This document was generated on 05/18/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMA
Part Number:
Status:
Description:
Documents:
Drawing (PDF)
1120115028
Active
Direct-Link™ PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x
RoHS Certificate of Compliance (PDF)
General
Product Family
Series
Approvals
Comments
Communication Speed
MAC Address
Mounting Style
Product Name
Protocol
Type
Network Interface
112011
CE
Profibus DP-V0 (Master & Slave). . PROFIBUS DP-V1
(Master)
Profibus: 9.6 kbps to 12 Mbps
N/A
N/A
Direct-Link®
Profibus* DP
Profibus* Card
EU RoHS
ELV and
Complia
REACH S
Not Revi
Halogen
Status
Not Revi
Need mo
environm
Email pro
For a mu
Complian
Please vi
non-prod
Physical
Channels
Interface
Network Connection Type
Packaging Type
Processor
Temperature Range - Operating
1
Profibus*
D-Sub Female (9 pin)
Individual Carton
AMD SC520
0°C to +65°C
Search
112011
Electrical
Current - Maximum Input
EMC
Supply Voltage
5.5W
EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, IEC
61000-6-2
3.3V
Material Info
Old Part Number
DRL-DPM-PCIE
Reference - Drawing Numbers
Sales Drawing
SD-112011-0008
This document was generated on 05/18/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMA
BradCommunications™ Direct-Link
™
Profibus-DP network
interface cards allow deterministic I/O data acquisition
for PC-based control applications.
27 Jan. 10
DW200591
Direct-Link™ Profibus-DP
Features
•
NEW! RoHS compliant
•
Connect PC-Based Control
applications directly to I/O
devices
Data acquisition for real time Control applications
•
Protocols supported:
Profibus-DP V0 Master/Slave
Class-1 & 2
Profibus-DP V1 Master Class-1 &
2 (for PCI-Universal card only)
Profibus-DP Slave passive
PCI-Universal
PCI Express
PC/104
•
Available in various card form
factor: PC/104, PCI-Universal and
CompactPCI 3U
CompactPCI
Overview
BradCommunications™ Direct-Link™ is a low range of automation components for
industrial communication. It includes a variety of products such as diagnostic tools,
intelligent connectors, tunneling gateways, fieldbuses network interface cards, and
software drivers for industrial networks.
Simple as they are affordable, BradCommunications™ Direct-Link™ products allow
you to acquire the equipment to develop your architectures and industrial
applications at a lower cost.
Direct-Link™ products are characterized by their simple use and fast
implementation; they are modular and scalable. Moreover, they are designed to be
easily embedded into computerized systems and are available in a wide selection
of form factors.
•
1 Serial or Ethernet port for
remote configuration
and diagnostic
•
Automatic devices detection on
the network
•
Embedded Communication on
the card for powerful data
throughput
•
Configuration stored in the device
(Flash memory), with auto boot
mode
Powerful Network Interface card
Particularly, the
BradCommunications™ Direct-Link™ Profibus-DP
interface
cards are equipped with 1 Profibus port handling Profibus protocol in
Master
and/or Slave modes
up to 12 Mbps.
A smart A.D.M (Automatic Dual port ram Mapping) mechanism avoids the I/O tags
configuration in the Dual Port RAM of the card. More than a simple I/O acquisition
card, the Direct-Link™ interface cards provide the applications with additional
information such as:
device status and diagnostics, process data read/write
monitoring, communication tools for troubleshooting, hardware and software
Watchdog, etc..
The communication layers are completely embedded on the cards, allowing easy
and fast communication with field devices resulting in remarkable application
performance.
Product package includes:
Graphical console for configuration and diagnostic tools
Data servers (Multi-protocol OPC DA 3.0 & 2.05, ActiveX, DAServer,
FastDDE/SuiteLink)
I/O libraries for Windows (DLL) and Ardence's hard real time extensions
(RTX)
Static library for non-windows OS
Drivers for soft-logic packages
OS supported
Standard package
•
Windows 32-bit (XP SP1/ 2000 SP4 /
NT SP6, 2003 Server), Ardence
RTX
Free Download
•
Windows XP Embedded, QNX,
VxWorks, Linux, Phar Lap ETS,
DOS
Woodhead is a member of PTO (PROFIBUS
Trade Organization), PNO (PROFIBUS
Nutzerorganisation e. V.) and France
Profibus.
Technical data
Direct-Link™
PCU-DPIO
Direct-Link™
PCIE-DPIO
Key Benefits
•
Fast data exchange (on-board processor take off the load of the host CPU)
•
Speed up to 12 Mbps
•
Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS
•
DP-V0 Master Class 1 & 2/Slave simultaneously
•
DP-V1 Master Class 1 & 2
Hardware
Unit
Processor
Profibus ASIC
Memory
Flash Memory
Interruption
DPRAM Address
Discrete Input
Discrete Output
Dimensions (LxW)
Consumption
Operating T°
Storage T°
EMC Compliance
RoHS Compliance
Communication port
Port type
Connector
LED Indicator
Electrical Interface
Baud Rate
Port Type
Connector type
LED indicators
Electrical interface
Speed
1 Profibus port (EN 50170)
Profibus D-Sub, 9 pin, female
2 bicolor Leds: bus fault and communication status
RS485 optical insulation (500 V)
9.6 kbps
↔
12 Mbps
1 Profibus port (EN 50170)
Profibus D-Sub, 9 pin, female
2 bicolor Leds: bus fault and communication status
RS485 optical insulation (500 V)
9.6 kbps
↔
12 Mbps
PCI-Universal 3.3/5V, PCI-X compatible
AMD SC520, 133 Mhz
UART High Speed
16 Mbytes SDRAM
4 Mbytes
Hardware Plug&Play
Hardware Plug&Play (32 Kbytes)
1 x Opto-coupled discrete input,
Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
168mm x 107mm (6.61" x 4.21")
5.5W (max. 1.2A)
0ºC (32ºF) up to +65°C (149°F)
-40º C (-40°F) up to +85ºC (185º F)
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
YES
PCI Express 1x
AMD SC520, 133 Mhz
UART High Speed
16 Mbytes SDRAM
4 Mbytes
Hardware Plug&Play
Hardware Plug&Play (32 Kbytes)
1 x Opto-coupled discrete input,
Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
168mm x 107mm (6.61" x 4.21")
5.5W (max. 1.2A)
0ºC (32ºF) up to +65°C (149°F)
-40º C (-40°F) up to +85ºC (185º F)
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
YES
Port for remote configuration and diagnostic
Ethernet port
RJ45
4 Leds - TX/RX/Link/100 Mbps
Ethernet
10/100 Mbps
Ethernet port
RJ45
4 Leds - TX/RX/Link/100 Mbps
Ethernet
10/100 Mbps
Technical data
Direct-Link™
PC104-DPIO
Direct-Link™
CPCI-DPIO
Key Benefits
•
Fast data exchange (on-board processor take off the load of the host CPU)
•
Speed up to 12 Mbps
•
Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS
•
DP-V0 Master Class 1 & 2/ Slave simultaneously
Hardware
Unit
Processor
Profibus ASIC
Memory
Flash Memory
Interruption
DPRAM Address
Discrete Input
Discrete Output
Dimensions (LxW)
Consumption
Operating T°
Storage T°
EMC Compliance
RoHS Compliance
Communication port
Port type
Connector
LED Indicator
Electrical Interface
Baud Rate
Port Type
Connector type
LED indicators
Electrical interface
Speed
1 Profibus port (EN 50170)
In standard: HE13 (2 x 5 pins) or in option: 9-pin, Sub-
D, female
2 bicolor Leds: bus fault and communication status
RS485 optical insulation (500 V)
9.6 kbps
↔
12 Mbps
1 Profibus port (EN 50170)
Profibus D-Sub, 9 pin, female
2 bicolor Leds: bus fault and communication status
RS485 optical insulation (500 V)
9.6 kbps
↔
12 Mbps
PC/104 bus
AMD SC520, 100 Mhz
ASPC2
8 Mbytes SDRAM
512 Kbytes
2, 3, 4, 5, 6, 7, 10, 11, 12, 14, 15
From C8000 to DE000 (8 Kbytes used per card)
1 x Opto-coupled discrete input,
Voltage -> +10 to +30V DC or 24V AC (50-60 Hz)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
95mm x 90mm (3.74" x 3.54")
5.5W (max. 1.2A)
0ºC (32°F) up to +65ºC (149ºF)
-40º C (-40°F) up to +85ºC (185º F)
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
NO
CompactPCI bus, 5V
AMD SC520, 133 Mhz
ASPC2
8 Mbytes SDRAM
512 kbytes
Hardware Plug&Play
Hardware Plug&Play (16 Kbytes)
1 x Opto-coupled discrete input,
Voltage -> +10 to +30V DC or 24V AC (50-60 Hz)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
100mm x 160mm (3.93" x 6.29") - 3U
5,5W (max. 1.2A)
0º C (32º F)
↔
+65º C (149º F)
-40º C (-40°F) up to +85ºC (185º F)
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
YES
Port for remote configuration and diagnostic
Asynchronous Serial port
HE13 (2 x 5 pins)
-
RS232 – 2 signals
9600, 38400, 115200 bps
Asynchronous Serial port
9-pin, Sub-D, male
2 Leds - TX/RX
RS232 – 2 signals
9600, 38400, 115200 bps
Direct-Link™ Profibus-DP
Protocol Specifications
All BradCommunications™ Direct-Link™ networks interface cards for Profibus-DP support following protocols:
DP-V0 Master/Scanner Class-1 & -2 and Slave modes simultaneously
DP-V0 Slave passive mode only
DP-V1 Master Class-1 & -2
(for PCU card)
DP Master features
Access Modes
DPV0 Master/Scanner Class-1
for optimized exchange of input/output data with the slaves
(Data_Exchange).
DP-V0 Master Class-2
for:
Slave diagnostics
Reading inputs/outputs of a slave
Reading configuration data
Changing the slave address.
DP-V1 Master Class-1 & -2:
Read Data Block Class 1
Write Data Block Class 1
Read Data Block Class 2
Write Data Block Class 2
Abort Data Block Comm Class 2
Multi-master mode
Watchdog control
Input/Output Data
Yes (able to share the bus with other DP masters connected on the network)
Yes, enables the master to switch into error if no data has been exchanged during this period
(Bus Fault)
Memory of I/O data image:
o
PC/104:
up to 2Kbytes
o
PCI-Universal: up to 8Kbytes
o
PCI Express:
up to 8Kbytes
o
CompactPCI:
up to 4Kbytes
Manage up to 244 data bytes per slave
Automatic organization of I/O data in the DPRAM memory
Max. DP Slave
Data consistency
Data format
Local DP slave
Connect up to 126 slaves
Yes (i.e. user gets the data up to 122 bytes of a slave from one and the same DP cycle)
Direct access to variable types (bit, byte, word, double word)
Run simultaneously with Master modes.
Offers data exchange with another master on the network. The size of the input and output data
is user-definable, and all exchange combinations are possible (from 0 to 244 bytes). The slave
can ensure data consistency up to 122 bytes. (see DP-Slave features below for details).
DP Slave passive features
Access Mode
Input memory size
Output memory size
Slave address
GSD files
Data Format
Address Assignment
Master
(Set_Slave_Address)
Extended Diagnostic
DP-V0 Slave passive (no management of Profibus token)
Configurable from 0 to 244 bytes
Configurable from 0 to 244 bytes
Configurable from 0 to 126 by software configuration
Provided on the CD-Rom
Configurable Intel or Motorola
Not supported
Not supported