DC Solid State Relay
Part Number
Relay Description
Series KD/LD
DC
SHORT CIRCUIT PROTECTED OPTICALLY ISOLATED, 10A, 60 VDC
KD00CK
KD02CK
KD20CK
KD22CK
LD00CM
LD02CM
LD20CM
LD22CM
5 A Solid State Relay (SSR)
5 A SSR with Switch Status
5 A SSR with Short Circuit Protection
5 A SSR with Short Circuit Protection
and Switch Status
10 A Solid State Relay
10 A SSR with Switch Status
10 A SSR with Short Circuit Protection
10 A SSR with Short Circuit Protection
and Switch Status
FEATURES
• Available with short circuit/current
overload protection
• Available with switch status output
• TTL and CMOS compatible control
• Low ON resistance power FET
output
• Fast switching speed
• Meets 28 Vdc system requirements
of MIL-STD-704
• Optical isolation
• Low profile hermetic package
• Built and tested to the requirements
of MIL-R-28750
BD
* The Y suffix denotes parameters tested to MIL-R-28750 specifications.
The W suffix denotes parameters tested to Teledyne specifications.
ELECTRICAL SPECIFICATIONS
(-55°C TO +105°C UNLESS OTHERWISE NOTED)
INPUT (CONTROL) SPECIFICATION
When used in 2 terminal configuration
(TTL or direct control) (See Fig. 1)
Min
Typ
DESCRIPTION
The KD and LD series solid state
relays are screened utilizing MIL-R-
28750 test methods and are
packaged in low profile hermetically
sealed cases. These relays are
constructed with state-of-the-art solid
state techniques and feature fully
floating power FET output
technology. This allows the load to be
connected to either output terminal
and provides a low ON resistance.
The input (control) and output are
optically isolated to protect input logic
circuits from output transients.
Available options include short circuit
and current overload protection,
which provides complete protection
for both the relay and system wiring.
This feature not only provides
protection should a short or overload
occur while the relay is on, but will
also provide protection should the
relay be switched into a short. The
second option is a status output line.
Switch status returns the true status
of the output switch and is optically
isolated from the load. It provides
status indication independent of the
control circuit of the relay. The status
line provides a logic 0 (low) when the
relay output is off with load voltage
and continuity present, and a logic 1
(high) when the output is on. These
options are available either together
or separately as standard features.
AC
Max
Units
Input Current @ VBIAS = 5 Vdc (See Fig. 2)
Turn-Off Voltage (Guaranteed Off)
Turn-On Voltage (Guaranteed On)
Reverse Voltage Protection
Input Supply Range (See Note 1)
3.8
3.8
14
15
1.5
mAdc
Vdc
Vdc
-32
32
Vdc
Vdc
INPUT (CONTROL) SPECIFICATION
When used in 3 terminal configuration
(CMOS or open collector TTL) (See Fig. 1)
Min
Typ
DC
Max
Units
Control Current
VCONTROL = 5 Vdc
VCONTROL = 18 Vdc
250
1
0
3.8
14
3.2
0.3
18
32
16
µAdc
mAdc
Vdc
Vdc
mAdc
Vdc
Vdc
Control Voltage Range
Bias Supply Voltage (See Note 1)
Bias Supply Current
Turn-Off Voltage (Guaranteed Off)
Turn-On Voltage (Guaranteed On)
A
D
12/96
©1996 TELEDYNE RELAYS
DC-19
Series KD/LD
OUTPUT (LOAD) SPECIFICATIONS
Min
Typ
DC
(See Note 2)
BLOCK DIAGRAM
Max
Units
Continuous Load Current KD and LD series
(See Fig. 3)
without heat sink
LD series with
heat sink
Leakage Current
VLOAD=60Vdc
KD00CK, KD20CK
LD00CM, LD20CM
KD02CK, KD22CK
LD02CM, LD22CM
5
Adc
10
100
µA
2
mA
WITH STATUS
BD
Output Voltage
Drop
KD00CK, KD02CK
KD20CK, KD22CK
LD00CM, LD02CM
LD20CM, LD22CM
Continuous Operating Load Voltage
.60
.70
Vdc
1.2
1.4
60
80
.075
Vdc
Vdc
AC
Transient Blocking Voltage
ON Resistance
I
LOAD
= 100 mA
TJ = 25°C
(See Fig. 4)
Turn-On Time (See Fig. 5)
Turn-Off Time (See Fig. 5)
Electrical System Spike
KD00CK, KD20CK
LD00CM, LD20CM
KD20CK, KD22CK
LD20CM, LD22CM
NO STATUS
Ohms
.100
MECHANICAL SPECIFICATIONS
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
.200
±.010
5
2
±600
1600
10
ms
ms
Vpk
pF
0.188 ±.010
22
1
3
0.
0.60
0.140 DIA
(3.556)
6 PLS
Tolerance:
.XXX ± .005
16
9
12
1.000
(25.400) .040 (1.02)
± .002 (0.051)
0.8
6 PL
1.340
(34.04)
1.375
REF (34.925)
MAX
DC
Output Capacitance at 25 Vdc, 100 KHz
Isolation
(Input to Output)
KD00CK, KD20CK
LD00CM, LD20CM
KD02CK, KD22CK
LD02CM, LD22CM
Dielectric Strength
Insulation Resistance @ 500 Vdc
Output Junction Temperature
@ I
LOAD
= I
MAX RATED
Maximum Junction Temperature
Thermal Resistance Junction to Ambient (θJA)
Thermal Resistance Junction to Case (θJC)
1000
109
0.400
(10.160)
Tolerance:
.XXX ± .005
.475
±.015
0.801
(20.345)
MAX
0.81
MAX
.398
(10.1)
.551
(14.0)
0.22
(5.59)
MAX
K PACKAGE
K PACKAGE
pF
15
.157 (3.99) ±
.003 (.076)
DIA
THRU 2 PLS
.475
±.015
0.22
(5.59)
MAX
Vac
Ohms
130
°C
1.000
(25.4)
.200 (5.08)
.600
.800 (15.2)
(20.3)
A
1.750
± .002 (0.051)
6 PLS
(44.45)
2.105
(53.47)
MAX
.040 (1.02) DIA
1.370
REF
TEMPERATURE
MEASUREMENT POINT
150
30
7
°C
°C/W
°C/W
.140 (3.56)
DIA
6 PLS .200
(5.08)
L PACKAGE
L PACKAGE
.400 (10.2)
• Enclosure: Hermetically Sealed DIP
• Leak Rate: 1 x 10-8 CC/Sec Maximum
• Material:
Header:
Cold Rolled Steel
Nickel Plated
Copper Core
D
Pins
• Weight:
20 grams
• Tolerance: .XXX ± .005
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
DC-20
Series KD/LD
ENVIRONMENTAL SPECIFICATIONS
Temperature
Range
LOAD
VSTATUS
ISO
VSO
IBIAS
VBIAS
ICONTROL
CONTROL
3
RETURN
9
(-) OUTPUT
LOAD
DC
RSTATUS
RS
BIAS
22
1
IS
IT
STATUS
OUTPUT (+) OUTPUT
16
Operating
Storage
-55°C to +105°C
-55°C to +125°C
100 g, 10 to 3000 Hz
5000 g
1500 g, 0.5 ms pulse
12
VCONTROL
KD02CK
LD02CM
KD22CK
LD22CM
VLOAD
Vibration
Constant Acceleration
LOAD
RETURN
Shock
(A) 3 TERMINAL INPUT WITH STATUS (See Note 5)
STATUS OUTPUT TRUTH TABLE
RS
VIN
IIN
BIAS
22
CONTROL 1
3
RETURN
CONTROL
O.C. TTL
9
(-) OUTPUT
LOAD
(KD02CK, LD02CM, KD22CK, LD22CM)
LOAD
(+) OUTPUT
12
KD02CK
LD02CM
KD22CK
LD22CM
KD00CK
LD00CM
VLOAD
Control Voltage
Relay Output State
Status Output Level
BD
High
1/
LOAD
RETURN
Off
On
Low (VSO
≤
0.4 Vdc)
High (VSO = VSTATUS)
Low
(B) 2 TERMINAL INPUT (OPEN COLLECTOR TTL DRIVE)
VSTATUS
ISO
VSO
VIN
S1
STATUS OUTPUT SPECIFICATIONS
(KD02CK, LD02CM, KD22CK, LD22CM)
Min
Typ
Max
Units
AC
RSTATUS
IIN
BIAS
IS
IT
STATUS
OUTPUT
(+) OUTPUT
LOAD
Status Supply Voltage
Status Leakage Current @ 15 Vdc
VLOAD
KD02CK
LD02CM
KD22CK
LD22CM
30
10
600
3.5
8.0
Vdc
µAdc
µAdc
ms
ms
RS
CONTROL
Status (sink) Current (VSO < 0.4 Vdc)
Status Turn-On Time (See Fig. 6)
LOAD
RETURN
RETURN
(-) OUTPUT
LOAD
Status Turn-Off Time (See Fig. 6)
(C) 2 TERMINAL INPUT (DIRECT DRIVE) WITH STATUS
S1
VIN
RS IIN
BIAS
22
LOAD
DC
(+) OUTPUT
CONTROL 1
3
RETURN
9
(-) OUTPUT
BIAS (INPUT) CURRENT (mA)
12
VLOAD
KD02CK
LD02CM
KD22CK
LD22CM
KD00CK
LD00CM 1 /
LOAD
18
15
12
9
6
3
0
0
5
LOAD
RETURN
(D) 2 TERMINAL INPUT (DIRECT DRIVE)
RS
BIAS
ICONTROL
VCONTROL
CONTROL
RETURN
(-) OUTPUT
LOAD
A
10 15 20
25
30 40
BIAS (INPUT) VOLTAGE (Vdc)
50
60
VBIAS
IBIAS
LOAD
(+) OUTPUT
KD02CK
LD02CM
KD22CK
LD22CM
KD00CK
LD00CM
VLOAD
BIAS (INPUT) CURRENT VS BIAS (INPUT) VOLTAGE
FIGURE 2 (See Note 1)
1/
LOAD
RETURN
1 / KD02CK, KD22CK, LD02CM and LD22CM may be wired without the status
line as shown in (B), (D) and (E) above.
(E) 3 TERMINAL INPUT WITHOUT STATUS
D
WIRING CONFIGURATIONS
FIGURE 1 (See Note 1)
12/96
©1996 TELEDYNE RELAYS
DC-21
Series KD/LD
DC
100
90
80
PERCENT CURRENT
2.0
NORMALIZED ON RESISTANCE (NR)
1.8
1.6
30A
-55°
25A
1.4
1.2
1.0
0.8
0.6
20A
25°
15A
10A
100°
5A
70
60
50
40
30
20
10
0
-55 -45 -35 -5
5
15 25 35 45 55 65 75 85 95 105 115
AMBIENT TEMPERATURE (°C)
KD20CK
KD22CK
LD20CM
LD22CM
KD00CK
KD02CK
LD00CM
LD02CM
0.4
0.2
0.0
25
50
75
100
JUNCTION TEMPERATURE (C°)
125
10
100
1(s)
1S
10
100
1000'S
BD
LOAD CURRENT DERATING CURVE FOR
KD/LD SERIES WITHOUT A HEAT SINK
(A)
100
90
80
PERCENT CURRENT
NORMALIZED ON RESISTANCE
VS JUNCTION TEMPERATURE
FIGURE 4 (See Note 3)
OVERLOAD CURRENT VS TIME TO TRIP
(TYPICAL)
KD20CK, KD22CK, LD20CM, LD22CM
FIGURE 7
2000
70
60
50
40
30
20
10
0
-55 -45 -35 -5
5
15 25 35 45 55 65 75 85 95 105 115 125
CASE TEMPERATURE (°C)
SERIES RESISTOR (Ohms)
1500
1000
AC
OUTPUT TURN-ON AND TURN-OFF
TIMING
FIGURE 5
500
0
0
5
10
15
20
25
30
35
BIAS VOLTAGE (VOLTS)
LOAD CURRENT DERATING CURVE FOR
LD SERIES
(B)
THERMAL DERATING CURVES
FIGURE 3
STATUS TURN-ON AND TURN-OFF
TIMING
FIGURE 6
SERIES LIMIT BIAS RESISTOR VS BIAS
VOLTAGE
FIGURE 8 (See Note 1)
TURN RELAY ON INTO A SHORTED LOAD
DC
NOTES:
1. Control input is compatible with CMOS or open collector TTL (with pull up resistor).
For bias voltages above 6V, a series resistor is required. Use the standard resistor
value equal to or less than the value found in Figure 8.
2. The rated input voltage is 5V for all tests unless otherwise specified.
3. To calculate the maximum ON resistance for a given junction temperature, find the
normalized ON resistance factor (NR) from Figure 4. Calculate the new ON resistance
as follows:
R(ON) = NR • RON @ 25°C
R(ON) =
(KD00CK, LD00CM, KD02CK, LD02CM)
NR(RON @ +25°C ) + .025 ohm
130ApK
21Apk
250uSEC
A
SHORT-CIRCUIT LOAD WITH RELAY ON
D
(KD20CK, LD20CM, KD22CK, LD22CM)
4. Overload testing to the requirements of MIL-R-28750 is constrained to the limits
imposed by the short circuit protection characteristics as defined in this specification.
System series inductance for “shorted-load” mode of operation should be 50 µH.
Maximum repetition rate into a shorted load should not exceed 10 Hz.
5. A status pull up resistor is required for proper operation of the status output.
Determine the current (Iso) required by the status interface. Calculate the current (Is)
through the status resistor such that the sink current through the status output is 0.6
mA. Select the status resistor such that it does not allow more than 0.6 mA to flow
through the status output.
VSTATUS - 0.4V
RSTATUS =
Iso
6. Inductive loads should be diode suppressed. Input transitions should be
≤
1 ms
duration and the input drive should be a bounceless contact type.
250uSEC
TYPICAL TRIP CURRENT CHARACTERISTICS
FOR SHORT CIRCUIT CONDITIONS
FIGURE 9
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
DC-22