Description
Wire And Cable,
CategoryThe connector    Connector bracket   
File Size93KB,2 Pages
ManufacturerBELDEN
Environmental Compliance
Download Datasheet Parametric Compare View All

884420021000 Overview

Wire And Cable,

884420021000 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerBELDEN
Reach Compliance Codecompliant
Connector bracket typeWIRE AND CABLE

884420021000 Preview

Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
88442 Multi-Conductor - Audio, Control and Instrumentation Cable
For more Information
please call
1-800-Belden1
General Description:
22 AWG stranded (7x30) tinned copper conductors, plenum, FEP insulation, twisted pairs, FEP jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1
22
7x30
TC - Tinned Copper
2
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Material
Wall Thickness (in.)
FEP - Fluorinated Ethylene Propylene 0.007
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
FEP - Fluorinated Ethylene Propylene 0.009
Overall Cable
Overall Nominal Diameter:
0.102 in.
Pair
Pair Color Code Chart:
Number Color
1
Black & Red
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-70°C To +200°C
8 lbs/1000 ft.
15 lbs.
1.250 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CMP
CMP
Yes
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
NFPA 262
Page 1 of 2
07-23-2014
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
88442 Multi-Conductor - Audio, Control and Instrumentation Cable
UL Flame Test:
CSA Flame Test:
NFPA 262
FT6
Suitability
Suitability - Outdoor:
Suitability - Burial:
Yes
Yes
Plenum/Non-Plenum
Plenum (Y/N):
Non-Plenum Number:
Yes
8442
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/ft)
.15
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
17
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
15
Nominal Conductor Loop Resistance:
Resistance @ 20°C (Ohm/1000 ft)
30
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
3.3 Amps per conductor @ 25°C (10°C rise in temp)
Put Ups and Colors:
Item #
88442 002100
88442 0021000
88442 002500
Notes:
C = CRATE REEL PUT-UP.
Putup
100 FT
1,000 FT
500 FT
Ship Weight
2.300 LB
9.000 LB
5.500 LB
Color
RED
RED
RED
C
C
Notes
Item Desc
2#22 FEP FEP
2#22 FEP FEP
2#22 FEP FEP
Revision Number: 2
© 2014 Belden, Inc
All Rights Reserved.
Revision Date: 08-31-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 2 of 2
07-23-2014

884420021000 Related Products

884420021000 88442002100
Description Wire And Cable, Wire And Cable,
Is it Rohs certified? conform to conform to
Maker BELDEN BELDEN
Reach Compliance Code compliant compli
Connector bracket type WIRE AND CABLE WIRE AND CABLE

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2031  2005  832  271  93  41  17  6  2  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号