EEWORLDEEWORLDEEWORLD

Part Number

Search

LP49-44-FREQ1-30J1CG

Description
Parallel - Fundamental Quartz Crystal, 3MHz Min, 4MHz Max, ROHS COMPLIANT PACKAGE-2
CategoryPassive components    Crystal/resonator   
File Size92KB,6 Pages
ManufacturerPletronics
Environmental Compliance  
Download Datasheet Parametric View All

LP49-44-FREQ1-30J1CG Overview

Parallel - Fundamental Quartz Crystal, 3MHz Min, 4MHz Max, ROHS COMPLIANT PACKAGE-2

LP49-44-FREQ1-30J1CG Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPletronics
package instructionROHS COMPLIANT PACKAGE-2
Reach Compliance Codecompliant
Other featuresAT-CUT CRYSTAL; BULK
Ageing5 PPM/YEAR
Crystal/Resonator TypePARALLEL - FUNDAMENTAL
Drive level1000 µW
frequency stability0.01%
frequency tolerance30 ppm
JESD-609 codee3
load capacitance44 pF
Manufacturer's serial numberLP49
Installation featuresTHROUGH HOLE MOUNT
Maximum operating frequency4 MHz
Minimum operating frequency3 MHz
Maximum operating temperature70 °C
Minimum operating temperature
physical sizeL10.8XB4.47XH3.56 (mm)/L0.425XB0.176XH0.14 (inch)
Series resistance200 Ω
surface mountNO
Terminal surfaceMatte Tin (Sn)
LP21 / LP24 / LP49 Series
Low Profile Crystal
February 2010
• The Pletronics’ LP49 Series is a low profile
thru-hole crystal
• Bulk packaging
• 3 MHz to 70 MHz
• HC-49/US
• AT Cut Crystal
LP21 0.082 (2.10mm) high
LP24 0.100 (2.50mm) high
LP49 0.140 (3.56mm) high
Pletronics Inc. certifies this device is in accordance with the
RoHS (2002/95/EC) and WEEE (2002/96/EC) directives.
Pletronics Inc. guarantees the device does not contain the following:
Cadmium, Hexavalent Chromium, Lead (<1000 ppm), Mercury, PBB’s, PBDE’s
Weight of the Device: 0.62 grams
Moisture Sensitivity Level: 1 As defined in J-STD-020C
Second Level Interconnect code: e1, e2 or e3
Electrical Specification:
Item
Frequency Range
Calibration Frequency Tolerance
Frequency Stability over OTR
Equivalent Series Resistance
(ESR)
Min
3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Drive Level
Shunt Capacitance
Aging per year
Specified Temperature Range
Storage Temperature Range
(C0)
-
-
-5
-40
-55
Max
70
-
-
200
150
120
100
80
70
60
50
40
35
100
80
60
1
7
+5
+85
+125
Unit
MHz
ppm
ppm
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
mW
pF
ppm
o
o
Condition
AT cut
at +25
o
C + 3
o
C
_
see table on page 3 for
available options
LP49
LP49/LP24
LP49/LP24
LP49/LP24
LP49/LP24
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
3
rd
Overtone
Fundamental
3 MHz to 4 MHz
4 MHz to 5 MHz
5 MHz to 6 MHz
6 MHz to 7 MHz
7 MHz to 9 MHz
9 MHz to 10 MHz
10 MHz to 13 MHz
13 MHz to 15 MHz
15 MHz to 27 MHz
27 MHz to 30 MHz
27 MHz to 32 MHz
32 MHz to 50 MHz
50 MHz to 70 MHz
use 10 µW for testing
Pad to Pad capacitance
at +25
o
C + 3
o
C
_
see table on page 3 for available options
C
C
Product information is current as of publication date. The product conforms
to specifications per the terms of the Pletronics limited warranty. Production
processsing does not necessarily include testing of all parameters.
Copyright © 2010, Pletronics Inc.
Continue with the portrait. This time it was taken on a windy day.
Hehehe, the wind was strong that day and the view was bright~...
银座水王 Talking
Ready to use, STM32L452 project of LPS22HH
Use NUCLEO-L452 evaluation board I2C1 to read LP22HH data and output it to computer display via UART2 STM32CubeMX builds the project, STMems StandardC official driverProject Files...
littleshrimp MEMS sensors
My ip6 was stolen early in the morning and it was turned off. What should I do?
[i=s]This post was last edited by Changjianze1 on 2016-11-11 11:28[/i] [size=5]What a tragedy[/size] [size=5]I took out my phone on the bus early in the morning[/size] [size=5]After getting off the bu...
常见泽1 Talking
Report---Sensor Section
I’m a new member of the sensor section. Please give me your advice!...
laoguo Suggestions & Announcements
The error of ADC10 collecting 1KHz sinusoidal signal is very large
[size=5] I posted my program, which is single-channel. It can measure DC signal, but the error of 800mv 1KHz sine signal is very large, and it only displays 0.1XX (XX is two numbers that change very q...
hpy168888 Microcontroller MCU
Are there any other solutions for syncing data?
We have been using Sqlce to synchronize data with the desktop sql database, but many users do not use sql databases, and the sqlce environment also occupies internal space, so I would like to ask ever...
sdsongge Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2841  1300  2786  306  251  58  27  57  7  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号