RF RELAY, DPST, MOMENTARY, 0.025A (COIL), 15VDC (COIL), 375mW (COIL), 3000MHz, 1W (RF INPUT), THROUGH HOLE-STRAIGHT MOUNT
CategoryMechanical and electronic products    relay   
File Size141KB,8 Pages
ManufacturerTeledyne Technologies Incorporated
Websitehttp://www.teledyne.com/
Download Datasheet Parametric View All

A150-815/SQ Overview

RF RELAY, DPST, MOMENTARY, 0.025A (COIL), 15VDC (COIL), 375mW (COIL), 3000MHz, 1W (RF INPUT), THROUGH HOLE-STRAIGHT MOUNT

A150-815/SQ Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Other featuresLOW LEVEL CONTACT LIFE 10000000
body width9.53 mm
body height7.11 mm
Body length or diameter12.07 mm
Characteristic impedance50 Ω
Maximum coil current (DC)0.025 A
Coil operating voltage (DC)11.3 V
Coil power375 mW
Coil resistance610 Ω
Maximum coil voltage (DC)15 V
Coil/Input Power TypeDC
Contact/Output Power TypeDC
Maximum input power1 W
Maximum insertion loss0.3 dB
JESD-609 codee0
Manufacturer's serial numberA150
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours4 ms
Maximum operating frequency3000 MHz
Minimum operating frequency
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
physical size12.07mm X 9.53mm X 7.11mm
Relay actionMOMENTARY
Relay functionDPST
Relay typeRF RELAY
sealHERMETICALLY SEALED
surface mountNO
switching time4 ms
Terminal surfaceTIN LEAD
Termination typeSOLDER
voltage standing wave ratio1.25
Base Number Matches1
RF & MICROWAVE
SERIES
ULTRAMINIATURE
BROADBAND
ATTENUATOR RELAYS
A150
SERIES
DESIGNATION
A150
Attenuator Relay series
RELAY TYPE
INTERNAL CONSTRUCTION
DESCRIPTION
The Series A150 ultraminiature Attenuator Relays are designed for
attenuating RF signals in 50-ohm systems over a frequency range from DC
to 3 GHz. Their low profile and small grid spacing makes them ideal for use
when packaging density is a prime consideration. The A150 relays eliminate
the need for additional external resistors.
These single section, switchable attenuator relays have internal matched thin
film attenuator pads in “L,” “T” or “Pi” configurations, as applicable. Relays are
Stationary Contact
Moving Contact
Attenuator Pad/
Contact Assembly
Armature
SCHEMATIC DIAGRAM
available in fixed increments of 1, 2, 3, 4, 5, 6, 8, 10, 16 and 20 dB, which
3
2
1
Terminal view. Case ground.
5
6
7
can used singly or in combination to achieve the attenuation levels desired.
The A150 attenuator relay features:
• Unique uni-frame motor design which provides high magnetic efficiency
and mechanical rigidity.
• Minimum mass components and welded construction for maximum
resistance to shock and vibration.
• Advanced cleaning techniques which assures internal cleanliness.
• Gold plated, precious metal contacts, which provide excellent
intermodulation performance.
• Flat amplitude vs. frequency response.
• High isolation between control and signal path.
• Stable attenuation vs. temperature.
• Excellent phase linearity.
• Highly resistant to ESD.
Patent No. 5,315,273
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
–65°C to +125°C
Temperature Storage
(Ambient)
Operating
–55°C to +85°C
Vibration
(General Note 1)
Shock
(General Note 1)
Enclosure
Weight
A150 Page
1
10 g’s to 500 Hz
30 g’s,
6 msec, half-sine
Hermetically sealed
0.11 oz. (3.12g) max.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2003 TELEDYNE RELAYS
A150/1203/Q1
Learn how to get started with embedded systems.
Personally, I think it depends on personal interest, whether you want to develop in the software direction or the hardware direction. If you want to develop in the software direction, I suggest you fi...
6294316 Embedded System
Introduction to the cooperative research and development project of new household heat meters 2007-10-19
Introduction to the cooperative research and development project of new household heat meters 2007-10-19 Researcher: Zhao Heping 1. Domestic and foreign situation Most of the heat meters currently use...
zhaoheping Industrial Control Electronics
Are Baogong’s products easy to use?
[i=s]This post was last edited by minjiang on 2014-7-22 20:08[/i] Nowadays, there are more and more people who like to talk, and fewer people who work. Recently, the Ministry of Education seems to be ...
minjiang Microcontroller MCU
[AT-START-F403A Evaluation] Part 1 FreeRTOS System IAR Environment Construction
I had some knowledge of Arteli's products through a friend's recommendation a year ago. My current project is coming to an end, and I have started many evaluations for the new project. The evaluation ...
uuxz99 Domestic Chip Exchange
Wince eboot flash management problem
I use S3C2410 chip and K9F1208 FLASH. Now my EBOOT can download NK.BIN directly and start in RAM, but cannot start in FLASH. HyperTerminal displays as follows: TFTP: Desktop losing ACK, block number =...
ldrxxx Embedded System
Has anyone developed a complete electronics product?
Has anyone developed a complete electronic product? Did you make the shell yourself? Or was it custom made? Please explain the market situation and do you have any recommended manufacturers?...
wugx Mobile and portable

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1218  2565  382  1789  1225  25  52  8  37  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号