Embedded Power for
Business-Critical Continuity
NLP110 Series
Single and
triple output
Rev.04.05.08
NLP110 Series
1 of 4
Total Power:
80 - 110 W
Input Voltage:
90 - 264 Vac
# of Outputs:
Single, triple
Special Features
• Provides up to 10.5 A
on either 3.3 V or 5 V
• 5.5 x 3.0 inch card and
1.26 inch package
(1U applications)
• 3.3 V, 5 V and 12 V triple
• EN61000-3-2 compliant
• Overvoltage and
short circuit protection
• EN55022, EN55011
conducted emissions level B
• EN61000-4-2, -3, -4, -5, -6
immunity compliant
• Mounting holes as per
NLP65 series, easy upgrade
• Available RoHS compliant
• 2 year warranty
Electrical Specifications
Input
Input voltage range
Input frequency range
Input current
(cold start)
Safety ground
leakage current
Input current
120 Vac
230 Vac
120 Vac, 60 Hz
230 Vac, 50 Hz
120 Vac @ 80 W
120 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 110 W
UL/IEC127
Main output
Auxiliary outputs
At turn-on
Main output
75% to 100%
step at 0.1 A/μs
Main outputs
Cyclic operation
Single and multiple
Universal input,
(See Note 6)
90-264 Vac
47-63 Hz
18 A max.
35 A max.
0.45 mA
.75 mA
0.9 A rms
1.3 A rms
.48 A rms
0.7 A rms
F3.15 A H, 250 Vac
±2.0%
±5.0%
1.0 s, max
5.0% or 250 mV
max. dev., 1ms max.
recovery to 1%
±0.02%/°C
125%, ±10%
Continuous
See table
Input fuse
Output
Total regulation
(line and load)
Rise time
Transient response
Safety
VDE0805/EN60950/IEC950
File No. 10401-3336-1096
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062
Temperature coefficient
Overvoltage protection
Short circuit protection
Minimum output current
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
EMC Charateristics
(12)
Conducted emissions
Radiated emissions
Harmonic current
emission correction
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-3-2
EN61000-4-2
EN61000-4-2
EN61000-4-5
EN61000-4-4
EN61000-4-3
EN61000-4-6
Level B
Level A
Compliant
Level 3
Level 3
Level 3
Level 3
Level 3
Level 3
Rev.04.05.08
NLP110 Series
2 of 4
General Specifications
Hold-up time
Efficiency
Isolation voltage
Approvals and
standards pending
120 Vac, 60 Hz
120 Vac, 80 W (-9605J)
Input/output
Input/chassis
16.7 ms @ 110 W
75% min.
3000 Vac
1500 Vac
EN60950, VDE0805, IEC950,
UL1950, CSA C22.2 No. 950
283 g (10 oz)
MIL-HDBK-217F
220,000 hours min
Weight
MTBF demonstrated
Environmental Specifications
Thermal performance
Operating ambient,
(See derating curve)
Non-operating
50 °C to 70 °C ambient,
convection cooled
0 °C to 50 °C, ambient,
convection cooled
0 °C to 50 °C ambient,
150 LFM forced air
Peak (0 °C to +50 °C, 60 s)
Non-condensing
Operating
Non-operating
5-500 Hz
per MIL-STD-810E
0 °C to +50 °C
-40 °C to +85 °C
Derate to
50% load
80 W
110 W
(See Note 3)
5% to 95% RH
10,000 feet max
30,000 feet max
2.4 G rms peak
516.4 Part IV
DERATING CURVE
Output Power (Watts)
110W
80W
150 LFM FORCED
AIR COOLING
NATURAL
CONVECTION
COOLING
55W
40W
Relative humidity
Altitude
Vibration (see Note 5)
Shock
0C
10C 20C 30C 40C 50C 60C 70C
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
+5 V
+12 V
+48 V
+24 V
+5 V (A)
+3.3 V (B)
+12 V
+3.3 V (A)
+2.5 V (B)
+12 V
+12 V (A)
+3.3 V (B)
-12 V
+12 V (A)
+5 V (B)
-12 V
Min
(6)
0.5 A
0.3 A
0A
0.2 A
0.5 A
0.2 A
0A
0.5 A
0.1 A
0A
0.2 A
0.5 A
0A
0.2 A
0.2 A
0A
Max
(1)
15 A
6.4 A
1.6 A
3.2 A
13 A
13 A
0.65 A
13 A
13 A
0.65 A
6.5 A
13 A
0.65 A
6.5 A
13 A
0.65 A
150 LFM
(2)
22 A
9.2 A
2.3 A
4.6 A
16 A
16 A
1.0 A
16 A
16 A
1A
8.5 A
16 A
1A
8.5 A
16 A
1A
300 LFM
(3)
22 A
9.2 A
2.3 A
4.6 A
18 A
20 A
1A
20 A
20 A
1A
8.5 A
20 A
1A
8.5 A
18 A
1A
Peak
(4)
22 A
11.5 A
2.5 A
6.0 A
18 A
20 A
1A
22 A
22 A
1A
10 A
22 A
1A
10 A
22 A
1A
Ripple
(5)
50 mV
120 mV
240 mV
240 mV
50 mV
50 mV
120 mV
50 mV
50 mV
120 mV
1200 mV
50 mV
120 mV
120 mV
50 mV
120 mV
Total
Regulation
± 2.0%
± 2.0%
± 2.0%
± 2.0%
± 2.0%
± 2.0%
± 5.0%
± 2.0%
± 2.0%
± 5.0%
± 2.0%
± 2.0%
± 5.0%
± 2.0%
± 2.0%
± 5.0%
electronic test loads have a large delay time before they start drawing current
even though the voltage from the supply is present. During this time delay,
there is no load on the output and as a result, the supply cannot start-up
properly and maintain its correct output voltage. In these instances, a
dummy resistive load across the output may be necessary to load the output
of the supply until the test load can function correctly and draw the intended
minimum load. Minimum load required on auxiliary outputs to maintain
regulation.
For models NLP110-9608J and NLP110-9695J, the 12 V output is floating.
For -12 V output, pin 11 on J2 has to be connected to Return making pin 12
the -12 V output
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms
5 Hz to 500 Hz.
For optimum reliability, no part of the heatsink should exceed 110 ¼C, and
no semiconductor case temperature should exceed 120 ¼C.
CAUTION: Allow a minimum of 1 second after disconnecting line power when
making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
The EMI specifications reference measurements made with the power supply
mounted on a grounded metal sheet extending 1 inch beyond each edge,
using an unshielded cable. No external filtering required during conducted
emissions testing but some applications may require additional filtering to
achieve system compliance. A line choke, (ac input cords looped twice
through an EMI suppression toroid) was used during radiated emissions
testing. Considerable radiated testing in 1U six-sided boxes has shown that
units can meet level B in typical systems. Application support is available
from the factory to assist with EMI compliance.
All models require a minimum mounting stand-off of 6.35 mm (0.25 inches)
in the end use product.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.powerconversion.com/products.
NLP110-9608J
NLP110-9695J
NLP110-9694J
Model Numbers
(7, 14, 15)
NLP110-9605J
NLP110-9612J
NLP110-9617J
NLP110-9624J
NLP110-9693J
Rev.04.05.08
NLP110 Series
3 of 4
Notes
1
2
3
4
5
6
Free air convection.
Multiple output units: maximum continuous output power not to exceed 80 W.
For -9693J; I
3.3 V
= 13 A max.; I
5.0 V
= 13 A max.; I
3.3 V
+ I
5.0 V
² 16 A.
For -9694J; I
3.3 V
= 13 A max.; I
2.5 V
= 13 A max.; I
3.3 V
+ I
2.5 V
² 16 A
For -9695J; I
3.3 V
= 13 A max.; I
12 V
= 6.5 A max.; I
3.3 V
+ I
12 V
² 16 A.
For -9608J; I
5.0 V
= 13 A max.; I
12 V
= 6.5 A max.; I
5.0 V
+ I
12 V
² 16 A.
Single output units: maximum continuous output power not to exceed; 75 W
on -9605J; 76.8 W on -9612J,-9624J, and -9617J.
150 LFM forced air cooling from L4 side.
Multiple output units: maximum continuous output power not to exceed 105
W.
For -9693J; I
3.3 V
= 16 A max.; I
5.0 V
= 16 A max.; I
3.3 V
+ I
5.0 V
² 20 A.
For -9694J; I
3.3 V
= 16 A max.; I
2.5 V
= 16 A max.; I
3.3 V
+ I
2.5 V
² 20 A
For -9695J; I
3.3 V
= 16 A max.; I
12 V
= 8.5 A max.; I
3.3 V
+ I
12 V
² 20 A.
For -9608J; I
5.0 V
= 16 A max.; I
12 V
= 8.5 A max.; I
5.0 V
+ I
12 V
² 20 A.
Single output units: maximum continuous output power not to exceed 110 W
for all models.
300 LFM forced air cooling from L4 side.
Multiple output units: maximum continuous output power not to exceed 110
W.
For -9693J; I
3.3 V
= 20 A max.; I
5.0 V
= 18 A max.; I
3.3 V
+ I
5.0 V
² 22 A.
For -9694J; I
3.3 V
= 20 A max.; I
2.5 V
= 20 A max.; I
3.3 V
+ I
2.5 V
² 22 A
For -9695J; I
3.3 V
= 20 A max.; I
12 V
= 8.5 A max.; I
3.3 V
+ I
12 V
² 22 A.
For -9608J; I
5.0 V
= 20 A max.; I
12 V
= 8.5 A max.; I
5.0 V
+ I
12 V
² 22 A.
Single output units: maximum continuous output power not to exceed 110 W
for all models.
Peak output current lasting less than 30 seconds with duty cycle less than 5%.
During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6’ twisted pair,
terminated with a 10 μF electrolytic capacitor and a 0.1 μF ceramic capacitor.
Minimum load required for correct start-up and operation on single outputs
and on main output of multiple versions. Failure to observe minimum load
on main output will not allow the supply to start-up correctly. Some
7
8
9
10
11
12
13
14
15
Embedded Power for
Business-Critical Continuity
Americas
6.50
(165.10)
6.050
(153.670)
0.23
(5.842)
12
2.550
(64.770)
3.00
(76.20
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Rev.04.05.08
NLP110 Series
4 of 4
J4
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
J2
!
1
3
F1
J1
T1 (REF.)
J3
J5
2
1
1
1
2
Asia (HK)
0.23
(5.842)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
ALL DIMENSIONS IN INCHES (mm)
MAXIMUM COMPONENT HEIGHT
IS 1.26 (32.00)
Recommended direction
for forced air relative to
power supply orientation
shown below.
4
1
2
3
4
Optimum.
Very good.
Good.
Not recommended.
2
3
For global contact, visit:
1
Output Pin Connections
J2
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Single
No Connection
No Connection
No Connection
Return
Return
Return
Return
V (A)
V (A)
V (A)
No Connection
No Connection
Triple
V (B)
V (B)
V (B)
Return
Return
Return
Return
V (A)
V (A)
V (A)
V (C)
V (C) Return
(7)
Input Pin Connections
J1
Pin 1
AC Neutral
Pin 2
No Connection
Pin 3
AC Line
J3
Pin 1
V (A) Sense +
Pin 2
V (A) Sense -
J4
Pin 1
Safety Earth
J5
Pin 1
V (B) Sense +
Pin 2
V (B) Sense -
www.powerconversion.com
technicalsupport@
powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
Input and output connectors
AC (J1) connector type
Molex 26-60-4030 or equivalent.
DC (J2) connector type
12 position Molex Spox type 26-48
1125 or equivalent.
Sense (J3) connector type
Molex 22-23-2021 or equivalent.
Earth (J4) connector type
Male 0.250 quick disconnect.
Sense (J5) connector type
Leoco 2421P02H000.
Mating connectors
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex 08-50-0105
or equivalent crimp terminals.
DC (J2) mating connector type
Molex Spox type 26-03-3121 and contact 08-52-0113.
Sense (J3) mating connector type
Molex 22-01-3027 and contact 08-50-0113.
Earth (J4) mating connector type
Molex 90028.
Sense (J5) mating connector type
Leoco 2420S020000 and contact 2453TPB00V1.