EEWORLDEEWORLDEEWORLD

Part Number

Search

F.MF.01A.07.20.FC

Description
Mains Power Connector, 1A, 250VAC, Male, Solder Terminal
CategoryThe connector    The connector   
File Size718KB,3 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

F.MF.01A.07.20.FC Overview

Mains Power Connector, 1A, 250VAC, Male, Solder Terminal

F.MF.01A.07.20.FC Parametric

Parameter NameAttribute value
MakerKEMET
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320, CSA, UL, VDE
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings1A, 250VAC
Manufacturer's serial numberF.MF
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
IEC Inlet Filters
With fuse holders and voltage selectors
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus input voltage selector
with 4 possible combinations. These features ensure the range is
ideally suited for manufacturers of business, consumer and medical
equipment for international markets.
F.MF-F.MG
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Voltage selector
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320, 1 (F.MF) or 2 (F.MG) fuse
holders for fuses 5 x 20mm (IEC) or 6.3 x 32mm
(US), voltage selector with 4 possible combinations;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 2.8 x 0.5mm for voltage selector terminals;
ground terminal connected to case.
F.MF.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MG. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MF.01A.01.01.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Voltage selector:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
110-220-240Vac
100-120-220-240Vac
115-115-230-230Vac
110-220Vac
Leakage current (I
L
):
at 220V, 50Hz, max value
F = 1 fuse
G = 2 fuses
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
01 = fuse 5 x 20mm + voltage selector 110-220-240V~
02 = fuse 5 x 20mm + voltage selector 100-120-220-240V~
03 = fuse 5 x 20mm + voltage selector 115-115-230-230V~
08 = fuse 6.3 x 32mm + voltage selector 110-220-240V~
09 = fuse 6.3 x 32mm + voltage selector 100-120-220-240V~
10 = fuse 6.3 x 32mm + voltage selector 115-115-230-230V~
15 = fuse 5 x 20mm + voltage selector 110-220V~
16 = fuse 6.3 x 32mm + voltage selector 110-220V~
19 = fuse 5 x 20mm + voltage selector 100-120-220-230V~
20 = fuse 6.3 x 32mm + voltage selector 100-120-230-240V~
21 = fuse 5 x 20mm + voltage selector 100-120-230-240V~
Approvals
29
Help: Error in calling external program using ShellExecuteEx in EVC
On WinCE4.2, EVC++4.0 is used. Clicking a button calls an external program. The problem is that I can call the external program normally using the Debug version, but there is no response when using th...
yglcncm Embedded System
ST-Ecovacs Automatic Sweeping Robot Disassembly and Evaluation Report
[align=left]ST-[font=黑体]Ecovacs Automatic Sweeping Robot[/font][/align][align=left]Disassembly and Evaluation Report[/align] [table] [tr][td=121][align=center][align=left]Document No.[/align][/align][...
mars4zhu Robotics Development
Qorvo explains WIFI and 5G clearly
In the field of wireless communications, there have always been two ways of connection: one is the cellular network, namely 2/3/4/5G, and the other is Wi-Fi technology, IEEE 802.11 a/b/g/n/ac/ax. At p...
btty038 RF/Wirelessly
Blue Bridge Cup Embedded Real Questions
Dear experts, if anyone has the real questions from the provincial and final competitions of the Blue Bridge Cup Embedded System, please send me a copy. I have searched many websites but couldn't find...
MHB_520 Electronics Design Contest
Development of wireless temperature monitoring technology for thermal protection systems
[b]1 Introduction[/b] Replacing the aging space shuttle fleet with a competitive commercial reusable launch vehicle (RLV) is a major goal of NASA and the U.S. aerospace industry [1]. To achieve this g...
Test/Measurement
NUCLEO-G431RB Review Using the Library to Do FFT
[i=s]This post was last edited by viphotman on 2019-10-10 16:24[/i]NUCLEO-G431RB Evaluation FFTFile Location There are ARM library files in STM32CubeG4_V1.1.0\STM32Cube_FW_G4_V1.0.0\Drivers\CMSIS\Lib\...
viphotman stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1497  1041  14  1731  1216  31  21  1  35  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号