Part Number

Search

2026-20A1LF

Description
Surge Protection Circuit, ROHS COMPLIANT PACKAGE
CategoryWireless rf/communication    Telecom circuit   
File Size536KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric View All

2026-20A1LF Overview

Surge Protection Circuit, ROHS COMPLIANT PACKAGE

2026-20A1LF Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Parts packaging codeMODULE
package instruction,
Contacts3
Reach Compliance Codecompli
JESD-30 codeO-XXSS-P3
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Number of terminals3
Maximum operating temperature90 °C
Minimum operating temperature-40 °C
Package body materialUNSPECIFIED
Package shapeROUND
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelINDUSTRIAL
Terminal surfaceTin (Sn)
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
V E S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced TRIGARD
®
Approximately 8 mm diameter, 11 mm long
UL recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Model No.
2026-20
200 V
425 V
625 V
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2026-07
75 V
275 V
700 V
2026-09
90 V
275 V
600 V
2026-15
150 V
350 V
575 V
2026-23
230 V
450 V
650 V
2026-25
250 V
475 V
700 V
2026-26
260V
1
475 V
700 V
2026-30
300 V
500 V
775 V
2026-35
350 V
625 V
875 V
Model No.
2026-40
2026-42
400 V
420 V
675 V
925 V
725 V
1000 V
2026-47
470 V
800 V
1100 V
2026-60
600 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/µs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
2
.................................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20 µs
3
.................................................... 1 operation minimum
20000 A, 8/20 µs ...................................................... > 10 operations
5000 A, 10/350 µs ................................................... 1 operation
1000 A, 10/1000 µs ................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
3
............................................... 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Optional Switch-Grade Fail-short device available.
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >10
8
Ω
(-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
1
2
3
Tube meets BT requirement Type 14 A/1 (210-310 V).
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Problem with launching hibernation mode!
I am working on a project. After pressing a button for 5 seconds, I give LEDOnOff a value of SWITCHOFF, which is a defined enumeration type. Then I execute the following program to enter sleep mode, b...
零晨 Microcontroller MCU
Ask: PCI card DMA transmission problem under Windows
I recently used Tiger320 chip to write a communication driver for PCI card under Windows, and used Tiger320 DMA transmission. Now I have encountered some problems. I hope you can give me some advice: ...
zxjk001 Embedded System
Based on fpga controllable divider.doc
Based on fpga controllable divider.doc...
zxopenljx FPGA/CPLD
WINCE WIFI
Dear experts, I have a CE CF interface WIFI wireless network card, but there is no 5.0 driver, only 3.0 driver. Can I modify it and use it?...
springrain8888 Embedded System
2G---5G and future antenna technology
Source: Filter Author: Junmao Over the past two decades, we have witnessed the transformation of mobile communications from 1G to 4G LTE. During this period, key communication technologies have change...
btty038 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1761  2398  1662  279  2525  36  49  34  6  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号