EEWORLDEEWORLDEEWORLD

Part Number

Search

D3V-21G4-3C4A

Description
Snap Acting/Limit Switch, SPST, Momentary, 21A, 8VDC, 5.6mm, Quick Connect Terminal, Simulated Roller Lever Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size1MB,14 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance  
Download Datasheet Parametric View All

D3V-21G4-3C4A Overview

Snap Acting/Limit Switch, SPST, Momentary, 21A, 8VDC, 5.6mm, Quick Connect Terminal, Simulated Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

D3V-21G4-3C4A Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke5.6 mm
Actuator typeSIMULATED ROLLER LEVER
body width10.3 mm
body height15.9 mm
Body length or diameter27.8 mm
Contact (AC) maximum rated R load21A@250VAC
Maximum contact current (AC)21 A
Maximum contact current (DC)21 A
Contact (DC) maximum rated R load21A@8VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)8 V
Electrical life50000 Cycle(s)
Manufacturer's serial numberD3V
Installation featuresPANEL MOUNT
Maximum operating force0.83 N
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
Maximum pre-travel4 mm
sealIP00
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
Miniature Basic Switch
D3V
Reliable Basic Switch with External Lever
• Available by 0.1 A, 6 A, 11 A, 16 A and 21 A models, all with
self-cleaning contacts. 0.1 A utilizes gold alloy crossbar
contacts for high reliability at low loads.
• Available with internally or externally fitted levers, and 2 fix-
ing positions for external levers.
• Conforms to EN61058-1 UL1054.
• Right-angle plunger option available in some models.
• RoHS Compliant.
Ordering Information
Model Number Legend
D3V-@@@@-@@@-@-@
1 2 3 4
5 6 7
8
9
6. Terminals
A:
Solder/quick-connect terminal (#187)
C2: Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
(optional without surge creepage tab flush around
terminals.)
7. Maximum Operating Force
5:
1.96 N {200 gf}
4A: 1.23 N {125 gf}
4:
0.98 N {100 gf}
3:
0.49 N {50 gf}
2:
0.25 N {25 gf}
Note:
These values are for the plunger models.
8. Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
9. Special Code
None: Standard
H:
High temperature (125° C)
E:
Special rating: 21 (8) A
T:
High temperature (200
°
C)
1. Ratings
21: 20 (4) A at 250 VAC
16: 16 (3) A at 250 VAC
11: 11 (3) A at 250 VAC
6:
6 (2) A at 250 VAC
01: 0.1 A at 125 VAC
2. Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
3. Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
4. Hinge Position
None: Internal/Far from plunger
M:
External/Far from plunger
K:
External/Near plunger
5. Contact Form
1:
SPDT
2:
SPST-NC
3:
SPST-NO
Miniature Basic Switch
D3V
1
DS18B20 temperature value processing VHDL program ask
Dear experts, I don't understand why the DS18B20 temperature value is divided by 1600 in the VHDL program that processes the BCD number. Why not divide by 1000? [font=Arial][size=9pt] [/size][/font][f...
日出东方 Embedded System
Analysis of an Active Power Factor Correction Circuit with Indirect Input Current Control
Abstract: A simple and practical active power factor correction circuit with indirect input current control is analyzed, and simulation and experimental results are given.Keywords: active power factor...
zbz0529 Industrial Control Electronics
【Video sharing】SMT patch process eng
Very exciting SMT patch process video...
zl_123 Talking
Kinetis-K40FreeRTOS_V7.1.0 transplantation learning record (Part 2)
2012-3-12Some settings about source insight1. Add color display of assembly language keywordsOption-Document Options- "C Source FIle" corresponding to the File filter add *.s2. Highlight settings in f...
bluehacker NXP MCU
[Help] What is the purpose of impulse withstand voltage test? What is the difference between it and surge?
Hello, everyone!The customer's wall-mounted charging pile equipment was damaged during a 5KV impulse voltage test. What is the purpose of this impulse voltage test? What are the voltages between which...
工程之力 Switching Power Supply Study Group
7-segment digital tube decoding driver and counter form a 24-hour timer
The 7-segment digital tube decoder driver and counter form a 24-hour timer. Here is an introduction to the 7-segment digital tube. See the figure below [img] http://www.51hei.com/UpFiles/Pic/chip/2008...
weigaole Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 673  199  161  1663  105  14  4  34  3  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号