EEWORLDEEWORLDEEWORLD

Part Number

Search

891-005-15CSS-0A1-12

Description
Interconnection Device
CategoryThe connector    The connector   
File Size224KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

891-005-15CSS-0A1-12 Overview

Interconnection Device

891-005-15CSS-0A1-12 Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
891-005
Series 89 Nanominiature Connectors
Double Row Back-To-Back
Glenair’s Back-To-Back Nano Connectors
feature gold
alloy TwistPin contacts. Contacts are precision-crimped
to insulated, stranded wire. These nanomimiature
connectors offer premium preformance and reliability for
demanding applications. Contact spacing is .025 inches.
1 amp current rating, DWV rating 300 volts AC. Wire
gages #30 and #32 AWG.
TwistPin Contact System
assures premium performance in
demanding environments. The gold/platinum alloy contacts
will stand up to years of exposure without corrosion.
HOW TO ORDER DOUBLE ROW BACK-TO-BACK JUMPERS
Series
Number of Connector
Contacts
Type
9
15
21
25
31
37
51
GP
Shell Material
and Finish
A1
Wire
Gage
0
Wire Type
Wire
Color
Code
1
White
Length
Inches
Overall
Length
In Inches
Hardware
891-005
Back-To-
Back Cables,
Double Row,
Nanominiature
A
Ultralightweight
XLETFE Insulation,
Silver-Coated
Ultrahigh-Strength
Copper (Not available
for #32 AWG)
JJ
= Jackscrews on
both ends (GP, GS, CS)
Plug (Pin)
Aluminum Shell, #30 AWG
Connector on Cadmium Plating
Both Ends
JT
= Jackscrews on
Including
Connectors
JP
= Jackscrews on
plug, threaded holes on
receptacle (CS)
2
2
Yellow
A2
GS
Receptacle
(Socket)
Connector on
Both Ends
Aluminum Shell,
Electroless
Nickel Plating
#32 AWG
7
B
Extruded PTFE
Insulation, NEMA HP3-
ETX (MIL-W-16878/6)
10 Color
Repeating
(wire
type A is
striped,
types B
and C
are solid
colors)
Example:
“12”
specifies
12 inches
OAL
plug, threaded holes on
plug (GP)(*See Note
Below)
TJ
= Jackscrews on
receptacle, threaded
holes on plug
(CS)(*See Note Below)
T
CS
Plug (Pin)
On One End,
Receptacle On
The Other End
Titanium Shell,
Unplated
C
S
Stainless Steel
Shell, Passivated
Cross-Linked Modified
ETFE Insulation, MIL-
W-22759/33
(Not available for #32
AWG)
JR
= Jackscrews on
receptacle, threaded
holes on receptacle
(GS)
TT
= Threaded holes
both ends (GP, GS,
CS)(*See Note Below)
* Specify titanium or
stainless steel shells
when ordering plugs
with female threads.
Sample Part Number
891-005
— 9
GP
A1
—0
A
1
— 12
J
PLUG (PIN) CONNECTOR
RECEPTACLE (SOCKET) CONNECTOR
“J” Jackscrew Option
“T” Female Thread Option
Titanium or Stainless Steel
Shells Only
“T” Female Thread Option
“J” Jackscrew Option
© 2007 Glenair, Inc.
CAGE Code 06324/0CA77
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
39
E-Mail: sales@glenair.com
Double Row
Connectors
[Power Supply Q&A] + Best Design of Switching Power Supply
1. The switching power supply has few components but requires precision. There are several important issues in the design: A. Transformer design and selection? b. EMC issues to pay attention to C. Eff...
samhuang8204 Analogue and Mixed Signal
Longing for that piece of pure land - [Daocheng Yading]
It is said that in a hidden place deep in the snow-capped mountains of the Qinghai-Tibet Plateau, there is a kingdom surrounded by double-layer snow-capped mountains, where there are snow-capped mount...
lixiaohai8211 Talking
A continuously adjustable regulated power supply
Adjustable regulated power supply...
huacong5419 FPGA/CPLD
Ask about the electric control question
I want the microcontroller to output a PWM signal to drive a brushless motor through an ESC. Is the frequency of the brushless ESC control signal only 50HZ? Why does my ESC need to be recalibrated onc...
18772806353 NXP MCU
[FM33LG0 series development board evaluation] 02. Basic engineering (LED, KEY, LPUART, LPTIM, SHELL)
After preparing the development materials and setting up the development environment, we will prepare a basic project; good infrastructure is the key to building a high-rise building, so the original ...
xld0932 Domestic Chip Exchange
Application of serial port server in centralized management of factory scales
A large cement plant has multiple sets of electronic floor scales and computer measurement systems. Since all floor scales are serial devices and cannot be connected over long distances, the measureme...
warrant417 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2624  2820  1356  417  1562  53  57  28  9  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号