TMA50A

Description
CURRENT TRANSDUCER OPEN LOOP 50A
File Size149KB,2 Pages
ManufacturerMulticomp
Download Datasheet Compare View All

TMA50A Overview

CURRENT TRANSDUCER OPEN LOOP 50A

Current Transducer
Hall Effect
Features:
Highly reliable hall effect device.
Compact and light weight.
Fast response time.
Excellent linearity of the output voltage over a wide input range.
Excellent frequency response (> 50 KHz).
Low power consumption (12 mA nominal).
Capable of measuring both DC and AC, both pulsed and mixed.
High isolation voltage between the measuring circuit and the current-carrying conductor
(2.5 KV ac).
Extended operating temperature range.
Flame-Retardant plastic case and silicone encapsulate, using UL classified materials, ensures
protection against environmental contaminants and vibration over a wide temperature and
humidity range.
Applications
UPS systems.
Industrial robots.
NC tooling machines.
Elevator controllers.
Process control devices.
AC and DC servo systems.
Motor speed controller.
Electrical vehicle controllers.
Inverter-controlled welding machines.
General and special purpose inverters.
Power supply for laser processing machines.
Controller for traction equipment eg. electric trains.
Other automatic control systems.
Specification Table
Parameter
Nominal Input Current
Linear Range
Nominal Output Voltage
Offset Voltage
Output Resistance
Hysteresis Error
Supply Voltage
Linearity
Consumption Current
Response Time (90% V
hn
)
Frequency Bandwidth (-3dB)
Thermal Drift of Output
Thermal Drift of Zero Current Offset
Dielectric Strength
Isolation Resistance 1,000 V dc
Symbol
I
fn
I
fs
V
hn
V
os
R
OUT
V
oh
V
CC
/ V
EE
ρ
I
CC
T
r
f
BW
-
-
-
R
IS
Unit
A dc
V
mV
mV
V
%
mA
µs
Hz
% / °C
mV / °C
V
MΩ
TMA50A
±50
±150
TMA100A
±100
±300
TMA200A
±200
±600
TMA400A
±400
±900
4 V ±1% at If = I
fn
(R
L
= 10 KΩ)
Within ±40 mV at I
f
= 0, T
a
= 25°C
< 100
Within ±20 mV at I
f
= I
fn
0
±15 V ±5%
Within ±1% of I
fn
±15 mA Max.
10 µs at d I
f
/ dt = I
fn
/ µs
DC to 50 KHz
Within ±0.1% / °C at I
fn
Within ±1.5 mV / °C at I
fn
2.5 KV ac × 60 s
> 1,000 MΩ
www.element14.com
www.farnell.com
www.newark.com
Page <1>
06/06/11 V1.1

TMA50A Related Products

TMA50A TMA200A TMA100A TMA400A
Description CURRENT TRANSDUCER OPEN LOOP 50A CURRENT TRANSDUCER OPEN LOOP 200A CURRENT TRANSDUCER OPEN LOOP 100A CURRENT TRANSDUCER OPEN LOOP 400A

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 848  2195  207  597  426  18  45  5  13  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号