EEWORLDEEWORLDEEWORLD

Part Number

Search

5431.4253.253

Description
Mains Power Connector, 4A, 250VAC, Female and Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size403KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5431.4253.253 Overview

Mains Power Connector, 4A, 250VAC, Female and Male, Solder Terminal, ROHS COMPLIANT

5431.4253.253 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARD: IEC/EN 60320-1/C14, UL 498; UL 94V-0, CSA C22.2, VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderFEMALE AND MALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings4A, 250VAC
Manufacturer's serial number54
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts6
Power Entry Modules with Line Filter
www.schurter.com/PG06
IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54
Standard- or Medical-Filter
Snap-In Version
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
Description
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fu-
seholder for fuse-links 5␠x␠20␠mm 1␠ or 2␠pole, Line filter in standard
and medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
Characteristics
Approvals
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
- VDE Certificate Number: 101307
- UL File Number: E72928
Other versions on request
References
Weblinks
- Line switch with other rocker marking
Alternative: version without line filter
Felcom 64
Alternative: Standard version
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-
Drawings, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.
5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC 60320,
F acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C,
10 A, Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard Version, IEC 60939, UL 1283,
CSA C22.2 no. 8
Technical Details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
Connectors
1
Can I use Target Server after the target machine's hard disk boots vxWorks?
I booted vxWroks from the target machine's hard disk and configured the communication network port between the target machine and the host machine. The DEFAULT_BOOT_LINE structure is as follows; "ata=...
Jonsen_yang Embedded System
Snapdragon 845 CPU
How to buy Xiaolong 845 CPU directly?...
2716261560 Buy&Sell
Practical Circuit Diagram Analysis
Can you analyze this circuit? Since I am new to analog electronics, I don't know much about transistors. Why do the two transistors turn on in turn when the light is dim, and the LED flashes?Please an...
柳飘飘 Analog electronics
Application of ACM in power distribution overload monitoring device
Abstract: This paper focuses on the principle, characteristics and main parameters of the ACM distribution line overload monitoring device, that is, by detecting the current in the distribution line, ...
acrel008 Power technology
SMS
Have you noticed that when you use more than two mobile phones, you will see that the number of words in a message sent by the two phones is different? I don’t know if China Mobile and China Unicom ha...
heningbo Talking
I want to use wireless to achieve such a function, everyone take a look
I have two identical data acquisition devices at two locations. Now I want to synchronize the data acquisition via wireless. That is, one device sends a data acquisition command and starts data acquis...
ogmwyv Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1604  284  1500  2586  1978  33  6  31  53  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号