PB08Q-701BB

Description
Mains Power Connector, 8A, 115/250VAC, Male, Socket
CategoryThe connector    The connector   
File Size345KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

PB08Q-701BB Overview

Mains Power Connector, 8A, 115/250VAC, Male, Socket

PB08Q-701BB Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARD: IEC 60320
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings8A, 115/250VAC
Manufacturer's serial numberPB
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
PB Series
STRAIGHT, SNAP-IN/FLANGE MOUNT FILTER WITH IEC 60320
AC INLET SOCKET.
MECHANICAL DIMENSIONS
(Unit: mm)
FLANGE MOUNT
50.1
30.3
22.5
40.0
28.5
4-R5
21.6
2-
3.3
40.0
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
45.5
46.8
41.4
55.8
G
28.3
20.6
SNAP-IN (SNT)
FEATURES
31.0
The PB series, similar to PA and PASP series, offers filters with
IEC connector providing effective equipment protection of
line-to-ground noise up to 15 Amp, 250VAC. The compact
design filter with low leakage current is well suited for
applications that require strict national and international
emission standards. These filters are also available for
Medical application and offer extremely low Leakage current
to comply with UL544, UL2601 and CSA22.2 standards.
A ground choke can be added to enhance the grounding
ability of the circuit. Bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
55.2
43.6
24.0
21.9
21.2
4-R2
28.5
4-R2
29.6
SUGGESTED PANEL CUTOUT** SUGGESTED PANEL CUTOUT**
(MOUNTING FROM FRONT)
(MOUNTING FROM FRONT)
SNT Option
SSI Option
3.75
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
28.3
20.6
FLANGE MOUNT (B)
52
40
40.0
28.5
4-R5
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 6A, 8A, 10A, 15A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application; ** Thickness of Panel is from 1.00mm to 1.6mm
25
2-
3.3
3.5
21.6
30.3
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
45.5
46.8
41.4
55.8
G
28.3
20.6
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
8
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
Several 2812 data manuals worth referring to
The first one is C281x C/C++ header files and peripheral examples, which contains TI standard CMD files. The query number is SPRC097. It mainly introduces the definition of header files and some routi...
sobi Microcontroller MCU
TED Talk: The Amazing Potential of Sixth Sense Technology
It's quite old, you may have seen it, if you haven't you can take a look, although I doubt its practicality, but the technology it demonstrates should be quite impressive [flash]http://player.youku.co...
wangfuchong Talking
M4 receives FPGA data via serial port
I am a newbie and I just started to learn M4. I want a program to use M4 to receive FPGA data and use JLX12864G LCD to display it....
季末以後 Microcontroller MCU
[Help] Why can't I write a program into your company's 449 experimental board?
I can't write the program into your company's 449 experimental board. After dubegger, it always shows Una××e to connect to lptx.I changed to the new version (3.41a) and it shows:FATAL ERRORUnknown exc...
aazz Microcontroller MCU
How to scan keys on this triangular keyboard
[color=#333333][font=Arial]The bottom row is connected to GND, and the others are connected to IO. When scanning the keys, set the first row to 0, scan the first column, set the second row to 0, scan ...
holikey MCU
Want to buy stm32f103cXX chip
I am making a prototype now and need a few STM32 chips. Do you have any spare chips?Still needWant to buy 3 stm32f103cXX chips, 3 mc33290 chipsContact QQ 289916015...
05210324kw Buy&Sell

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 68  2055  1469  949  1149  2  42  30  20  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号