EEWORLDEEWORLDEEWORLD

Part Number

Search

2026-25C2LF

Description
Surge Protection Circuit, ROHS COMPLIANT PACKAGE
CategoryWireless rf/communication    Telecom circuit   
File Size536KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2026-25C2LF Overview

Surge Protection Circuit, ROHS COMPLIANT PACKAGE

2026-25C2LF Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Parts packaging codeMODULE
package instruction,
Contacts3
Reach Compliance Codecompli
JESD-30 codeO-XXSS-P3
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Number of terminals3
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeROUND
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal surfaceTin (Sn)
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
V E S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced TRIGARD
®
Approximately 8 mm diameter, 11 mm long
UL recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Model No.
2026-20
200 V
425 V
625 V
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2026-07
75 V
275 V
700 V
2026-09
90 V
275 V
600 V
2026-15
150 V
350 V
575 V
2026-23
230 V
450 V
650 V
2026-25
250 V
475 V
700 V
2026-26
260V
1
475 V
700 V
2026-30
300 V
500 V
775 V
2026-35
350 V
625 V
875 V
Model No.
2026-40
2026-42
400 V
420 V
675 V
925 V
725 V
1000 V
2026-47
470 V
800 V
1100 V
2026-60
600 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/µs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
2
.................................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20 µs
3
.................................................... 1 operation minimum
20000 A, 8/20 µs ...................................................... > 10 operations
5000 A, 10/350 µs ................................................... 1 operation
1000 A, 10/1000 µs ................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
3
............................................... 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Optional Switch-Grade Fail-short device available.
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >10
8
Ω
(-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
1
2
3
Tube meets BT requirement Type 14 A/1 (210-310 V).
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Friends who are familiar with power amplifiers can look at this picture.
Can you explain this picture? I don't quite understand the function of the circled tube... I've asked many people but none of them could explain it perfectly....
595818431 Analog electronics
【MM32 eMiniBoard Review】+ Development Environment Construction and Download Test
Download MM32F013x_Lib_Samples_V1.02 from the official website http://www.mm32mcu.com/ to get the corresponding routines; download MindMotion.MM32F0130_DFP.1.0.1.pack to provide chip support, use MM32...
jinglixixi Domestic Chip Exchange
Research on the Design of Low Noise Amplifier Circuit for CDMA RF Front End
This paper summarizes several problems in the design of RF front-end low noise amplifier circuits and discusses the . Based on the relevant processing and the design requirements of RF low noise ampli...
JasonYoo RF/Wirelessly
The development direction of embedded talents, giving guidance to students engaged in embedded development (transferred)
[color=#FF0000][b][size=11px]Embedded systems[/size][/b][/color] are undoubtedly one of the hottest and most promising IT application fields. Embedded systems are used on some specific special equipme...
gonnago1 Embedded System
How to connect the telephone line?
How do I connect a two-core phone line? What is the line sequence? How do I connect a four-core phone line? What is the line sequence? What are the phone line ends? It would be best if there are pictu...
mjj19680827 Embedded System
After installing the network card driver, why is there no network connection?
I used the DDK example for the network card driver, isdnwan. After compiling it, I installed it. I can see that the driver and network card are installed, but why is it not in the network connection? ...
freeaqi Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1022  156  103  1596  126  21  4  3  33  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号