Philips Semiconductors
Objective specification
Rectifier diode
fast, high-voltage
FEATURES
• Low forward volt drop
• Fast switching
• Soft recovery characteristic
• High thermal cycling performance
• Isolated mounting tab
BY359DX-1500
SYMBOL
QUICK REFERENCE DATA
V
R
= 1500 V
V
F
≤
1.5 V
I
F(AV)
= 10 A
I
FSM
≤
60 A
t
rr
≤
600 ns
k
1
a
2
GENERAL DESCRIPTION
Glass-passivated double diffused
rectifier diode featuring low forward
voltage drop, fast reverse recovery
and soft recovery characteristic.
The device is intended for use in TV
receivers, series resonant switched
mode power supplies and other
high voltage circuits.
The BY359DX series is supplied in
the conventional leaded SOD117
package.
PINNING
PIN
1
2
tab
DESCRIPTION
cathode
anode
isolated
SOD117
case
1
2
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134).
SYMBOL
V
RSM
V
RRM
V
RWM
I
F(AV)
I
F(RMS)
I
FRM
I
FSM
PARAMETER
Peak non-repetitive reverse
voltage
Peak repetitive reverse voltage
Crest working reverse voltage
Average forward current
RMS forward current
Peak repetitive forward current
Peak non-repetitive forward
current
I
2
t for fusing
Storage temperature
Operating junction temperature
CONDITIONS
MIN.
-
-
-
-
-
-
-
-
-
-40
-
MAX.
1500
1500
1300
10
20
60
60
66
18
150
150
UNIT
V
V
V
A
A
A
A
A
A
2
s
˚C
˚C
sinusoidal; a = 1.57; T
hs
= tbf
sinusoidal; a = 1.57
t = 10 ms
t = 8.3 ms
half sine wave; T
j
= 150 ˚C prior to
surge; with reapplied V
RWM(max)
t = 10 ms
I
2
t
T
stg
T
j
ISOLATION LIMITING VALUE & CHARACTERISTIC
T
hs
= 25 ˚C unless otherwise specified
SYMBOL
V
isol
PARAMETER
R.M.S. isolation voltage from
both terminals to external
heatsink
CONDITIONS
f = 50-60 Hz; sinusoidal
waveform;
R.H.
≤
65% ; clean and dustfree
MIN.
-
TYP.
MAX.
2500
UNIT
V
C
isol
Capacitance from both terminals f = 1 MHz
to external heatsink
-
10
-
pF
April 1998
1
Rev 1.000
Philips Semiconductors
Objective specification
Rectifier diode
fast, high-voltage
THERMAL RESISTANCES
SYMBOL
R
th j-hs
R
th j-a
PARAMETER
Thermal resistance junction to
heatsink
Thermal resistance junction to
ambient
CONDITIONS
with heatsink compound
without heatsink compound
in free air.
MIN.
-
-
-
BY359DX-1500
TYP.
-
-
tbf
MAX.
tbf
tbf
-
UNIT
K/W
K/W
K/W
STATIC CHARACTERISTICS
T
j
= 25 ˚C unless otherwise stated
SYMBOL
V
F
I
R
PARAMETER
Forward voltage
Reverse current
CONDITIONS
I
F
= 20 A
I
F
= 10 A; T
j
= 150˚C
V
R
= 1300 V
V
R
= 1300 V; T
j
= 100 ˚C
MIN.
-
-
-
-
TYP.
1.3
1.00
10
50
MAX.
1.8
1.5
100
300
UNIT
V
V
µA
µA
DYNAMIC CHARACTERISTICS
T
j
= 25 ˚C unless otherwise stated
SYMBOL
t
rr
Q
s
V
fr
PARAMETER
Reverse recovery time
Reverse recovery charge
Peak forward recovery voltage
CONDITIONS
I
F
= 2 A; V
R
≥
30 V; -dI
F
/dt = 20 A/µs
I
F
= 2 A; V
R
≥
30 V; -dI
F
/dt = 20 A/µs
I
F
= 10 A; dI
F
/dt = 30 A/µs
MIN.
-
-
-
TYP.
0.47
1.6
11.0
MAX.
0.6
2.0
-
UNIT
µs
µC
V
April 1998
2
Rev 1.000
Philips Semiconductors
Objective specification
Rectifier diode
fast, high-voltage
MECHANICAL DATA
Dimensions in mm
Net Mass: 5.9 g
BY359DX-1500
16.0 max
0.7
4.5
10.0
27
max
25.1
25.7
22.5
max
5.1
2.2 max
18.1
min
1.1
0.4 M
2
10.9
3.3
5.8 max
3.0
25
0.9 max
3.3
Fig.1. SOD117; The seating plane is electrically isolated from all terminals.
Notes
1. Refer to mounting instructions for F-pack envelopes.
2. Epoxy meets UL94 V0 at 1/8".
April 1998
3
Rev 1.000
Philips Semiconductors
Objective specification
Rectifier diode
fast, high-voltage
DEFINITIONS
Data sheet status
Objective specification
Product specification
Limiting values
BY359DX-1500
This data sheet contains target or goal specifications for product development.
This data sheet contains final product specifications.
Preliminary specification This data sheet contains preliminary data; supplementary data may be published later.
Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one
or more of the limiting values may cause permanent damage to the device. These are stress ratings only and
operation of the device at these or at any other conditions above those given in the Characteristics sections of
this specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
©
Philips Electronics N.V. 1998
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the
copyright owner.
The information presented in this document does not form part of any quotation or contract, it is believed to be
accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any
consequence of its use. Publication thereof does not convey nor imply any license under patent or other
industrial or intellectual property rights.
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices or systems where malfunction of these
products can be reasonably expected to result in personal injury. Philips customers using or selling these products
for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting
from such improper use or sale.
April 1998
4
Rev 1.000