LPV-100 Overview

100W Single Output Switching Power Supply

100W Single Output Switching Power Supply
Features :
L P V- 1 0 0
series
Constant voltage design
Universal AC input / Full range
Fully encapsulated with IP67 level (Note.8)
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Fully isolated plastic case
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)(Note 7.)
IS 15885(Part 2/Sec13)
2 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LPV-100-5
5V
12A
0 ~ 12A
60W
LPV-100-12
12V
8.5A
0 ~ 8.5A
102W
120mVp-p
±5.0%
±2.0%
2000ms, 25ms / 115VAC
14ms/115VAC at full load
127 ~ 370VDC
85%
87%
88%
LPV-100-15
15V
6.7A
0 ~ 6.7A
100.5W
120mVp-p
24V
4.2A
0 ~ 4.2A
100.8W
IP67
THOMAS SAMUEL
THOMAS SAMUEL
(for 12V,24V only)
R-41027766
LPV-100-24
LPV-100-36
36V
2.8A
0 ~ 2.8A
100.8W
150mVp-p
LPV-100-48
48V
2.1A
0 ~ 2.1A
100.8W
150mVp-p
RIPPLE & NOISE (max.)
Note.2
80mVp-p
VOLTAGE TOLERANCE
Note.3
±8.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
LEAKAGE CURRENT
OVERLOAD
±1.0%
±6.0%
50ms/230VAC
Note.4
90 ~ 264VAC
150mVp-p
Note.6
2000ms, 25ms / 230VAC
47 ~ 63Hz
80%
88%
89%
2.2A/115VAC 1.2A/230VAC
COLD START 75A(twidth=700
μ
s measured at 50% Ipeak) at 230VAC
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
0.25mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
-25 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL8750,CSA C22.2 No 250.13-12
,
UL879,CSA C22.2 No.207-M89,BIS IS15885(for LPV-100-12,LPV-100-24 only),
EAC TP TC 004,IP67 approved. Design refer to EN60950-1
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A(
80% load), EN61000-3-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A, EAC TP TC 020
703Khrs min.
MIL-HDBK-217F (25
)
190*52*37mm (L*W*H)
0.63Kg;20pcs/13.6Kg/0.55CUFT
INPUT
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
41.4 ~ 48.6V
55.2 ~ 64.8V
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure.
9. The ambient temperature derating of 3.5
/1000m with fanless models and of 5
/1000m with fan models for operating altitude higher than 2000m(6500ft).
10. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
‘
File Name:LPV-100-SPEC 2018-09-30

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1183  2835  2267  395  2462  24  58  46  8  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号