FN351H-50/33

Description
520V, 60 HZ, THREE PHASE EMI FILTER, ROHS COMPLIANT PACKAGE
CategoryAnalog mixed-signal IC    filter   
File Size270KB,5 Pages
ManufacturerSchaffner
Environmental Compliance  
Download Datasheet Parametric View All

FN351H-50/33 Overview

520V, 60 HZ, THREE PHASE EMI FILTER, ROHS COMPLIANT PACKAGE

FN351H-50/33 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSchaffner
Reach Compliance Codecompliant
Other featuresTERMINAL BLOCK OUTPUT CONNECTIONS
CertificationCSA; ENEC-14
filter typeTHREE PHASE EMI FILTER
high65 mm
high potential2250 V
Maximum leakage current32.7 mA
length200 mm
Manufacturer's serial numberFN351
Installation typePANEL MOUNT
working frequency60 Hz
Maximum operating temperature100 °C
Minimum operating temperature-25 °C
physical sizeL200.0XB120.0XH65.0 (mm)/L7.874XB4.724XH2.559 (inch)
Rated current57.7 A
Rated voltage520 V
DATASHEET
3-Phase Filters FN 351
General Purpose EMC Filter
EMC solution for industrial inverters and motor
drives
Rated currents from 8 to 280 A
Selectable voltage level of 440 V and 520 V
Compliant with IEC 60950
Approvals
High differential and common-mode attenuation
FN 351 up to 110 A FN 351H up to 110 A
Features and benefits
Broad range of power ratings for fast and
convenient filter selection
Available as 440 VAC (FN 351) and 520 VAC (FN
351H) versions for network-specific applications
FN 351 filters provide a broadband common and
differential-mode attenuation performance, which
remains available also when high interference levels
are present
Solid, touch-safe filter terminals contribute to overall
equipment safety and make the filters compliant
with IEC 60950
Introduced as one of the very first motor drive EMC
filters in the market, FN 351 has been widely
imitated and has success- fully proven its function
over more than 10 years
3x 440/250 VAC (FN 351)
3x 520/300 VAC (FN 351H)
dc to 60 Hz
8 to 280 A @ 40 °C
Technical specifications
Maximum continuous operating voltage
Operating frequency
Rated currents
Typical applications
Three-phase motor drives
Inverters and converters
UPS
Industrial automation equipment
SMPS
High potential test voltage
P –> E 2600 VDC for 2 sec (FN 351)
P –> P 1900 VDC for 2 sec (FN 351)
P –> E 2750 VDC for 2 sec (FN 351H)
Protection category
Overload capability
P –> P 2250 VDC for 2 sec (FN 351H)
IP20
Temperature range (operation and storage)
Flammability corresponding to
Design corresponding to
4x rated current at switch on,
1.5x rated current for 1 minute, once per hour
-25 °C to +85 °C (25/085/21) (FN 351)
-25 °C to +100 °C (25/100/21) (FN 351H)
General purpose three-phase filtering
Typical electrical schematic
MTBF @ 40°C/400V (Mil-HB-217F)
UL 94 V-2 or better
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
135,000 hours
Good opportunity! Software engineer in Canada with annual salary of 40,000 to 100,000 Canadian dollars
1. Senior animation special effects editor 2. Embedded software design 3. MIS software design 4. 2D and 3D multimedia software applications 5. Software product development 6. Communication software de...
fujike029 Embedded System
Books (AVR Microcontrollers)
AVR MCU Application Design. Published by Beijing University of Aeronautics and Astronautics Press....
ptwang Microchip MCU
New here, please tell me about the company’s New Year’s Day benefits.
New here, everyone, tell me about the company's New Year's Day benefits. Our company doesn't make adjustments to holidays, so we only have one day off on New Year's Day, which I like better. Adjustmen...
longreen01 Talking about work
Chapter 10 Composite Equipment
Written by Ogawa Studio, this book is written for the LM3S USB chip. The uploaded ones are all drafts and have not been revised . There may be many shortcomings. I hope netizens will forgive me! QQ:26...
paulhyde Microcontroller MCU
My blog is gone
I often feel a little weird recently. I often post blogs, but when I check again, they are gone. I don’t know who is managing this. Did they delete it? It’s really hard to understand. I post useful th...
EMC13590301687 Talking about work
Improvement of online detection method of battery remaining capacity under high noise conditions
Abstract: Firstly, the shortcomings of several traditional methods for detecting the remaining capacity of batteries are pointed out: large limitations, difficult calculations, and great impact on the...
zbz0529 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 797  1015  688  810  268  17  21  14  6  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号