LK-P
10 A Slim Power Relay
VDE
LK-P
RELAYS
4. Popular terminal pitch in AV equip-
ment field
5. Space-saving slim type
Base area: Width 11
×
Length 24 mm
Width .433
×
Length .945 inch
6. Conforms to the various safety stan-
dards
UL/CSA, VDE, TÜV and SEMKO, SEV
approved
FEATURES
24.0
.945
11.0
.433
25.0
.984
mm
inch
1. High switching capacity: 10 A 277V AC
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch
(In compliance with IEC65)
2) Surge withstand voltage between contact
and coil: 10,000 V or more
3. High noise immunity realized by the
card separation structure between con-
tact and coil
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
1 Form A
Max. 100 m
Ω
Silver alloy
Characteristics
Max. operating speed
Initial insulation resistance*
1
Between open
Initial *
2
contacts
breakdown
Between contact and
voltage
coil
Initial surge voltage between contact
and coil*
3
Operate time*
4
(at nominal voltage)
Release time (without diode)*
(at nominal voltage)
Temperature rise (at 70
°
C)
Functional*
5
Destructive*
6
Functional*
7
Vibration resistance
Destructive
Conditions for operation,
transport and storage*
8
(Not freezing and con-
densing at low tempera-
ture)
Unit weight
Ambient
temp.
Humidity
Air
pressure
4
20 cpm (at rated load)
Min. 1,000 M
Ω
(at 500 V DC)
1,000 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V
Approx. 7 ms (at 20
°
C
68
°
F)
Approx. 2 ms (at 20
°
C
68
°
F)
Max. 45
°
C with nominal coil
voltage and at 10 A contact
carrying current
(resistance method)
Min. 200 m/s
2
{approx. 20 G}
Min. 1,000 m/s
2
{approx. 100 G}
10 to 55Hz
at double amplitude of 1.5mm
10 to 55Hz
at double amplitude of 1.5mm
–40
°
C to +70
°
C
–40
°
F to +158
°
F
5 to 85% R.H.
86 to 106 kPa
Approx. 12 g
.42 oz
Rating
(resistive load)
Nominal switching
10 A 277 V AC, 5 A 30V DC
capacity
Max. switching power
2,770 V A, 150W
Max. switching
277 V AC, 30 V DC
voltage
Max. switching
current
Mechanical
(at 180 cpm)
Electrical (at 20 cpm)
(at rated load)
10 A (AC), 5A (DC)
2
×
10
6
10
5
Expected life
(min. operations)
Coil
Nominal operating power
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of
±
1.2
×
50
µ
s according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10
µ
s
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10
µ
s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Shock resistance
530 mW
TYPICAL
APPLICATIONS
• Audio visual equipment
TVs, VTRs
• Office equipment
LBP, CRT
• Home appliances
Refrigerator, Air conditioner
ORDERING INFORMATION
Ex. LKP
Contact arrangement
1a: 1 Form A
1a
F
–
12V
Coil voltage(DC)
12, 24V
Protective construction
F: Flux-resistant type
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.
Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
2. 5 V, 9 V, 18 V DC types are also available. Please consult us for details.
56
LK-P
TYPES AND COIL DATA (at 20
°
C
68
°
F)
Part No.
LKP1aF-12V
LKP1aF-24V
Nominal
voltage,
V DC
12
24
Pick-up
voltage,
V DC (max.)
(Initial)
8.4
16.8
Drop-out
voltage,
V DC (min.)
(Initial)
1.2
2.4
Coil resistance,
Ω
(
±
10%)
272
1,087
Nominal
operating
current,
mA (
±
10%)
44.2
22.1
Nominal
operating power,
mW
530
530
Maximum
allowable
voltage,
V DC (at 20°C
68°F)
15.6
31.2
mm
inch
PC board pattern (Bottom view)
2-0.9 dia
2-.035 dia
16.5
.650
2-1.3 dia
2-.051 dia
7.5
.295
20.0
.787
4
.157
0.4
.016
1.0
.039
7.5
.295
20.0
.787
DIMENSIONS
Max. 25.0
.984
0.5
.020
0.5 dia.
.020 dia.
1.65
.065
0.3
.012
Max. 24.0
.945
16.5
.650
Tolerance:
±
0.1
±
.004
Schematic (Bottom view)
Max. 11.0
.433
Dimension:
Max. 1mm
.039 inch:
1 to 3mm
.039 to .118 inch:
Min. 3mm
.118 inch:
General tolerance
±
0.1
±
.004
±
0.2
±
.008
±
0.3
±
.012
REFERENCE DATA
1. Max. switching power
2. Coil temperature rise
Sample: LKP1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 5 A, 10 A
100
60
Coil applied voltage, %V
55
Temperature rise,
°C
Contact current, A
50
45
40
35
30
60
25
0
10
100
Contact voltage, V
20
0
100
120
Coil applied voltage, %V
20
0
10
20
Pick-up voltage
70°C 10A
70°C 5A
20°C 10A
20°C 5A
3. Ambient temperature characteristics and coil
applied voltage
Contact current: 10 A
220
180
Allowable ambient temperatures
against % coil voltages
(max. inside the coil tem-
perature set as
115°C
239°F)
10
140
100
Cold start
1
30
40
50
60
70
80
Ambient temperature,
°C
4. Life curve
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: room temperature
100
250V AC resistive load
Life,
×10
4
10
1
0
2
4
6
8
10
Contact current, A
57
LK-P
5. Electrical life test
(10 A 277 V AC, resistive load)
Sample: LKP1aF-12V, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20
°
C
68
°
F
Change of pick-up and drop-out voltage
12
Pick-up and drop-out voltage, V
10
Pick-up voltage
8
Max.
6
4
Drop-out voltage
2
0
0
Max.
x
Min.
5
No. of operations,
×10
4
10
x
Min.
Change of contact resistance
50
45
Contact resistance, mΩ
40
35
30
25
20
15
10
5
0
0
5
No. of operations,
×10
4
Min.
10
Max.
x
Circuit:
Contact
welding
detection
and Mis-
contacting
detection
circuit
277V AC
12V DC
For Cautions for Use, see Relay Technical Information (Page 11 to 39).
58