EEWORLDEEWORLDEEWORLD

Part Number

Search

LK4003-6PD6TB2

Description
AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02
CategoryPower/power management    The power supply circuit   
File Size1MB,28 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LK4003-6PD6TB2 Overview

AC-DC Power Factor Correction Module, 1 Output, 150W, HEAT SINK, METAL, CASE K02

LK4003-6PD6TB2 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-XXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature60 °C
Minimum operating temperature-25 °C
Maximum output voltage5.13 V
Minimum output voltage5.07 V
Nominal output voltage5.1 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputNO
Rugged Environment
AC-DC Converters >100 Watt
K Series
150 Watt AC-DC Converters with PFC
Input to output isolation
Single output: LK 4000 5.1, 12, 15, 24 V
Double output: LK 5000 2
×
12, 2
×
15, 2
×
24 V
Universal input voltage range
Power factor
>0.95,
harmonics
<IEC/EN
61000-3-2
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
4 kV
rms
input to output electric strength test
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
C
K-Series
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Summary
The K 4000/5000-series of AC-DC converters represents a
flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified ranges. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected with pin 14 to en-
able the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19 inch rack sys-
tems according to DIN 41494, or be chassis mounted.
Important:
These products are intended to replace the
LK 1000 and LK 2000 in order to comply with IEC/EN
61000-3-2.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 16
Immunity to Environmental Conditions ........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options .................................................... 22
Accessories .................................................................... 28
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 12
MELCHER
The Power Partners.
Edition 4/4.99
1/28
Electronic product software development hardware design product design
I have been engaged in electronic product design for nearly 20 years and have experienced the ups and downs of the industry. As my professional skills have become more and more mature, I always want t...
EVA2016 Mobile and portable
Can you help me write a main function?
I am using 430 launchpad to make a signal generator. The code lacks a main function. I am a novice and don't quite understand it. Please help me! !...
xueshengke Microcontroller MCU
report
Several friends want to add me as a friend, but they spread obscene and pornographic content and advertised. I hope I can deal with it. Thank you! milexiu limeolw voerkor roolrex aimimi2018 These are ...
沽名钓誉 Suggestions & Announcements
Legend has it that I+2+C=I2C
Engineering Application of I2C This project simulates the operation process of EEPROM (CAT24C02) transmission protocol based on the I2C bus of LM3S8962. The system is simple and practical and can be t...
shilaike Embedded System
AM335x-beaglebone development environment Ubuntu10.04 installed to VMware
[b]1. Install Ubuntu 10.04 of AM335x-beaglebone development environment to VMware 1. Install VMware-Tools2. install ti-sdk-am335x-evm 3. run ./setup.sh4. install the Graphics SDK5. Set up USB, first i...
mars4zhu DSP and ARM Processors
I would like to ask how to use directdraw in wince, I want to display the yuv format
As the title says, I just don't understand something. Can you help me with some scientific knowledge? I can't seem to find anything on the Internet....
yangxiao123 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1999  386  1378  1784  636  41  8  28  36  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号