MICD-038-27.98-TEU-STL-1

Description
Interconnection Device, LEAD FREE
CategoryThe connector    The connector   
File Size2MB,6 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

MICD-038-27.98-TEU-STL-1 Overview

Interconnection Device, LEAD FREE

MICD-038-27.98-TEU-STL-1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSAMTEC
package instructionLEAD FREE
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
REVISION G
VERTICAL
(MICD-038-XX.XX-STR-STR-1 SHOWN)
FIG. 1
MICD-XXX-XX.XX-XXX-XXX-X-X
No OF POSITIONS
-019, -038, -057, -076, -095
(PER ROW)
LENGTH
-XX.XX (INCHES)
(03.75[95.3] MIN)
(SEE NOTE 2)
(SEE NOTE 8)
END OPTION
-F: SCREW OPTION FIRST END ONLY
-S: SCREW OPTION SECOND END ONLY
-B: SCREW OPTION BOTH ENDS
-N: NO CAPS
(SEE FIG. 3, SHEET 5 FOR EDGE MOUNT
END OPTIONS)
(SEE FIG. 4, SHEET 5 FOR DOUBLE
VERTICAL END OPTIONS)
(SEE FIG. 5, SHEET 5 FOR NO CAPS OPTIONS)
(LEAVE BLANK FOR STANDARD CAPS
BOTH ENDS)
WIRING OPTION
-1: PIN 1 TO PIN 1
-2: PIN 1 TO PIN 2
-3: PIN 1 TO PIN N-1
-4: PIN 1 TO PIN N
(SEE TABLE 9, SHEET 6)
SECOND END
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 3)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
LENGTH: XX.XX + "L" REF (SEE TABLE 4)
SUB-MICD-X-XXX-XX
N (SEE TABLE 3)
C1
LENGTH: XX.XX
N-1
(SEE TABLE 3)
01%
N
(SEE TABLE 3)
N-1 (SEE TABLE 3)
FIRST END
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 2)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
DO NOT
SCALE FROM
THIS PRINT
"A" REF
(TYP)
"B" REF
(TYP)
'A'
SUB-MICD-X-XXX-XX
1
2
.570 14.49
REF (TYP)
.845 21.47
REF (TYP)
ICD-XX-01
2
HDRL-11
(SEE NOTE 5)
STS-01
(TIGHTEN TO 1.4 - 1.7 IN-LBS)
(4 PLCS)
SUB-TCF-3850-19-01-XX.XX
(SEE TABLE 1 FOR QTY)
1
FIRST END
SECOND END
ICD-XX-01
LENGTH
REF
.292 7.42 REF (TYP)
NOTES:
* "C" REF
C2
C3
G
ICD-XX-02
1.
C
REPRESENTS A CRITICAL DIMENSION.
2. SUB-TCF LENGTH IS EQUAL TO MICD LENGTH.
3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED.
4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V.
5. TOP SUB-TCF NOT SHOWN IN THIS VIEW FOR CLARITY; HDRL-11
TO BE CENTERED ON LOWER SUB-TCF AS SHOWN; HDRL-11 IS
TO CONTAIN PART NUMBER, SHOP NUMBER, & DATE CODE.
6. FOR SUB-ASSEMBLY AND FINISHED GOOD PACKAGING REQUIREMENTS,
REFERENCE PACKAGING STANDARD CO-HD-WI-3033-M.
7. PARTS TO BE PROCESSED PER SAMTEC ACCEPTABILITY REQUIREMENTS:
HDR-PI-01 "CABLE ASSEMBLY WORKMANSHIP STANDARDS".
8. CABLE LENGTHS LONGER THAN 40.00 INCHES ARE NOT SUPPORTED BY
S.I. TEST DATA.
ICD-XX-02
DETAIL 'A'
SCALE 2.5 : 1
Pb
THIS PRODUCT MANUFACTURED
WITH LEAD-FREE PROCESSING
* -DV END OPTIONS ONLY
TOLERANCES DO NOT APPLY
TO REFERENCE DIMENSIONS.
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
ANGLES
.XX: .01[.3]
2
.XXX: .005[.13]
.XXXX: .0020[.051]
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
DESCRIPTION:
DWG. NO.
DO NOT SCALE DRAWING
SHEET SCALE: 1.25:1
0.635 HIGH-SPEED COAX CABLE ASSEMBLY
MICD-XXX-XX.XX-XXX-XXX-X-X
12/11/03
SHEET
1
OF
6
F:\DWG\MISC\MKTG\MICD-XXX-XX.XX-XXX-XXX-X-X-MKT.SLDDRW
BY:
KEVIN B
Have you ever come into contact with intrinsically safe power supply design? Is there a 2A24V power supply solution?
RT, has anyone ever come into contact with the design of intrinsically safe power switches? Is there any solution for the design of a 2A, 24V output power supply? Please share with me....
哼哼哈嘿丨墨染 Power technology
Please teach me a Verilog program!
dram dram = dram.clk_in(clk_10mb),.clk_out(clk_out)); half_clk b(.clk_in(clk_10mb),.clk_out(clk_out)); dram = dram.clk_in(clk_10mb),.clk_out(clk_out)); dram = dram.clk_out(clk_10mb),.clk_out(clk_out))...
lingfeng Embedded System
Question: STM's 16 high current drivers
Question: For the 16 high-current high-level drive optocouplers of STM, should they be connected in series with a resistor or a pull-up resistor?Another question: When using a timer, can the port corr...
maxipeiz stm32/stm8
Periodic feedback pure digital phase-locked loop based on actel fpga
[i=s]This post was last edited by teleagle on 2018-10-8 22:19[/i] [b][color=#000000] [/color][/b][color=#000000]A periodic feedback pure digital phase-locked loop based on actel FPGA: [/color][color=#...
teleagle FPGA/CPLD
Embedded AMR Tsinghua University Training Course
Embedded AMR Tsinghua University Training Course...
呱呱 MCU
What does this circuit do?
This is a drawing of a single power supply circuit. When dual power supply is used, the ground is generally changed to a negative power supply. I have never understood its specific function. Please he...
yyd0311 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1635  1494  2615  1813  2406  33  31  53  37  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号