EEWORLDEEWORLDEEWORLD

Part Number

Search

LM1601-9EPV3

Description
AC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, METAL, CASE M02, MODULE
CategoryPower/power management    The power supply circuit   
File Size150KB,4 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LM1601-9EPV3 Overview

AC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, METAL, CASE M02, MODULE

LM1601-9EPV3 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage264 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-XXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage24.144 V
Minimum output voltage23.856 V
Nominal output voltage24 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output50 W
Fine-tuning/adjustable outputNO
M Series
50 Watt AC-DC Converters
Input voltage range 85...264 V AC
1, 2 or 3 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
LGA
• Rugged electrical and mechanical design
• Outputs individually controlled with excellent
dynamic properties
• Operating ambient temperature range
–40...71°C with convection cooling
Selection chart
Output 1
U
o nom
I
o nom
[V DC] [A]
5.1
8
5.1
8
12
4
12
4
15
3.4
15
3.4
24
2
24
2
48
1
48
1
12
2
12
2
15
1.7
15
1.7
5.1
5
5.1
5
5.1
5
5.1
5
Output 2
U
o nom
I
o nom
[V DC] [A]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12
2
12
2
15
1.7
15
1.7
12
0.7
12
0.7
15
0.6
15
0.6
Output 3
U
o nom
I
o nom
[V DC] [A]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12
0.7
12
0.7
15
0.6
15
0.6
Input
voltage
U
i
[V AC]
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
Type
Options
LM 1001-7R
LMZ 1001-7R
LM 1301-7R
LMZ 1301-7R
LM 1501-7R
LMZ 1501-7R
LM 1601-7R
LMZ 1601-7R
LM 1901-7R
LMZ 1901-7R
LM 2320-7
LMZ 2320-7
LM 2540-7
LMZ 2540-7
LM 3020-7
LMZ 3020-7
LM 3040-7
LMZ 3040-7
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
www.power-one.com
1
Looking for digital 2.4G wireless communication?
Does anyone have any information about digital 2.4G wireless communication? Please share, I will be very grateful! ! ! ! !...
NiNoLAM RF/Wirelessly
Are these the reasons why surge testing always burns out amplifier boards?
When doing surge test on the equipment, other parts were not damaged. Why was only the power amplifier board farthest from the power input terminal burned? The equipment layout diagram is as followsBe...
qwqwqw2088 Analogue and Mixed Signal
Memory Type
I recently encountered some problems with memory types, and the following information is summarized:code Program space (64K bytes) MOVC @A+DPTR access data (00H~7FH) Directly access internal data memo...
nicole088 FPGA/CPLD
Do ZLG's USBCAN and Ethernet cards support C++ and C#?
[color=#333333][font=Arial, Helvetica, sans-serif][size=12px]Do ZLG's USBCAN and Ethernet cards support C++ and C#? [/size][/font][/color]...
喜鹊王子 TI Technology Forum
Master-slave station program when two PLCs are connected using an N:N network
I would like to ask the master and slave station program when connecting two PLCs in N:N mode. The program written according to the tutorial has problems, and the two PLCs cannot communicate normally....
总是说太多 Integrated technical exchanges
Brief introduction to hearing aid instructions and usage recommendations
Brief introduction to hearing aid instructions and usage recommendations   The application of electronic technology in the medical field has brought revolutionary development to medical technology. As...
sairvee Medical Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1703  1469  2482  2762  1789  35  30  50  56  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号