The JDSU near infrared fused coupler splits or combines light at any selected
wavelength from 700 to 1150 nm. Designed for applications in fiber laser, sensor
and avionics applications, the coupler utilizes low loss fused fiber technology. No
light leaves the fiber and therefore no alignment is required; and there are no
unwanted reflections. Furthermore the output fiber pigtails may be directly
integrated into beam delivery systems.
NORTH AMERICA
:
800 498-JDSU (5378)
WORLDWIDE
:
+800 5378-JDSU
WEBSITE
:
www.jdsu.com
FUSED COUPLER, NEAR INFRARED
2
Configuration
1x2
P1 (Red) COMMON (Input)
P2 (Blue) SIGNAL (Input)
P3 (Red) TAP (Output)
2x2
P1 (Red) COMMON (Input)
P2 (Blue) SIGNAL (Input)
P4 (Blue)
P3 (Red) TAP (Output)
Insertion Loss
Coupling Ratio
Grade
Available Housing Option
Signal Path Insertion Loss
1, 2
(Maximum)
0.9 dB
1.1 dB
1.5 dB
1.7 dB
2.2 dB
2.4 dB
3.0 dB
3.2 dB
3.8 dB
4.0 dB
Tap Path Insertion Loss
1, 2
(Maximum)
12.2 dB
12.4 dB
8.4 dB
8.6 dB
6.4 dB
6.5 dB
4.9 dB
5.1 dB
3.8 dB
4.0 dB
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
A
B
A
B
A
B
A
B
A
B
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
1. Insertion loss at operating wavelength range (not including PDL, TDL or connector losses).
2. In 2x2 couplers with a coupling ratio of 20% or lower, insertion loss is not specified for launch through second input port (P4).
FUSED COUPLER, NEAR INFRARED
3
Housing Option
Housing Code
3
4
5
6
Description
Regular
Ø 0.9 mm slim
Ø 0.9 mm semi-ruggedized
Ø 3.0 mm fully ruggedized
1x2, 2x2 Dimensions (mm)
3.0 (Ø) x 50 (L)
3.0 (Ø) x 60 (L)
5.0 (Ø) x 75 (L)
80 (L) x 10 (W) x 8 (H)
Pigtail
Primary-coated fiber
Ø 0.9 mm loose-tube
Ø 0.9 mm loose-tube
Ø 3.0 mm fan-out sleeving
Specifications
Parameter
Operating wavelength range
1
Excess loss
Return loss/Directivity
Pigtail tensile load
Optical power handling
Operating temperature range
2
Storage temperature range
Fiber type
Grade A
Grade B
Typical
Minimum
Maximum
Maximum
Any wavelength within the 700 to 1150 nm range
0.30 dB
0.50 dB
50 dB
5N
4W
-40 to 75 °C
-40 to 85 °C
Speciality fiber
1. Any specific wavelength point from within the range 633 to 850 nm may be selected. For wavelengths outside of this range, contact JDSU with specific requirements.
2. For connectorised component, operating temperature range is -5 to 75 °C.
FUSED COUPLER, NEAR INFRARED
4
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
customer.service@jdsu.com.
Sample: FFS-060K31A10 (Fused Fiber Speciality Coupler, 1060 nm, 50/50 coupling ratio, regular housing, 1x2, A grade, 1 m
pigtails, no connectors)
FFS-
Code
7
8
9
0
1
Wavelength
(First Digit)
7xx nm
8xx nm
9xx nm
10xx nm
11xx nm
Code
A
C
E
H
K
Coupling Ratio
1
10%
20%
30%
40%
50%
Code
1
2
Configuration
1x2
2x2
Code
0
1
3
5
9
A
B
Connectors
2, 4
None
FC/PC
FC/APC
SC/APC
FC/UPC
SC/UPC
LC
5
Code
A
B
Grade
Grade A
Grade B
Code
Wavelength
(Second and
Third Digit)
Examples:
33
x33 nm
32
x32 nm
57
x57 nm
Code
3
4
5
6
Housing
2
Regular
Ø 0.9 mm slim
Ø 0.9 mm
semi-ruggedised
Ø 3.0mm fully
ruggedised
Code
0
1
Pigtail Length
3
(Minimum)
0.5 meter
1 meter
1. Other coupling ratio are available. Please contact JDSU for ordering codes of coupling ratios not listed.
2. Connectors may be fitted to housing types 4, 5 and 6. For connectorisation of housing type 3, please contact JDSU sales office.
3. Minimum pigtail length. Other pigtail lengths are available on request. When the pigtail has been modified to include a
connector, pigtail length measurment includes the connector end face.
4. Excess Loss in specification table does not include connector losses.
5. LC connector is not available for housing code 6, fully ruggedised housing.
LC is a registered trademark of Lucent Technologies.
Circuit Function and AdvantagesThis circuit uses the AD5734BREZ, a quad, 14-bit, serial input, unipolar/bipolar voltage output DAC, and the REF192ESZ, a 2.5 V precision voltage reference, to provide u...
[align=left][color=rgb(85, 85, 85)][font=微软雅黑][size=12px]When the switching power supply is in working state, the electric energy is pumped from the input end to the output end in each switching proce...
The 12k should be the sampling rate. In the adc initialization function, I adjusted the frequency division coefficient between 6 and 8, and the period, which was 239.5 and 71, and the parameters 11 an...
Problem description: I copied a VC generated application (assuming the file name is PP.exe) to the Nand Flash directory of the Win CE 5.0 system through a USB flash drive. There is a certain probabili...
The bone vibration sensor from ST I received came with an FPC adapter board, which saved me the trouble of making PCB package and facilitated wiring test.However, because the voltage support is only 1...
The circuit shown in the figure is a three-digit tachometer used to measure low frequency signals with a repetitive time interval of 0.235 to 15 seconds. The tachometer has a speed range of 4 to 255 r...[Details]
The role of digital-to-analog converters
Real-world analog signals, such as temperature, pressure, sound, or images, are constantly being converted into digital form that is easier to store, p...[Details]
Blood pressure is one of the important physiological parameters of the human body. Accurate measurement of it is conducive to early detection and identification of hypertension types, and to the pro...[Details]
Keeping the heart environment compact and warm is beneficial in most cases, but it’s another story for electronic heart scanners. When GE Healthcare was designing a scanner that was said to be the fas...[Details]
As a single-host multi-slave bus system, the number of slave devices that can be connected to a 1-Wire bus is almost unlimited. In order to avoid logical conflicts, the 1-Wire bus interfaces of all...[Details]
As the price of readers and tags decreases and the global market expands, the application of radio frequency identification (RFID) is increasing day by day. Tags can be powered by readers (passive ...[Details]
This summary will introduce the transmitter characteristic test of TD terminal products - uplink power control. According to the 3GPP TS34.122 standard, UE uplink power control is divided into uplink ...[Details]
Signal sources have developed to a very wide range today. We can classify them according to the frequency range: ultra-low frequency (0.1m~1kHz), audio (20Hz~20kHz), video (20kHz~10MHz), radio fre...[Details]
0 Introduction
SAA7111 is a programmable video processor produced by Philips. The chip integrates A/D and decoding functions. It has phase lock, automatic clamp, automatic gain control, cl...[Details]
introduction
The fall detector is suitable for elderly people and children with poor self-care and self-protection abilities. It senses changes in the body posture of the individual wearing th...[Details]
Complex circuits and 3D EM simulation tools have reached a point where complex system-level behavior can be simulated before fabrication. Performing EM simulations simultaneously with circuit simul...[Details]
Designers of handheld products such as cell phones, digital cameras, MP3 players and personal digital assistants (PDAs) are continually challenged to deliver more functionality in a smaller form...[Details]
Murphy's Law tells us that "what can go wrong, will go wrong". In the testing or production process of video equipment, problems often occur when we least want them to happen and when it is leas...[Details]
introduction
With the improvement of social automation, human-computer interaction capabilities urgently need a major change, and develop in a direction that is more convenient to use and more...[Details]
With the improvement of social automation, human-computer interaction capabilities urgently need a major change, and develop in a direction that is more convenient to use and more intuitive. Laser ...[Details]