EEWORLDEEWORLDEEWORLD

Part Number

Search

HCSS-20-T-02-01-N-RW

Description
Interconnection Device
CategoryThe connector    The connector   
File Size81KB,2 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

HCSS-20-T-02-01-N-RW Overview

Interconnection Device

HCSS-20-T-02-01-N-RW Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
FACTSHEET F-200 SUPPLEMENT
HCMD–07–S–03–02–T
.100" IDC CABLE STRIPS
Mates with:
TSW, MTSW, TST, EW,
BST, LCW, ZST, MTLW,
TSM
Features:
Low Profile
Skinny side locks
Dual beam contacts
Single & double row
High temp insulator
Odd lead counts
Customs our specialty
Easy assembly
Specifications:
HCSD, HCSS
Insulator Material:
Black Liquid Crystal Polymer
Flammability Rating:
UL 94V-O
Insulation Resistance:
5000 MΩ
Temperature Range:
-65°C to +80°C
Withstanding Voltage:
1000 VRMS @ 60 Hz
Contact:
Phosphor Bronze
Plating:
10µ" (0,25µm) on contact
area, 150µ" (3,81µm)
Sn on balance over
50µ" (1,27µm) Ni.
Current Rating:
1A
Contact Resistance:
10 mΩ max
Lead Size Range:
.024" (0,61mm) SQ to
.026" (0,66mm) SQ
Lead Insertion Depth:
.185" (4,70mm) to .250"
(6,35mm)
Insertion Force:
6 oz avg (1,67N) average with
.025" (0,64mm) SQ probe
Withdrawal Force:
3 oz avg (0,83N) average with
.025" (0,64mm) SQ probe
Wire:
28 AWG 7/36 stranded
Tinned Copper
Specifications:
HCMD, HCMS
Insulator Material:
Black Liquid Crystal Polymer
Flammability Rating:
UL 94V-O
Insulation Resistance:
5000 MΩ
Temperature Range:
-65°C to +80°C
Withstanding Voltage:
1000 VRMS @ 60 Hz
Terminal: Phosphor Bronze
Plating:
150µ" (3,81µm) Sn
over 50µ" (1,27µm) Ni
Current Rating:
1A
Wire:
28 AWG 7/36 stranded
Tinned Copper
Note:
IDC assemblies are
non-standard, non-returnable.
;;
;
;;
TYPE
STRIP
ROW OPTION
NO. PINS
PER ROW
HCMD, HCMS
HCSD, HCSS
END
ASSEMBLY
S
= Single
= Double
(Color coded cable
N/A for 31 thru 36
pins/row. See
–G option.)
D
–05, – 07, – 08, –10,
–12, –13, –15,
–17, –20, –25, –30,
–32, –36
(Call Samtec other sizes)
HCM
= Male Strip
–S
= Single End
No. of Positions x .100 (2,54)
+ .180 (4,57)
(3,30)
.130
(5,08)
.200
(7,87)
.310
REF
Socket or Male Plug on one end
(0,51)
.020
(3,05)
.120
–D
= Double End
(0,64)
.025
SQ
TYP
(2,54)
.100
Single
(HCMS)
Double
(HCMD)
(2,54)
.100
HCS
= Socket Strip
(3,30)
.130
No. of Positions x .100 (2,54)
+ .180 (4,57)
(5,08)
.200
Socket or Male Plug on each end
–T
= Transfer End
(9,53)
.375
REF
(2,54)
.100
(0,76)
.030
SQ. TYP.
Single
(HCSS)
(2,54)
.100
Double
(HCSD)
Male Plug on one end with socket on
other.
Begin part number with HCM.
SAMTEC USA
• Tel: 1-800-SAMTEC-9 or 812-944-6733 • Fax: 812-948-5047
SAMTEC UK
• Tel: 01236 739292 • Fax: 01236 727113
SAMTEC ASIA PACIFIC
• Tel: 65-745-5955 • Fax: 65-841-1502
SAMTEC GERMANY
• Tel: +49 (0) 89 / 89460-0 • Fax: +49 (0) 89 / 89460-299
SAMTEC FRANCE
• Tel: 01 60 95 06 60 • Fax: 01 60 95 06 61
SAMTEC ITALY
• Tel: 39 039 6890337 • Fax: 39 039 6890315
SAMTEC JAPAN
• Tel: 81-424-42-8318 • Fax: 81-424-42-8319
SAMTEC CHINA
• Tel: 86-21-5385-4089 • Fax: 86-21-5385-4047
SAMTEC TAIWAN
• Tel: (02) 2395-1677 • Fax: (02) 2395-1689
Due to technical progress, all designs, specifications and components are subject to change without notice.
Experts, please feel free to give me some advice.
Question: Why is U i1 the inverting input terminal and U i2 the same-direction input terminal? How to determine whether it is the inverting input terminal or the same-direction input terminal? Please ...
whwshiyuan1984 Analog electronics
What apps are electronic engineers using?
[b]1. MyScript Calculator[/b] [size=15px][font=微软雅黑, arial][color=#000000]In engineering calculations, it is inevitable to encounter many difficult formulas, but many general calculators cannot help y...
qwqwqw2088 Talking
Are there any friends who know PL\M? Let's talk.
Are there any friends who know PL\M and want to communicate with me? Can you please leave your QQ number?...
love2008 Embedded System
Complete LED Lighting System Design Guide
Complete LED lighting system design guide...
qwqwqw2088 Power technology
Ask about threading
I am looking at the thread part in wince programming. I would like to ask the experts where threads are often used in actual applications. I know what threads are, but because I am just learning and h...
evildoor Embedded System
Msp430 SPI module
I want to use msp430f149 to complete the communication between MCU and nrf905 wireless module. The nrf905 module uses SPI protocol. Problem description: For example, IIC, I only know how to implement ...
liuchang--- Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 814  1240  1551  1706  2348  17  25  32  35  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号