximum
32
30
250
60
Unit
V
mA
mA
°C
MOS FET Relays
■
Engineering Data
LED forward current vs. Ambient temperature
I
F
- Ta
Continuous load current I
O
(mA)
LED forward current I
F
(mA)
100
500
Continuous load current vs. Ambient temperature
I
O
- Ta
LED forward current vs. LED forward voltage
I
F
- V
F
LED forward current I
F
(mA)
100
50
30
10
5
3
Ta = 25
°C
80
400
60
300
40
200
1
20
100
0.5
0.3
0.1
0
-20
0
0
20
40
60
80
100
120
-20
0
20
40
60
80
100
120
0.6
0.8
1
1.2
1.4
1.6
1.8
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
LED forward voltage V
F
(V)
Continuous load current vs. On-state voltage
I
O
- V
ON
Continuous load current I
O
(mA)
300
Ta = 25
°C
I
F
= 5 mA
On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature
R
ON
- Ta
On-state resistance R
ON
(Ω)
Trigger LED forward current I
FT
(mA)
5
I
O
= 250 mA
I
F
= 5 mA
t<1s
5
I
O
= 100 mA
t<1s
I
FT
- Ta
200
4
4
100
3
3
0
2
2
-100
-200
1
1
-300
-1
-0.5
0
0.5
1
0
-20
0
20
40
60
80
100
0
-20
0
20
40
60
80
100
On-state voltage V
ON
(V)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs. LED forward current
t
ON
, t
OFF
- I
F
Turn ON, Turn OFF time t
ON
, t
OFF
(µs)
1000
Ta = 25
°C
V
DD
= 10 V, R
L
= 200
Ω
Turn ON, Turn OFF time vs. Ambient temperature
t
ON
, t
OFF
- Ta
Turn ON, Turn OFF time t
ON
, t
OFF
(µs)
300
V
DD
= 10 V,
R
L
= 200
Ω
I
F
= 10 mA
Current leakage vs. Load voltage
I
LEAK
- V
OFF
Current leakage I
LEAK
(pA)
15
Ta = 25
°C
300
250
100
t
OFF
200
10
150
t
OFF
30
100
5
10
t
ON
t
ON
50
3
1
10
100
0
-20
0
20
40
60
80
100
0
10
20
30
40
LED forward current I
F
(mA)
Ambient temperature Ta (°C)
Load voltage (V)
Output terminal capacitance vs. Load voltage
C
OFF
- V
OFF
Output terminal capacitance C
OFF
/C
OFF
(0 V)
1
Ta = 25
°C
0.8
0.6
0.4
0.2
0
10
20
30
40
50
Load voltage (V)
■
Safety Precautions
•
Refer to
"Common Precautions"
for all G3VM models.
2
Appearance/Dimensions
■
Appearance
SSOP (Shrink Small Outline Package)
SSOP4
SSOP4 type
416
Model name
LOT.No.
OMRON mark
612
Note: The actual product is marked differently from the image shown here.
■
Dimensions
416
612
(Unit: mm)
Surface-mounting Terminals
Weight: 0.03 g
4.2
Actual Mounting Pad
Dimensions
(Recommended Value, TOP VIEW)
3.65
0.15
1.8
1.9
1.4 dia.
0.95 3.73
(0.3)
1.27
2.04
0.2
3.8
(0.46)
0.8
1.27
Unless otherwise specified, the
dimensional tolerance is ± 0.1 mm.
Note: The actual product is marked differently from the image shown here.
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.