.085 in. (2.16mm)
Density
Miniature Ribbon
IDC, SUPERIBBON
TM
All-Plastic
■
■
■
■
■
■
■
■
■
■
Patented contact terminates Discrete Wire (loose or jacketed cable) without stripping or
soldering solid- and stranded-wire versions available.
All-plastic design reduces cost.
Available in plug and socket styles in 14, 24, 36, 50, and 64 position sizes.
Includes InstaLatch passive latch feature for automatic latching. Sockets are also available
without latches.
Available with .125" or #4-40 mounting holes. 50-position size plug also available to lock with
industry-standard Bail Latches.
Designed for panel mount, 180° (Top-Entry), or 90° (Standard) / 270° (Reverse) End-Entry
cable application.
I
ntegral Cable Clamp on End-Entry versions provides superior strain relief, even with
hood removed.
Full range of application tooling is available for termination, unlatching, etc. See page 6-54
for details.
UL Recognized - Files E170218 (UL1977), E130965 (UL1863).
CSA Approved - File LR31996-7.
F
EATURES
M
ATERIALS
Insulator:
Gray UL94V-0 rated glass-filled polyester, except where noted
Contact:
Copper alloy
Contact Plating:
select gold over 50µin. select nickel standard;
30µin. select gold over 50µin. select nickel available
where indicated
E
NVIRONMENTAL
Operating Temperature:
-40°C to +105°C
Shock:
50G Peak, per EIA Std. RS364, TP27, Condition A
Vibration:
3 cycles @ 10-55Hz in each of 3 axes per EIA Std. 364, TP28,
Condition A
Moisture Resistance:
Per EIA Std. RS364, TP31, Condition B, with Step
7B excluded
Voltage Rating:
Withstanding Voltage:
Contact Rating:
Contact Resistance:
500 VAC @ sea level; 125 VAC @ 70,000 ft.
1200 VAC RMS @ sea level, per EIA Std. RS364, TP20
5 Amps (4 Amps per CSA)
6 milliohms maximum, per EIA Std. RS364, TP6
E
LECTRICAL
Contact Resistance Change During Life Conditioning:
Resistance Change
Wire Size
24 AWG Solid
26 AWG Solid
26 AWG Stranded
28 AWG Stranded
Insulation Resistance:
(milliohms, max.)
0.5
0.5
2.0
5.0
5000 Megohms minimum initial;
1000 Megohms minimum after moisture
Call Toll Free: 1 (800) 323-9612
6-6
.085 in. (2.16mm)
Density
Miniature Ribbon
Mechanical Characteristics
Durability:
200 mating/unmating cycles
Mating / Unmating Forces:
Mating Force (max.)
with InstaLatches
Lb.
Kg
12
5.44
17
7.71
23
10.43
32
14.52
37
16.78
IDC, SUPERIBBON
TM
All-Plastic
Size
14
24
36
50
64
Unmating Force (min.)
without InstaLatches
Lb.
Kg
2
0.91
4
1.81
6
2.72
7
3.18
8
3.63
Termination:
Solid IDC versions terminate 22 AWG - 26 AWG solid wire;
Stranded IDC versions terminate 24 AWG - 28 AWG stranded wire;
Recommended Wire Insulation: soft PVC, .040" (1.02mm) max. OD
Wire Grip Strength (using recommended wire type):
Minimum Force
Lb.
Kg
7
3.42
5
2.44
5
2.44
Wire Size
24 AWG Solid
26 AWG Solid
26 AWG Stranded
6-7
Call Toll Free: 1 (800) 323-9612
.085 in. (2.16mm)
Density
Miniature Ribbon
Panel Mount
IDC, SUPERIBBON
TM
All-Plastic
Panel mount connectors provide signal I/O from a panel or system cabinet.
See pages 6-51 thru 6-53 for accessories such as wire restraints, panel clips, mounting screws, and dust covers
that make the use of Cinch SUPERIBBON connectors even more cost-effective in panel-mount applications.
Dimensions
A
Size
14
24
36
50
64
in
1.745
2.170
2.680
3.275
3.875
mm
44.32
55.12
68.07
83.19
98.43
in
1.417
1.842
2.352
2.947
3.542
B
mm
35.99
46.79
59.74
74.85
89.97
in
0.738
1.163
1.673
2.268
2.863
D
mm
18.75
29.54
42.49
57.61
72.72
6
Call Toll Free: 1 (800) 323-9612
6-8
.085 in. (2.16mm)
Density
Miniature Ribbon
IDC, SUPERIBBON
TM
All-Plastic
Ordering Information, Panel Mount
Plug, InstaLatching
Solid Wire
Commercial
30Au/Ni
97-12140-11
97-12140-11A
97-12240-11
97-12240-11A
97-12360-11
97-12360-11A
97-12500-11
97-12500-11A
97-12640-11
97-12640-11A
97-12140-01
97-12140-01A
97-12240-01
97-12240-01A
97-12360-01
97-12360-01A
97-12500-01
97-12500-01A
97-12640-01
97-12640-01A
Mount
.125 Hole
#4-40 Hole
Size
14
24
36
50
64
14
24
36
50
64
Socket
Solid Wire
Commercial
30Au/Ni
97-22140-11
97-22140-11A
97-22240-11
97-22240-11A
97-22360-11
97-22360-11A
97-22500-11
97-22500-11A
97-22640-11
97-22640-11A
97-22140-01
97-22140-01A
97-22240-01
97-22240-01A
97-22360-01
97-22360-01A
97-22500-01
97-22500-01A
97-22640-01
97-22640-01A
97-22140-12
97-22140-12A
97-22240-12
97-22240-12A
97-22360-12
97-22360-12A
97-22500-12
97-22500-12A
97-22640-12
97-22640-12A
97-22140-02
97-22140-02A
97-22240-02
97-22240-02A
97-22360-02
97-22360-02A
97-22500-02
97-22500-02A
97-22640-02
97-22640-02A
Latch Mount
.125 Hole
InstaLatches
#4-40 Hole
.125 Hole
No Latches
#4-40 Hole
Size
14
24
36
50
64
14
24
36
50
64
14
24
36
50
64
14
24
36
50
64
6
6-9
Call Toll Free: 1 (800) 323-9612
.085 in. (2.16mm)
Density
Miniature Ribbon
180° (Top-Entry) Cable
IDC, SUPERIBBON
TM
All-Plastic
Snap-on plastic top-entry hoods are available separately to
provide strain relief to a cable when one of the mounting/
latching options from page 6-9 fits your requirements. See
page 6-53 for details and ordering information for top-entry
all-plastic hoods.
For bail latching applications, a 50-position size top-entry
plug is available. It locks with industry-standard bail latches
for positive locking/unlocking without tools. It also locks with
InstaLatch latches for passive automatic latching.
For these products, insulator material is blue UL94V-0 rated
glass-filled polyester, and hood material is gray UL94V-0
rated glass-filled polyester.
2.566(65.18)
Ordering Information, 180° (Top-Entry) Cable Bail Latching Plug
Solid Wire
Large (.296
"
) Cable Opening
Small (.250
"
) Cable Opening
Commercial
30Au/Ni
Commercial
30Au/Ni
77-32500LP
77-32500LPA
77-32500SP
77-32500SPA
Size
50
90° (Standard) / 270° (Reverse) End-Entry Cable
End-Entry connectors include a hood and integral cable clamp for cable exit
from the end
of the connector.
•
•
The standard-orientation plug has the cable clamp on the position-1 end, and the
standard-orientation socket has the clamp on the high position end.
Cables may be extended end-to-end (i.e., “running cable”) by mating standard-
orientation plugs and sockets, or “doubled back” by mating a standard-orientation
connector with a reverse-orientation mate.
Cables may exit either direction on a cable-to-panel application by choosing
standard or reverse-orientation, depending on the desired direction of cable exit.
Pointed-nose versions of the standard-orientation, 50-position size are slightly
smaller than the square-end product and are suited to applications with limited
space such as bridging adapters, etc.
#4-40 versions include screws that are 3/4" long, suitable for locking directly to
the body of another connector. For locking to connectors panel-mounted with
screwlock hardware, shorter screws are required. See pages 6-51 thru 6-53 for
these and other accessories, such as dust covers.
Running Cable Application
•
•
•
6
Doubled-Back Cable Application
Call Toll Free: 1 (800) 323-9612
6-10