COIL POWER(AC) IS 7225 MILLIWATTS; COIL OPERATE VOLTAGE(AC): 204 V, COIL RELEASE VOLTAGE(AC): 24 V
Maximum adjustable time delay
1080000 s
Minimum adjustable time delay
0.05 s
body width
22.5 mm
body height
78 mm
Body length or diameter
80 mm
Coil current (AC) maximum value
0.03 A
Maximum coil current (DC)
0.025 A
Coil operating voltage (DC)
40.8 V
Coil power
1200 mW
Coil release voltage (DC)
4.8 V
Coil resistance
1920 Ω
Maximum coil voltage (AC)
240 V
Maximum coil voltage (DC)
48 V
Coil/Input Power Type
AC/DC
Maximum contact voltage (AC)
250 V
Maximum contact voltage (DC)
250 V
Installation features
DIN RAIL/PANEL MOUNT
Maximum operating temperature
60 °C
Minimum operating temperature
-20 °C
physical size
80mm x 22.5mm x 78mm
Guideline
CE; CSA; GL; IEC; UL
Relay action
MOMENTARY
Relay function
SPDT
Relay type
INTERVAL-DELAY RELAY
seal
IP20; IP50; MOISTURE PROOF
surface mount
NO
Termination type
SNAP-ON/SCREW
RE7CV11BU Preview
Product data sheet
Characteristics
RE7CV11BU
asymmetrical flashing relay - 0.05..1 s - 24 V
AC DC - 1OC
Main
Range of product
Product or component
type
Component name
Time delay type
Zelio Time
Industrial timing relay
RE7
L
Li
Lt
0.05 s...300 h
Time delay range
Complementary
Discrete output type
Contacts material
Width pitch dimension
[Us] rated supply voltage
Relay
90/10 silver nickel contacts
22.5 mm
42...48 V AC/DC at 50/60 Hz
24 V AC/DC at 50/60 Hz
110...240 V AC at 50/60 Hz
0.85...1.1 Us
Screw terminals, clamping capacity: 2 x 2.5 mm² flexible without cable end
Screw terminals, clamping capacity: 2 x 1.5 mm² flexible with cable end
0.6...1.1 N.m
+/- 10 % of full scale
+/- 0.2 %
< 0.07 %/°C
< 0.2 %/V
20 ms
50 ms
250 V AC/DC
20000000 cycles
8A
<= 3 A AC-15 at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660
<= 0.2 A DC-13 115 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660
<= 0.1 A DC-13 250 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660
<= 2 A DC-13 24 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660
12 V / 10 mA
< 60 V X2Z2 terminal(s)
< 60 V X1Z2 terminal(s)
1 mA X2Z2 terminal(s)
1 mA X1Z2 terminal(s)
3/4 wires sensors PNP/NPN without internal load, cable length: <= 50 m X2Z2
terminal(s)
3/4 wires sensors PNP/NPN without internal load, cable length: <= 50 m X1Z2
terminal(s)
Linear 47 kOhm (+/- 20 %), 0.2 W, cable length: <= 25 m Z1Z2terminal(s)
CE
III conforming to IEC 60664-1
300 V between contact circuit and power supply CSA certified
300 V between contact circuit and control inputs CSA certified
250 V between contact circuit and power supply IEC certified
250 V between contact circuit and control inputs IEC certified
Voltage range
Connections - terminals
Tightening torque
Setting accuracy of time delay
Repeat accuracy
Temperature drift
Voltage drift
Minimum pulse duration
Reset time
Maximum switching voltage
Mechanical durability
[Ith] conventional free air thermal current
[Ie] rated operational current
Minimum switching capacity
Input voltage
Maximum switching current
Input compatibility
Potentiometer characteristic
Marking
Overvoltage category
[Ui] rated insulation voltage
May 9, 2016
1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Supply disconnection value
Operating position
Surge withstand
Power consumption in VA
> 0.1 Uc
Any position without derating
2 kV conforming to IEC 61000-4-5 level 3
8.5 VA 240 V
1.8 VA 110 V
1.6 VA 48 V
0.7 VA 24 V
1.2 W 48 V
0.5 W 24 V
(15-16-18)OC_OFF
(B1-A2)CO
ALT
78 mm
22.5 mm
80 mm
0.15 kg
Power consumption in W
Terminal description
Height
Width
Depth
Product weight
Environment
Immunity to microbreaks
Standards
Product certifications
3 ms
EN/IEC 61812-1
CSA
GL
UL
-40...85 °C
-20...60 °C
15...85 % (3K3) conforming to IEC 60721-3-3
0.35 mm (f = 10...55 Hz) conforming to IEC 60068-2-6
15 gn for 11 ms conforming to IEC 60068-2-27
IP50 (housing)
IP20 (terminals)
3 conforming to IEC 60664-1
2.5 kV
4.8 kV
8 kV (in air) conforming to IEC 61000-4-2 level 3
6 kV (in contact) conforming to IEC 61000-4-2 level 3
10 V/m conforming to IEC 61000-4-3 level 3
2 kV conforming to IEC 61000-4-4 level 3
CISPR 11 group 1 - class A
CISPR 22 - class A
Ambient air temperature for storage
Ambient air temperature for operation
Relative humidity
Vibration resistance
Shock resistance
IP degree of protection
Pollution degree
Dielectric strength
Non-dissipating shock wave
Resistance to electrostatic discharge
Resistance to electromagnetic fields
Resistance to fast transients
Disturbance radiated/conducted
2
Product data sheet
Dimensions Drawings
RE7CV11BU
Width 22.5 mm
Rail Mounting
Screw Fixing
3
Product data sheet
Connections and Schema
RE7CV11BU
Internal Wiring Diagram
Recommended Application Wiring Diagram
Selection of Starting Phase
1
2
3
6
Supply
12…48 V
24 V
Start during the On-delay period: X2, Z2 linked.Start during the Off-delay period: X2, Z2 not linked.
Control of Several Relays
Control of several relays with a single external control contact
Connection of an External Control Contact Without Using Terminal Z2
Direct current supply only.
It is advisable to follow the recommended wiring schemes detailed above if the restrictions given are taken into account.
Direct current supply only.
It is advisable to follow the recommended wiring schemes detailed above if the restrictions given are taken into account.
Connection 3-Wire NPN or PNP Sensor
4
Connection 3-Wire NPN or PNP Sensor Without Using Terminal Z2
Connection NPN
It is advisable to follow the recommended wiring schemes detailed above if the restrictions given are taken into account.
Connection PNP
It is advisable to follow the recommended wiring schemes detailed above if the restrictions given are taken into account.
Connection of Potentiometer
7
8
Off-delay adjustment (tr) (contact 15/16 closed).
On-delay adjustment (ta) (contact 15/18 closed).
Connection Precautions
WARNING
UNEXPECTED EQUIPMENT OPERATION
No galvanic isolation between supply terminals and control inputs.
Failure to follow these instructions can result in death, serious injury, or equipment damage.