Reference level for the relative attenuation arel of the TFS280H is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the -3 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 280 MHz without tolerance. The given values for the relative
attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Insertion Loss
Nominal Frequency
Centre Frequency
Relative Attenuation
f
N
f
N
f
N
f
N
f
N
...
±
±
±
18,7
19,2
20,0
f
N
MHz ... f
N
MHz ... f
N
MHz ... f
N
... f
N
±
±
±
±
9,5
19,2
20,0
100,0
MHz
MHz
MHz
MHz
ae
f
N
f
C
arel
typ. value
7,6
279,9
280
MHz
MHz
MHz
tolerance / limit
max.
10
280
-
dB
MHz
0,8
35
30
43
dB
dB
dB
dB
max.
min.
min.
min.
3
16
25
40
dB
dB
dB
dB
Group Delay Ripple
±
8,1
MHz
OTR
TCf
**
25
-
-
- 87
-
ppm/K
max.
ns
30
- 40°C ... + 85°C
- 40°C ... + 85°C
-
10
dBm
ns
Operating Temperature Range
Storage Temperature Range
Temperature Coefficient of Frequency
Input Power Level
*)
The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**)
∆f(Hz)
= TCf(ppm/K) x (T-T
0
) x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 280h.doc
Version 1.5
03.03.2006
VI
TELEFILTER
Filter characteristic
0
Filter specification
TFS 280H
2/5
0
0.586
-7
-1
0.562
-14
-2
0.538
-21
-3
0.514
magnitude in dB
magnitude in dB
-28
-4
0.49
-35
-5
0.466
-42
-6
0.442
-49
-7
0.418
-56
-8
0.394
-63
-9
0.37
-70
220.7857
232.8286
244.8714
256.9143
268.9571
281
293.0429
frequency in MHz
305.0857
317.1286
329.1714
341.2143
-10
267
269.8
272.6
275.4
278.2
281
283.8
frequency in MHz
286.6
289.4
292.2
0.346
295
Construction and pin connection
(All dimensions in mm)
7
5
280H
●
U09
1
3
Date code
1
2
3
4
5
6
7
8
Ground
Input RF Return
Input
Ground
Ground
Output RF Return
Output
Ground
1
3
5
- 0,10
+
0,15
0,64
1,8 Max.
Date code:
U
V
W
...
1,1
2,54
50 Ohm Test circuit
L1
0,1
7
5
1,1
Year + week
2006
2007
2008
120°
3
2
7
L2
SAW
6
C2
C1
1, 4, 5, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
delay in µs
Filename: tfs 280h.doc
Version 1.5
03.03.2006
VI
TELEFILTER
Stability characteristics
1.
2.
3.
4.
5.
6.
7.
8.
9.
High Temperature (IEC 60068 -3-1)
1,000 hours at +85C
Low Temperature (IEC 60068 -3-1)
1,000 hours at – 40C
Humidity (IEC 60068 -2-78)
1,000 hours at 85% /85C
Thermal Shock ( IEC60068-2-14 )
-55 °C to 125°C / 30 min. each / 10 cycles
Filter specification
TFS 280H
3/5
Vibration (IEC 60068 -2-6)
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans
Shock (IEC 60068 -2-27)
500g, 1 ms, half sine wave, 3 shocks each plane
Reflow Profile ( defined at specification )
260°C +/- 5°C for 10 seconds, 2 cycles
Solerability
235°C +/- 5°C for 15 seconds, 1 cycle
Pullability, Distortion
according to MIL-STD 883 method 2004.5 Condition D
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,30 ± 0,1
Bo
: 5,30 ± 0,1
Ct
: 9,5 ± 0,1
Pull Off Direction
P1
3000
min. 300 mm
min. 500 mm
min. 300 mm
t
Do
PIN Marker
Po
P2
E
G
Ct
Bo
F
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
G
W
Filename: tfs 280h.doc
Version 1.5
03.03.2006
VI
TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 280H
4/5
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
30 ... 150 s
Time / s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 280h.doc
Version 1.5
03.03.2006
VI
TELEFILTER
History
Version
1.0
1.1
1.2
Reason of Changes
generate specification
Filter specification
TFS 280H
5/5
Name
Pfeiffer
Chilla
Dr. Wall
Date
17.03.2003
02.06.2003
19.06.2003
frequency range for group delay ripple (GDR) changed
pin 6 set to output rf return
Reel information corrected.
Preliminary values for termination impedances added.
50
Ω
matching network added.
Relative attenuation of 16 dB and 25 dB added.
insertion loss changed.
temperature coefficient of frequency added.
50
Ω
matching network modified.
termination impedance changed
typical values added.
filter characteristics added
test circuit updated
stability characteristics updated
air reflow temperature conditions updated
1.3
Chilla
14.08.2003
1.4
1.5
Chilla
Chilla
13.01.2004
03.03.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.