EEWORLDEEWORLDEEWORLD

Part Number

Search

PB02W-601ISNT

Description
Mains Power Connector, 2A, 115/250VAC, Male, Socket
CategoryThe connector    The connector   
File Size345KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

PB02W-601ISNT Overview

Mains Power Connector, 2A, 115/250VAC, Male, Socket

PB02W-601ISNT Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARD: IEC 60320
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2A, 115/250VAC
Manufacturer's serial numberPB
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
PB Series
STRAIGHT, SNAP-IN/FLANGE MOUNT FILTER WITH IEC 60320
AC INLET SOCKET.
MECHANICAL DIMENSIONS
(Unit: mm)
FLANGE MOUNT
50.1
30.3
22.5
40.0
28.5
4-R5
21.6
2-
3.3
40.0
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
45.5
46.8
41.4
55.8
G
28.3
20.6
SNAP-IN (SNT)
FEATURES
31.0
The PB series, similar to PA and PASP series, offers filters with
IEC connector providing effective equipment protection of
line-to-ground noise up to 15 Amp, 250VAC. The compact
design filter with low leakage current is well suited for
applications that require strict national and international
emission standards. These filters are also available for
Medical application and offer extremely low Leakage current
to comply with UL544, UL2601 and CSA22.2 standards.
A ground choke can be added to enhance the grounding
ability of the circuit. Bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
55.2
43.6
24.0
21.9
21.2
4-R2
28.5
4-R2
29.6
SUGGESTED PANEL CUTOUT** SUGGESTED PANEL CUTOUT**
(MOUNTING FROM FRONT)
(MOUNTING FROM FRONT)
SNT Option
SSI Option
3.75
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
28.3
20.6
FLANGE MOUNT (B)
52
40
40.0
28.5
4-R5
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 6A, 8A, 10A, 15A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application; ** Thickness of Panel is from 1.00mm to 1.6mm
25
2-
3.3
3.5
21.6
30.3
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
45.5
46.8
41.4
55.8
G
28.3
20.6
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
8
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
Help: Share your experience in selecting oscilloscopes, power supplies, multimeters and other equipment
Our school is currently planning to open the School of Electronic Information next year. We will add a batch of new laboratory equipment, mainly including frequency meters, digital multimeters, oscill...
新人不新 Buy&Sell
[Play ESP8266 together] Practice adding the path derived under putty
[i=s]This post was last edited by sacq on 2016-8-28 16:24[/i] I didn’t notice it a few days ago, but the moderator has already released a new tutorial (6): [url=https://bbs.eeworld.com.cn/thread-49756...
sacq MicroPython Open Source section
I developed an OCX. How can I register it on the PDA? How can I use the program to achieve this?
I developed an OCX. How can I register it on the PDA? How can I use the program to achieve it? What resources do I need?...
pipingtom Embedded System
【TI course sharing】+BLE learning process!
I have always wanted to learn about BLE. There is a big difference between BLE and ordinary IC Bluetooth. The hardware is very small, and there may be fewer channels and lower power. The test methods ...
samhuang8204 Wireless Connectivity
LM3S9B96 sends data to PC via CAN?
LM3S9B96 sends data to PC via CAN. If the PC uses USB port, do I need to buy a CAN to USB card? If I don't use CAN but use Ethernet directly, what should I buy? Or can I just connect the Ethernet cabl...
喜鹊王子 TI Technology Forum
Timer
TBCCTL0 = CCIE; // TRCCR0 interrupt ena××edTBCCR0 = 1000-1;TBCTL = TBSSEL_1 + MC_1; // ACLK,why is TBCCR0 = 1000 instead of TBCCR0 = 1000-1 in up mode? Is it a special case in up counting mode?...
xihai Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2156  762  2310  1571  2914  44  16  47  32  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号