EEWORLDEEWORLDEEWORLD

Part Number

Search

801-009-02ZN8-13GB

Description
Circular Connector, 13 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size317KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

801-009-02ZN8-13GB Overview

Circular Connector, 13 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,

801-009-02ZN8-13GB Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typePANEL
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE
Shell materialALUMINUM ALLOY
Housing size8
Termination typeCRIMP
Total number of contacts13
A
B
C
D
E
F
G
H
J
K
L
-07
Jam Nut for Rear
M
© 2007 Glenair, Inc.
Series 801
Series 801 “Mighty Mouse”
Double-Start ACME Thread
Series 801 Receptacles – Crimp Termination
In-Line
801-009-01
Rear Panel Jam Nut Mount
801-009-07
Square Flange Mount
801-009-02
Integral Band Platform
for direct attachment of a cable
shield using a
BAND-IT®
strap. Install a boot, or overmold
onto the band platform. An accessory thread is available
for attaching strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for rear panel
mounting, square flange or in-line receptacle for free-hanging
cables.
HOW TO ORDER
Sample Part Number
80 1- 0 1 0
Series
-02
Shell Style
Z1
Shell Material /
Finish
C
Aluminum / Black
Anodize
16-5 5
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
13-2
13-37
16-55
17-85
3 #23
1 #16
4 #23
7 #23
1 #12
10 #23
13 #23
4 #16
19 #23
26 #23
2 #12
37 #23
55 #23
85 #23
S
Contact Type
A
Shell Key
Position
M
801-009
Receptacle with
Banding Platform
-01
In-Line
Aluminum / Electroless
Nickel
Standard #23 contacts
A
accept #22 through
Normal
#28 AWG wire. Use the
following contact codes
to specify these contacts: Alternate Key
Positions:
P
Pin
NF
Aluminum / Cadmium
with Olive Drab
Chromate
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
B
C
D
ZN
801-010
Receptacle with
Accessory Thread
-02
Square Flange
for Front or Rear
Mounting
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
D-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Who has a design report for a digital ammeter based on a microcontroller?
I just need the circuit schematic and C source code. I would like to thank you! Or can anyone help me change the voltage meter program into an ammeter program: #includeunsigned char code dispbitcode[]...
ytada Embedded System
ARM9-compatible soft-core processor design: based on FPGA
"ARM9-Compatible Soft-Core Processor Design: Based on FPGA" introduces how to use the hardware description language Verilog for FPGA design. By reading this book, readers can design a 32-bit RISC arch...
arui1999 Robotics Development
51 MCU C language development detailed explanation very good introductory book
This book goes from the basics to the complex, has rich examples, and is easy to understand. It is a very good introductory book.This book has not been reprinted since the first edition. The original ...
hookyy 51mcu
2440 Reading the temperature chip always fails to trigger an interrupt. Is there any way to do this?
Calling the IIC folder through the application layer in the BSP package does not work properly, so I have to switch to the bootloader layer to do temperature detection, but the interrupt cannot be tri...
gonglee Embedded System
Please advise on the dual gate tube that can replace 3sk318
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:56[/i] I would like to ask all the experts, what type of dual-gate tube can replace 3SK318 (direct replacement is best) Thank you!...
dreamsky11 Mobile and portable
A book on playing FPGA in simple terms
A book on playing FPGA in simple termsEveryone knows it well, I don’t need to introduce it!...
xhk_hlju FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2282  1087  2283  2826  581  46  22  57  12  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号