KBP301
Features
a
a
a
a
a
THRU
KBP307
Voltage Range 50 to 1000 Volts Current 3.0 Amperes
KBP
UL Recognized File # E-96005
Ideal for printed circuit board
Reliable low cost construction technique
results in inexpensive product
High temperature soldering guaranteed:
250°C / 10 seconds at 5 lbs. ( 2.3 Kg )
tension
Small size, simple installation
Leads solderable per MIL-STD-202,
Method 208
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
KBP
KBP
KBP
KBP
Type Number
301
302
303
304
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
@T
A
= 50°C
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated Load
(JEDEC method )
Maximum Instantaneous Forward Voltage
@ 3.14A
Maximum DC Reverse Current @ T
A
=25°C
at Rated DC Blocking Voltage @ T
A
=125°C
Typical Thermal Resistance (Note 1) RÛJA
Typical Thermal Resistance (Note 1)
RÛJL
Operating Temperature Range T
J
Storage Temperature Range T
STG
KBP
305
KBP
306
KBP
307
Units
V
V
V
A
A
V
uA
uA
°C/w
°C
°C
50
35
50
100
70
100
200
140
200
400
280
400
3.0
80
1.1
600
420
600
800
560
800
1000
700
1000
10
500
30.0
11
-55 to +150
-55 to +150
Web Site:
WWW.PS-PFS.COM
1/2
RATINGS AND CHARACTERISTIC CURVES (KBP301G THRU KBP307G)
FIG.1- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT PER BRIDGE ELEMENT
4.0
80
FIG.2- MAXIMUM FORWARD CURRENT DERATING
CURVE
AVERAGE FORWARD CURRENT. (A)
PEAK FORWARD SURGE CURRENT. (A)
70
60
50
3.0
2.0
40
30
20
1
1.0
2
4
6
10
20
40
60
100
0
20
40
60
80
100
o
120
140 150
NUMBER OF CYCLES AT 60Hz
AMBIENT TEMPERATURE. ( C)
FIG.3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER BRIDGE ELEMENT
10.0
FIG.4- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
100
INSTANTANEOUS FORWARD CURRENT. (A)
1.0
INSTANTANEOUS REVERSE CURRENT. ( A)
TJ=125
0
C
10
0.1
1
TJ=25
0
C
.01
.6
Tj=25 C
PULSE WIDTH-300 S
1% DUTY CYCLE
.7
.8
.9
1.0
1.1
1.2
1.3
1.4
0
0.1
0
20
40
60
80
100
120
140
INSTANTANEOUS FORWARD VOLTAGE. (V)
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
Web Site:
WWW.PS-PFS.COM
2/2