EEWORLDEEWORLDEEWORLD

Part Number

Search

100USC1500MSN22X35

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 100V, 20% +Tol, 20% -Tol, 1500uF, Through Hole Mount, CAN, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size247KB,4 Pages
Manufacturerrubycon
Websitehttp://www.rubycon.co.jp/cn/
Environmental Compliance
Download Datasheet Parametric View All

100USC1500MSN22X35 Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 100V, 20% +Tol, 20% -Tol, 1500uF, Through Hole Mount, CAN, ROHS COMPLIANT

100USC1500MSN22X35 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Makerrubycon
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance1500 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
diameter22 mm
dielectric materialsALUMINUM (WET)
JESD-609 codee3
leakage current1.1619 mA
length35 mm
Manufacturer's serial numberUSC
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Package shapeCYLINDRICAL PACKAGE
Package formSnap-in
method of packingBulk
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)100 V
ripple current2450 mA
seriesUSC
surface mountNO
Delta tangent0.2
Terminal surfaceTin (Sn)
Terminal pitch10 mm
Terminal shapeSNAP-IN
LARGE CAN TYPE ALUMINUM ELECTROLYTIC CAPACITORS
USC
USC
SERIES
85℃ Standard, Snap-in Terminal Type
◆FEATURES
Load Life : 85℃ 3000 hours.
RoHS compliance.
◆SPECIFICATIONS
Items
Category Temperature Range
Rated Voltage Range
Capacitance Tolerance
I=3
CV
Leakage Current(MAX)
Characteristics
−40∼+85℃
10∼250V.DC
±20%
(20℃,
120Hz)
(After 5 minutes application of rated voltage)
−25∼+85℃
315∼450V.DC
I=(μA)
Leakage Current
10
16
C=(μF)
Rated Capacitance
50
63
V=(V)
Rated Voltage
(tanδ)
Dissipation Factor(MAX)
Rated Voltage
tanδ
120Hz)
80 100 160∼ 420∼
(20℃,
400 450
0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.25
25
35
After applying rated voltage with rated ripple current for 3000 hours at 85℃,
the capacitors shall meet the following requirements.
Capacitance Change
Endurance
Dissipation Factor
Leakage Current
Rated Voltage
Z
(−25℃) (20℃)
/Z
Z
(−40℃) (20℃)
/Z
Not more than 200% of the specified value.
Not more than the specified value.
315∼400 420∼450
(120Hz)
8
12
Within ±20% of the initial value.
Low Temperature Stability
Impedance Ration(MAX)
10∼250
3
12
◆MULTIPLIER FOR RIPPLE CURRENT
 Frequency Coefficient
Frequency
◆OPTION
Code
(Hz)
60
(50) 120
0.90
0.80
0.80
1.00
1.00
1.00
500
1.05
1.20
1.20
1k
1.10
1.30
1.25
10k≦
1.15
1.50
1.40
PET Sleeve without plate
EFC
10∼100WV
Coefficient
160∼250WV
315∼450WV
◆PART NUMBER
□□□
Rated Voltage
USC
Series
□□□□□
Rated Capacitance
M
Capacitance Tolerance
□□□
Option
SN
Terminal Code
D×L
Case Size
◆DIMENSIONS
SN
[4(3.5)mm½
terminal type
(mm)
SLEEVE
(PET)
VENT
2-φ2
NEGATIVE
10
10
±0.1
L±2
4±0.5
φD±1
φD±1
MOUNTING HOLES
※For φ35, 3.5±0.5
How to detect your own network status in evc under WinCE
Now, I want to make a square (red, green, yellow, etc.) on the program interface, and switch colors to indicate the network status. If it can't indicate good or bad, it can also indicate connected or ...
lyzc11 Embedded System
Design of wireless sensor nodes based on the characteristics of wireless sensor networks
Based on the characteristics of wireless sensor networks, this paper designs a wireless sensor node for temperature and humidity measurement with CC2430 chip as the core. In order to reduce the power ...
fish001 RF/Wirelessly
Discussion on the Development Trend of Power Management
If an active clamp PWM controller (such as UCC2894) is then added, the overall efficiency of the LCDTV power system can be optimized because a series of well-defined functions realize zero current swi...
peregrine Power technology
Intelligent power monitoring and protection system creative progress post + load automatic adjustment operation demonstration video (with load, extended function)
[i=s]This post was last edited by ltbytyn on 2014-1-4 22:38[/i] There are 4 loads in the demonstration, and the parameters of the 4 loads are set as follows. Branch 1: Low priority in automatic mode, ...
ltbytyn Renesas Electronics MCUs
This circuit cannot maintain constant current. Please analyze it.
The following is a constant current circuit diagram of a charging circuit. During debugging, it was found that the 5th pin of the dual op amp IC could not be stabilized. After disconnecting R35, it be...
灞波儿奔 Power technology
The Definitive Guide to Op Amps
[i=s] This post was last edited by paulhyde on 2014-9-15 09:10 [/i] The Definitive Guide to Op Amp, a super awesome book, sorry, I need a gold coin, because I need some gold coins to download the info...
电子笔小巴 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2782  2609  2252  1019  2755  57  53  46  21  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号