EEWORLDEEWORLDEEWORLD

Part Number

Search

FN3110L-80/99

Description
Three Phase EMI Filter, 480V
CategoryAnalog mixed-signal IC    filter   
File Size116KB,2 Pages
ManufacturerSchaffner
Download Datasheet Parametric View All

FN3110L-80/99 Overview

Three Phase EMI Filter, 480V

FN3110L-80/99 Parametric

Parameter NameAttribute value
MakerSchaffner
Reach Compliance Codeunknown
CertificationUL; CSA; EN
filter typeTHREE PHASE EMI FILTER
high220 mm
high potential2100 V
Maximum leakage current71.5 mA
length379 mm
Manufacturer's serial numberFN3110
Installation typePANEL MOUNT
Maximum operating temperature100 °C
Minimum operating temperature-25 °C
physical sizeL379XB90XH220 (mm)
Rated current80 A
Rated voltage480 V
width90 mm
RFI-Filter for Regeneration Units
35 to 300A current ratings
Exceptional attenuation from 150kHz to 30MHz
Excellent saturation resistance
Suitable for regeneration of returning power (via line reactor)
Nennströme von 35 bis 300A
Hervorragende Einfügungsdämpfung von 150kHz bis 30MHz
Sehr hohe Sättigungsfestigkeit
Geeignet für Rückspeisebetrieb ins Netz (via Netzdrossel)
Courants de service de 35 à 300A
Excellente atténuation de 150kHz à 30MHz
Seuil de saturation élevé
Convient pour la récupération d’énergie (à travers une self de ligne)
FN 3100/FN 3110
Electrical schematic
L1
L2
L3
Cx
L
L1’
L2’
L3’
R
R
1
E
LINE
C
y
E
LOAD
Cx
1
Approvals
C
US
EN 133’200
IEC 60’939
FN 3100 up to 150A
Technical specifications
Max. operating voltage:
Operating frequency:
High potential test voltage (factory test):
Protection category:
Overload:
Temperature range:
Flammability corresponding to:
Design corresponding to:
Filter
FN 3100-series
520VAC @ 50°C
DC to 60Hz @ 50°C
P
E 3000VDC for 2 sec
P
P 2900VDC for 2 sec
IP20
4 times rated current at switch on, 1.5 times
rated current for 1 minute, once per hour
–25°C to +100°C
UL 94V-2
UL 1283, CSA22.2 No. 8 1986, EN 133200
Current rating
Leakage current
Power loss
FN 3110-series
480VAC @ 50°C
DC to 60Hz @ 50°C
P
E 2700VDC for 2 sec
P
P 2100VDC for 2 sec
IP20
4 times rated current at switch on, 1.5 times
rated current for 1 minute, once per hour
–25°C to +100°C
UL 94V-2
UL 1283, CSA22.2 No. 8 1986, EN 133200
I/O connections
Weight
@ 50°C (40°C)
A
FN
FN
FN
FN
FN
FN
FN
FN
3100
3100
3100
3100
3100
3100
3100
3100
35
50
80
110
150
200
230
300
50
80
33
34
35
35
40
40
40
99
52
35
35 (39.5)
50 (56.5)
80 (90.4)
110 (124.3)
150 (169.5)
200 (226)
230 (230)
300 (335)
50 (55)
80 (88)
400VAC/50Hz
mA
48.9
66.1
71.5
71.5
71.5
71.5
71.5
71.5
66.1
71.5
W
11.8
18
25.9
32.7
50.6
60
36.5
54
19.5
36.5
33
34
35
35
40
40
40
99
52
35
kg
2.3
3.4
5.3
5.4
8.5
9.1
9.2
11.8
2.7
4.4
FN 3110 –
FN 3110 –
Max. leakage under normal working conditions. Note: if two phases are interrupted, worst case leakage could reach 5.3 times higher levels.
210

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1921  221  298  485  512  39  5  6  10  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号