MIL Series Connector, 19 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size11MB,12 Pages
ManufacturerEsterline Technologies Corporation
Environmental Compliance
Download Datasheet Parametric View All

MS3474L24-19P Online Shopping

Suppliers Part Number Price MOQ In stock  
MS3474L24-19P - - View Buy Now

MS3474L24-19P Overview

MIL Series Connector, 19 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,

MS3474L24-19P Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEsterline Technologies Corporation
Reach Compliance Codenot_compliant
ECCN codeEAR99
Other featuresSTANDARD: MIL-C-26482, POLARIZED, COMPATIBLE CONTACT: M39029/4-112
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationGOLD
Contact completed and terminatedGold (Au)
Contact point genderMALE
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Environmental characteristicsENVIRONMENT/FLUID RESISTANT
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size24
Termination typeCRIMP
Total number of contacts19
souriau
MIL-C 26482G Series II
Applications
For all general purposes in military
applications
Description
• Standard version
• Aluminium alloy
olive green, nickel or, black, anodized plating
• Bayonet coupling
• RFI shielding plug
• Gold plating crimp contacts # 20, 16,
and # 12
• # 16 and # 12 minicoaxial or thermocouple
contacts
• Hermetic version available
• Light weight backshells
Standards
MIL-C 26482 series II
QPL approved
Characteristics
Mechanical
• Endurance : 500 operations
• Plug MS 3475 : 250 operations.
• Plug MS 3476 : 500 operations.
• Shock : 300g - 3ms in three axes.
• Vibration : MIL STD 202, method 214, test
condition II, letter J (50 - 2000Hz; 41,7 g eff.)
• Contact retention in insert :
size 20 : 90 N - size 16 : 111N - size 12 : 133N
Electrical
• Max. current rating per contact
size 20
size 16
size 12
environmental class
7,5 A
13 A
23 A
hermetic class
5A
10 A
17 A
Climatical
• Operating temperature :
-55°C to + 200°C (class L)
-55°C to + 175°C (classes W and H)
• Damp heat : MIL STD 1344
method 1002 - Type II
• Salt spray :
class W : 500 hr
class L : 48 hr
• Leakage :
environmental version :
- when mated under a differential pressure
of 1,03 bar. air leakage is
3,6 mm
3
/ h.
- low pressure immersion : 33 mbar
hermetic version :
- differential pressure of 1 bar air'helium,
leakage is
2,8 mm
3
/ hr
• Contact resistance
size 20
size 16
size 12
environmental class
1
mΩ
0,55 mΩ
0,35 mΩ
hermetic class
7 mΩ
3,8 mΩ
2,4 mΩ
• Insulation resistance :
5000 MΩ at 500 Vdc
• Dielectric withstanding voltage
Service
at ground level
at 21000 m
I
1500 Vrms
375 Vrms
II
2300 Vrms
550 Vrms
Resistance to fluids
MIL. L 7808
MIL. L 23699
MIL. H 5606
Hydraulic fluids M 2 V
MIL. C 25769 diluted
MIL. A 8243
MIL. T 5624 (JP5)
MIL. G 3056
Solvents
• Shell continuity with plug MS 3475,
environmental receptacle
5 mΩ,
hermetic receptacle
50 mΩ
Ordering information
environmental connectors
basic series
shell type
3470
3474
3475
3476
class and plating
W
- olive green cadmium
L
- nickel
shell size
contact layout
- see table p 65
contact type
P
S
A
B
polarization
N
- normal ( not included in part number)
W, X, Y and Z
- see table p 66
-
-
-
-
male contact
female contact
less male contact
less female contact
8-10-12-14-16-18-20-22-24
- square flange receptacle
- jam nut receptacle
- RFI shielded plug
- plug
MS
3470
W
••
••
P
62
No MCU thyristor control design!
[font=宋体]In today's industrial control, the application of thyristor is more and more, it has many advantages, such as can realize the switch without contact, no sparks generated when high voltage and...
设计狂人 Industrial Control Electronics
Find gas sensor host computer software
As follows, methane gas sensor host computer monitoring software or similar function software, I wonder if any friends have it? Share it, I will be grateful...
suoma Sensor
Items that should be checked after PCB wiring is completed (reprinted)
[align=left]Items that should be checked after PCB wiring is completed[/font][/align][table] [tr][td=576][align=center][align=left]When a PCB is designed, it is necessary to check some relevant parts ...
yayasoso PCB Design
Can stm32F103 connect to 100M network?
Can stm32F103 connect to 100M network? Because the development board is 10M.The current project is to transmit some video data to various devices through the network (the devices are all STM32F103 CPU...
jumpingpig stm32/stm8
Are there any good EDA design tool manufacturers in China?
I know that most EDA giants are from foreign countries. Are there any good EDA design tool manufacturers in China?...
kernelkoder PCB Design
Problems with the zigbee protocol and the meter data protocol 645 being nested
Has anyone done a project that embeds the ZigBee protocol with the meter 645 protocol? Please help! !...
云淡风轻2011 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2765  535  1833  1155  1302  56  11  37  24  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号