EEWORLDEEWORLDEEWORLD

Part Number

Search

F.MG.03A.08.21.FA

Description
Mains Power Connector, 3A, 250V, Male, Solder Terminal, Plug, METAL PACKAGE-3
CategoryThe connector    The connector   
File Size737KB,3 Pages
ManufacturerNissei Electric Co.,Ltd.
Download Datasheet Parametric View All

F.MG.03A.08.21.FA Overview

Mains Power Connector, 3A, 250V, Male, Solder Terminal, Plug, METAL PACKAGE-3

F.MG.03A.08.21.FA Parametric

Parameter NameAttribute value
MakerNissei Electric Co.,Ltd.
package instructionMETAL PACKAGE-3
Reach Compliance Codeunknown
Other featuresSTANDARD: IEC/EN 60320, VDE, CSA
Body/casing typePLUG
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings3A, 250V
Manufacturer's serial numberF.MG
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
IEC Inlet Filters
With fuse holders and voltage selectors
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus input voltage selector
with 4 possible combinations. These features ensure the range is
ideally suited for manufacturers of business, consumer and medical
equipment for international markets.
F.MF-F.MG
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Voltage selector
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320, 1 (F.MF) or 2 (F.MG) fuse
holders for fuses 5 x 20mm (IEC) or 6.3 x 32mm
(US), voltage selector with 4 possible combinations;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 2.8 x 0.5mm for voltage selector terminals;
ground terminal connected to case.
F.MF.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MG. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MF.01A.01.01.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Voltage selector:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
110-220-240Vac
100-120-220-240Vac
115-115-230-230Vac
110-220Vac
Leakage current (I
L
):
at 220V, 50Hz, max value
F = 1 fuse
G = 2 fuses
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
01 = fuse 5 x 20mm + voltage selector 110-220-240V~
02 = fuse 5 x 20mm + voltage selector 100-120-220-240V~
03 = fuse 5 x 20mm + voltage selector 115-115-230-230V~
08 = fuse 6.3 x 32mm + voltage selector 110-220-240V~
09 = fuse 6.3 x 32mm + voltage selector 100-120-220-240V~
10 = fuse 6.3 x 32mm + voltage selector 115-115-230-230V~
15 = fuse 5 x 20mm + voltage selector 110-220V~
16 = fuse 6.3 x 32mm + voltage selector 110-220V~
19 = fuse 5 x 20mm + voltage selector 100-120-220-230V~
20 = fuse 6.3 x 32mm + voltage selector 100-120-230-240V~
21 = fuse 5 x 20mm + voltage selector 100-120-230-240V~
Approvals
29
How to cut board boundaries after upgrading AD14
In AD10, the first menu of Board Shape in Design can be used for cropping, but this AD14 does not work. When I crop, nothing is left. What should I do?...
cl17726 PCB Design
Problems with reading text files using CEdit controls
I want to make a text reader. I use memory mapped files to read text files, and then use CEdit controls to display them directly. But after displaying about 3,000 lines, no text can be displayed. The ...
pcbaggio Embedded System
Other motors in electric vehicle systems (Part 1)
[align=left][color=#000]When you hear EV (electric vehicle), you probably immediately think of a car speeding down the highway. But in reality, there are many different product categories for electric...
maylove Microcontroller MCU
I want to use LV as an oscilloscope
Does anyone want to make a digital oscilloscope using LV? I want to make one recently, please support me O(∩_∩)O~...
小宇 DIY/Open Source Hardware
Intelligent power monitoring and protection system Creative progress post + interval timer
Renesas' timers have their own characteristics. They are composed of TAU0, TMRJ0, TMRD0, TMRD1, and TMRG0. In addition to the general timing functions, these timers are also associated with some exter...
ltbytyn Renesas Electronics MCUs
An error occurred while generating NK.BIN. Please help me solve it.
Below is the error message Error: failed PB timebomb check makeimg: FATAL ERROR: Command returned non-zero exit code 1 (dec). makeimg: FATAL ERROR: Command returned non-zero exit code 1 (dec). BLDDEMO...
zhangzhenyuan Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2096  397  604  2061  787  43  8  13  42  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号