All products are sold to the commercial specifications shown for any additional reliability testing or extended parameters, please consult the factory.
8
contact semitron on: telephone:
+44 (0)1793 724000
fax:
+44 (0)1793 720401
ELECTRICAL SPECIFICATION @ Tamb = 25°C
PART
NUMBER
UNI-POLAR
DEVICE
CODE
REVERSE
STANDOFF
VOLTAGE
V
R
(Volts)
MIN
P6SMBJ 6V8 / P6SMBJ 6V8C
P6SMBJ 6V8A / P6SMBJ 6V8CA
P6SMBJ 7V5 / P6SMBJ 7V5C
P6SMBJ 7V5A / P6SMBJ 7V5CA
P6SMBJ 8V2 / P6SMBJ 8V2C
P6SMBJ 8V2A / P6SMBJ 8V2CA
P6SMBJ 9V1 / P6SMBJ 9V1C
P6SMBJ 9V1A / P6SMBJ 9V1CA
P6SMBJ 10 / P6SMBJ 10C
P6SMBJ 10A / P6SMBJ 10CA
P6SMBJ 11 / P6SMBJ 11C
P6SMBJ 11A / P6SMBJ 11CA
P6SMBJ 12 / P6SMBJ 12C
P6SMBJ 12A / P6SMBJ 12CA
P6SMBJ 13 / P6SMBJ 13C
P6SMBJ 13A / P6SMBJ 13CA
P6SMBJ 15 / P6SMBJ 15C
P6SMBJ 15A / P6SMBJ 15CA
P6SMBJ 16 / P6SMBJ 16C
P6SMBJ 16A / P6SMBJ 16CA
P6SMBJ 18 / P6SMBJ 18C
P6SMBJ 18A / P6SMBJ 18CA
P6SMBJ 20 / P6SMBJ 20C
P6SMBJ 20A / P6SMBJ 20CA
P6SMBJ 22 / P6SMBJ 22C
P6SMBJ 22A / P6SMBJ 22CA
P6SMBJ 24 / P6SMBJ 24C
P6SMBJ 24A / P6SMBJ 24CA
P6SMBJ 27 / P6SMBJ 27C
P6SMBJ 27A / P6SMBJ 27CA
P6SMBJ 30 / P6SMBJ 30C
P6SMBJ 30A / P6SMBJ 30CA
P6SMBJ 33 / P6SMBJ 33C
P6SMBJ 33A / P6SMBJ 33CA
P6SMBJ 36 / P6SMBJ 36C
P6SMBJ 36A / P6SMBJ 36CA
P6SMBJ 39 / P6SMBJ 39C
P6SMBJ 39A / P6SMBJ 39CA
P6SMBJ 43 / P6SMBJ 43C
P6SMBJ 43A / P6SMBJ 43CA
P6SMBJ 47 / P6SMBJ 47C
P6SMBJ 47A / P6SMBJ 47CA
P6SMBJ 51 / P6SMBJ 51C
P6SMBJ 51A / P6SMBJ 51CA
Notes:
1. Testing is performed @ 25˚
2. Bv is measured using a pulse of 20 milliseconds or less
3. V
F
, for uni-diectional devices, is measured using a 300 microsecond square wave pulse @
I
T
= 50A
4.
I
R
is doubled for Bi-directional devices only with V
R
equal or less than 10 volts
6V8 / 6V8C
6V8A /6V8CA
7V5 / 7V5C
7V5A / 7V5CA
8V2 / 8V2C
8V2A / 8V2CA
9V1 / 9V1C
9V1A / 9V1CA
10 / 10C
10A / 10CA
11 / 11C
11A / 11CA
12 / 12C
12A / 12CA
13 / 13C
13A / 13CA
15 / 15C
15A / 15CA
16 / 16C
16A / 16CA
18 / 18C
18A / 18CA
20 / 20C
20A / 20CA
22 / 22C
22A / 22CA
24 / 24C
24A / 24CA
27 / 27C
27A / 27CA
30 / 30C
30A / 30CA
30 / 33C
33A / 33CA
36 / 36C
36A / 36CA
39 / 39C
39A / 39CA
43 / 43C
43A / 43CA
47 / 47C
47A / 47CA
51 / 51C
51A / 51CA
5.50
5.80
6.05
6.40
6.63
7.02
7.37
7.78
8.10
8.55
8.92
9.40
9.72
10.2
10.5
11.1
12.1
12.8
12.9
13.6
14.5
15.3
16.2
17.1
17.8
18.8
19.4
20.5
21.8
23.1
24.3
25.6
26.8
28.2
29.1
30.8
31.6
33.3
34.8
36.8
38.1
40.2
41.3
43.6
6.12
6.45
6.75
7.13
7.38
7.79
8.19
8.65
9.00
9.50
9.90
10.50
10.80
11.40
11.70
12.40
13.50
14.30
14.40
15.20
16.20
17.10
18.00
19.00
19.80
20.90
21.60
22.80
24.30
25.70
27.00
28.50
29.70
31.40
32.40
34.20
35.10
37.10
38.70
40.90
42.30
44.70
45.90
48.50
BREAKDOWN
VOLTAGE
V
BR
(Volts) @
I
T
MAX
7.48
7.14
8.25
7.88
9.02
8.61
10.00
9.55
11.00
10.50
12.10
11.60
13.20
12.60
14.30
13.70
16.50
15.80
17.60
16.80
19.80
18.90
22.00
21.00
24.20
23.10
26.40
25.20
29.70
28.40
33.0
31.50
36.30
34.70
39.60
37.80
42.90
41.00
47.30
45.20
51.70
49.40
56.10
53.60
10.0
10.0
10.0
10.0
10.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1000.0 (4)
1000.0 (4)
500.0 (4)
500.0 (4)
200.0 (4)
200.0 (4)
50.0 (4)
50.0 (4)
10.0 (4)
10.0 (4)
5.0 (4)
5.0 (4)
5.0 (4)
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
MAXIMUM
REVERSE
LEAKAGE
I
R
@ V
R
(µA)
MAXIMUM
CLAMPING
VOLTAGE
V
C
@
I
PP
(Volts)
(mA)
10.8
10.5
11.7
11.3
12.5
12.1
13.8
13.4
15.0
14.5
16.2
15.6
17.3
16.7
19.0
18.2
22.0
21.2
23.5
22.5
26.1
25.2
29.1
27.7
31.9
30.6
34.7
33.2
39.1
37.5
43.5
41.4
47.7
45.7
52.0
49.9
56.4
53.9
61.9
59.3
67.8
64.8
73.5
70.1
MAXIMUM MAXIMUM
PEAK PULSE FORWARD
CURRENT
VOLTAGE
I
PP
@ V
C
(V
F
) @
I
T
(A)
(Volts)
56.0
57.0
51.0
53.0
48.0
50.0
44.0
45.0
40.0
41.0
37.0
38.0
35.0
36.0
32.0
33.0
27.0
28.0
26.0
27.0
23.0
24.0
21.0
22.0
19.0
20.0
17.0
18.0
15.0
16.0
14.0
14.4
12.6
13.2
11.6
12.0
10.5
11.2
9.6
10.1
8.9
9.3
8.2
8.6
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
All products are sold to the commercial specifications shown, for any additional reliability testing or extended parameters, please consult the factory.
contact semitron on: telephone:
+44 (0)1793 724000
fax:
+44 (0)1793 720401
9
ELECTRICAL SPECIFICATION @ Tamb = 25°C
PART
NUMBER
UNI-POLAR
DEVICE
CODE
REVERSE
STANDOFF
VOLTAGE
V
R
(Volts)
MIN
P6SMBJ 56 / P6SMBJ 56C
P6SMBJ 56A / P6SMBJ 56CA
P6SMBJ 62 / P6SMBJ 62C
P6SMBJ 62A / P6SMBJ 62CA
P6SMBJ 68 / P6SMBJ 68C
P6SMBJ 68A / P6SMBJ 68CA
P6SMBJ 75/ P6SMBJ 75C
P6SMBJ 75A / P6SMBJ 75CA
P6SMBJ 82 / P6SMBJ 82C
P6SMBJ 82A / P6SMBJ 82CA
P6SMBJ 91 / P6SMBJ 91C
P6SMBJ 91A / P6SMBJ 91CA
P6SMBJ 100 / P6SMBJ 100C
P6SMBJ 100A / P6SMBJ 100CA
P6SMBJ 110 / P6SMBJ 110C
P6SMBJ 110A / P6SMBJ 110CA
P6SMBJ 120 / P6SMBJ 120C
P6SMBJ 120A / P6SMBJ 120CA
P6SMBJ 130 / P6SMBJ 130C
P6SMBJ 130A / P6SMBJ 130CA
P6SMBJ 150 / P6SMBJ 150C
P6SMBJ 150A / P6SMBJ 150CA
P6SMBJ 160 / P6SMBJ 160C
P6SMBJ 160A / P6SMBJ 160CA
P6SMBJ 170 / P6SMBJ 170C
P6SMBJ 170A / P6SMBJ 170CA
P6SMBJ 180 / P6SMBJ 180C
P6SMBJ 180A / P6SMBJ 180CA
P6SMBJ 200 / P6SMBJ 200C
P6SMBJ 200A / P6SMBJ 200CA
P6SMBJ 220 / P6SMBJ 220C
P6SMBJ 220A / P6SMBJ 220CA
Notes:
1. Testing is performed @ 25˚
2. Bv is measured using a pulse of 20 milliseconds or less
3. V
F
, for uni-diectional devices, is measured using a 300 microsecond square wave pulse @
I
T
= 50A
4.
I
R
is doubled for Bi-directional devices only with V
R
equal or less than 10 volts
56 / 56C
56A / 56CA
62 / 62C
62A / 62CA
68 / 68C
68A / 68CA
75 / 75C
75A / 75CA
82 / 82C
82A / 82CA
91 / 91C
91A / 91CA
100 / 100C
100A / 100CA
110 / 110C
110A / 110CA
120 / 120C
120A / 120CA
130 / 130C
130A / 130CA
150 / 150C
150A / 150CA
160 / 160C
160A / 160CA
170 / 170C
170A / 170CA
180 / 180C
180A / 180CA
200 / 200C
200A / 200CA
220 / 220C
220A / 220CA
45.4
47.8
50.2
53.0
55.1
58.1
60.7
64.1
66.4
70.1
73.7
77.8
81.0
85.5
89.2
94.0
97.2
102.0
105.0
111.0
121.0
128.0
130.0
136.0
138.0
145.0
146.0
154.0
162.0
171.0
175.0
185.0
50.40
53.20
55.80
58.90
61.20
64.60
67.50
71.30
73.80
77.90
81.90
86.50
90.00
95.00
99.00
105.00
108.00
114.00
117.00
124.00
135.00
143.00
144.00
152.00
153.00
162.00
162.00
171.00
180.00
190.00
198.00
209.00
BREAKDOWN
VOLTAGE
V
BR
(Volts) @
I
T
MAX
61.60
58.80
68.20
65.10
74.80
71.40
82.50
78.80
90.20
86.10
100.00
95.50
110.00
105.00
121.00
116.00
132.00
126.00
143.00
137.00
165.00
158.00
176.00
168.00
187.00
179.00
198.00
189.00
220.00
210.00
242.00
231.00
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
MAXIMUM
REVERSE
LEAKAGE
I
R
@ V
R
(µA)
MAXIMUM
CLAMPING
VOLTAGE
V
C
@
I
PP
(Volts)
(mA)
80.5
77.0
89.0
85.0
98.0
92.0
108.0
103.0
118.0
113.0
131.0
125.0
144.0
137.0
158.0
152.0
173.0
165.0
187.0
179.0
215.0
207.0
230.0
219.0
244.0
234.0
258.0
246.0
287.0
274.0
344.0
328.0
MAXIMUM MAXIMUM
PEAK PULSE FORWARD
CURRENT
VOLTAGE
I
PP
@ V
C
(V
F
) @
I
T
(A)
(Volts)
7.4
7.8
6.8
7.1
6.1
6.5
5.5
5.8
5.1
5.3
4.5
4.8
4.2
4.4
3.8
4.0
3.5
3.6
3.2
3.3
2.8
2.9
2.6
2.7
2.5
2.6
2.3
2.4
2.1
2.2
1.8
1.8
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
All products are sold to the commercial specifications shown for any additional reliability testing or extended parameters, please consult the factory.
Modbus Protocol Summary: Industrial control has evolved from single-machine control to centralized monitoring and distributed control. Now it has entered the network era. The networking of industrial ...
[i=s]This post was last edited by lonerzf on 2014-8-3 18:16[/i] [size=3]A friend on the forum encountered some difficulties. The reason is very simple. I didn't explain something clearly before. Altho...
[i=s]This post was last edited by nemo1991 on 2015-3-16 17:01[/i] [align=left]The controlSUITE component package created by TI for the C2000 series DSP contains a wealth of technical resources. For in...
JTAG is a parallel port of a computer. JTAG is also an international standard test protocol (IEEE 1149.1 compatible), mainly used for internal chip testing. Most advanced devices now support the JTAG ...
Today's computer peripherals are pursuing high speed and high versatility. In order to meet user needs, seven companies led by Intel launched the USB (Universal Serial Bus) bus protocol in 1994, wh...[Details]
Hardware designers have begun to adopt FPGA technology in high-performance DSP designs because it can provide 10-100 times faster computing than PC-based or microcontroller-based solutions. Previou...[Details]
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
In
circuit design,
current
measurement
is widely used, and the main fields are divided into three categories: in measurement,
the electric meter
is used to measure the curre...[Details]
When the WDP500-2A plane grating monochromator is used to test the emission wavelength of a high-power laser diode at different currents, the matching of the laser diode has the disadvantages of lo...[Details]
The solidification and modularization of intelligent video analysis algorithms are the current trends in the application of intelligent video analysis technology. It perfectly combines intelligent ...[Details]
0 Introduction
With the rise and continuous improvement of the solid-state lighting industry, light-emitting diodes (LEDs) have become an alternative lighting technology and are gr...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
This article will introduce a design method for a distributed control system used in a tracking car, which can perform distributed control of motor modules, sensor modules, and lighting control mod...[Details]
a. Keep the battery clean, wipe off the spilled electrolyte, contaminated dirt and dust in time; keep the poles and terminal clamps clean and in good contact, and apply vaseline or butter to preven...[Details]
The most important components of new energy electric vehicles are power batteries, electric motors and energy conversion control systems. The power battery must achieve high performance such as fas...[Details]
HL201A is a special thick film driver integrated circuit with a capacity of less than 75AGTR developed by Xi'an Power Electronics Technology Research Institute. The article explains the pin arrange...[Details]
Energy conservation and environmental protection are the main directions of current automotive technology research, and power batteries are the key to electric vehicle technology. Research on powe...[Details]
Synchronous buck designs are becoming increasingly difficult, and the selection of suitable ICs is becoming quite narrow. This Design Idea combines a current-mode PWM IC used in a flyback regulator...[Details]
Some people believe that hybrid vehicles are just a transitional product, and the ultimate goal of developing new energy vehicles is electric vehicles. Therefore, China should skip hybrid vehicles ...[Details]