EEWORLDEEWORLDEEWORLD

Part Number

Search

SFSD-10-30C-S-03.25-DL-NUX

Description
Interconnection Device
CategoryThe connector    The connector   
File Size627KB,4 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

SFSD-10-30C-S-03.25-DL-NUX Overview

Interconnection Device

SFSD-10-30C-S-03.25-DL-NUX Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
REVISION L
(No OF POS x .050[1.27])
+ .015[0.38] REF
N-1 (SEE TABLE 2)
C
L
TEFLON CABLE OPTION
**
-T: TEFLON
(LEAVE BLANK FOR STANDARD PVC INSULATION)
SFSDX-XX-XXX-XX-XX.XX-XX-XXX
01
DO NOT
SCALE FROM
THIS PRINT
.250 6.35
REF
No OF POSITIONS
-05, -07, -10, -15, -20, -25,
-30 -35 -40, -45, & -50 (PER ROW)
AVAILABLE AS STANDARD
-02 THRU -50 AVAILABLE AS ASO
WIRE GAUGE (AWG)
-28, -30
COLOR CODE:
LEAVE BLANK FOR ALL BLACK WIRE
C: COLOR CODED WIRE, SEE COLOR
SEQUENCE TABLE, SHEET 4
(NOT AVAILABLE WITH TEFLON OPTION)
PLATING SPECIFICATION
FLASH SELECTIVE
*
-F: LIGHT SELECTIVE
-L:
*
-S: SELECTIVE
*
-H: HEAVY GOLD
-G: LIGHT GOLD
-GF: FLASH GOLD
(SEE TABLE 4, SHEET 3)
.120 3.05 REF .145 3.68 REF
-NXX OPTION (END 2)
(ONLY AVAILABLE WITH -D, -DL, -DR)
-NUS: NOTCH UP, STRAIGHT
(PIN 1 TO PIN N-1)
-NDS: NOTCH DOWN, STRAIGHT
(PIN 1 TO PIN 2)
-NUX: NOTCH UP, CROSSED
(PIN 1 TO PIN N)
-NDX: NOTCH DOWN, CROSSED
(PIN 1 TO PIN 1)
02
N (SEE TABLE 2)
.080 2.03 REF
.050 1.27
REF
ISDF-XX-D
-S: SINGLE END
(SFSD-10-28-XX-XX.XX-S SHOWN)
FIG. 1
"A"
.050 1.27 REF
.440 11.18
REF
.249 6.32
REF
ASSEMBLED LENGTH
SPECIFY IN INCHES
(SINGLE END: 03.00 INCH [76.2mm] MINIMUM,
DOUBLE END: 03.25 INCH [82.6mm] MINIMUM)
END OPTION
(END OPTION COMBINATIONS NOT AVAILABLE)
-S: SINGLE END
-D: DOUBLE END
(MUST CHOOSE FROM -NXX OPTIONS)
-SL: SINGLE ENDED WITH FRICTION LOCK
(SEE SHEET 2, FIG. 3) (ONLY AVAILABLE
ON -10 THRU -30 POSITION)
-DL: DOUBLE ENDED WITH FRICTION LOCK
(SEE SHEET 2, FIG. 4) (ONLY AVAILABLE
ON -10 THRU -30 POSITION)
(MUST CHOOSE FROM -NXX OPTIONS)
-SR: SINGLE ENDED WITH RETENTION LATCH
(SEE SHEET 4, FIG. 5)(USE SUB-IM-LTC-07-01-N)
(ONLY AVAILABLE ON -05 THRU -30 POS)
-DR: DOUBLE ENDED WITH RETENTION LATCH
(SEE SHEET 4, FIG. 6)(USE SUB-IM-LTC-07-01-N)
(ONLY AVAILABLE ON -05 THRU -30 POS)
(MUST CHOOSE FROM -NXX OPTIONS)
*
DO NOT DESIGN IN.
NOT RELEASED FOR PRODUCTION
**
FOR EXISTING CUSTOMERS ONLY.
C1
ASSEMBLED LENGTH:
(SEE NOTE 8)
C2
ASSEMBLED LENGTH:
XX.XX .125[3.18]
DWCX-XX-XX-300
"A"
NOTES:
1.
C
REPRESENTS A CRITICAL DIMENSION.
2. MINIMUM PULLOUT FORCE: 3.0 LBS [13.3 N].
C3
3. CONTACT MUST BE INSERTED UNTIL
RETENTION FEATURE LOCKS INTO PLACE.
**
C4
4. ALL FINISHED GOODS ARE TO BE ELECTICAL
TESTED INCLUDING HI-POT TEST AT 1000 VOLTS DC.
**
5. TINNED COPPER WIRE IS RoHS COMPLIANT.
6. PARTS TO BE LAYER PACKAGED.
7. END OF DISCRETE WIRE MUST BE IN THE RANGE AFTER CRIMP.
8. FOR LENGTHS LESS THAN 12 in, TOLERANCE SHALL BE +/-.125.
FOR OTHER LENGTHS, TOLERANCE SHALL BE +/-2%.
9. NOTE DELETED.
10. SEE DWLX-08-XX-X-XX.XX-XX-XX FOR CRIMP DIMENSIONS.
11. 3LB MIN WIRE CRIMP STRENGTH FOR -30 AWG AND
L
4.5LB MIN WIRE CRIMP STRENGTH FOR -28 AWG.
SECTION "A"-"A"
-D: DOUBLE END
(SFSD-10-28-XX-XX.XX-D-NUS SHOWN)
(SAME AS FIG. 1, UNLESS OTHERWISE STATED)
FIG. 2
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
.XX: .01 [.3]
2
.XXX: .005 [.13]
.XXXX: .0020 [.051]
ANGLES
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
DESCRIPTION:
DWG. NO.
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 2:1
INSULATOR: LCP, COLOR: BLACK
CONTACT: BeCu
CABLE INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
.050[1.27] SOCKET DISCRETE CABLE ASSEMBLY
SFSDX-XX-XXX-XX-XX.XX-XX-XXX
BY:
BRATCHER 5/5/2005
SHEET
1
OF
4
F:\DWG\MISC\MKTG\SFSDX-XX-XXX-XX-XX.XX-XX-XXX-MKT.SLDDRW
I'm new to this. Please help me. I'd be grateful.
I want to know what is the difference between audio op amps and ordinary op amps. When should I use an audio op amp? When should I use an ordinary op amp? And when should I use a power amplifier?...
18663350860 Analog electronics
About BoolLoader self-programming (transfer)
1. The size of area A and area B can be changed by setting the fuse bit, but RWW and NRWW are fixed and will not change. For M8, the size of area B can be set to 128, 256, 512, 1024 words, while RWW/N...
fish001 MCU
Unable to download program using EVC4.0
I installed EVC4.0 and the standard SDK, but when generating the executable program, the program is prompted to have no errors, but the system prompts the following: An application targeting a Standar...
rebor03 Embedded System
Regarding the issue of using GAPI to write screen with TCPMP?
Dear experts: I am going to use Windows API to write an interface to call TCPMP's common.dll to make a player, but I also want to use GAPI to write the screen. Can you tell me how to do it? Should I c...
twentyone Embedded System
Analysis of RS485 Typical Circuit
[b]1. Introduction to RS485[/b] RS485 is a hardware interface or communication circuit or serial bus. Its signal is a signal that can effectively suppress common-mode signals. Therefore, its communica...
qwqwqw2088 Analogue and Mixed Signal
Shenzhen SEG Building closed after shaking, evacuees: chairs were obviously shaking
Shenzhen Special Zone Daily reported on May 18 that the landmark SEG Tower located in Huaqiangbei, Futian District, Shenzhen, shook and the office workers inside fled in a hurry. Regarding this incide...
eric_wang Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1280  1602  536  2494  1735  26  33  11  51  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号