EEWORLDEEWORLDEEWORLD

Part Number

Search

KA-G4K

Description
Power/Signal Relay, 4PDT, Momentary, 3220mW (Coil), 10A (Contact), 28VDC (Contact), AC Input, AC/DC Output, Socket Mount,
CategoryMechanical and electronic products    relay   
File Size727KB,12 Pages
ManufacturerEsterline Power Systems
Download Datasheet Parametric View All

KA-G4K Overview

Power/Signal Relay, 4PDT, Momentary, 3220mW (Coil), 10A (Contact), 28VDC (Contact), AC Input, AC/DC Output, Socket Mount,

KA-G4K Parametric

Parameter NameAttribute value
MakerEsterline Power Systems
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 105 V, COIL RELEASE VOLTAGE(AC): 30 V; PANEL MOUNTABLE
body width25.78 mm
body height25.4 mm
Body length or diameter25.78 mm
Coil current (AC) maximum value0.028 A
Coil power3220 mW
Maximum coil voltage (AC)115 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load10A@115VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
JESD-609 codee4
Installation featuresSOCKET MOUNT
operating hours21 ms
Maximum operating temperature125 °C
Minimum operating temperature-70 °C
physical size25.78mm x 25.78mm x 25.4mm
GuidelineMIL-PRF-83536
Relay actionMOMENTARY
Relay function4PDT
Relay typePOWER/SIGNAL RELAY
release time50.1 ms
sealCORROSION PROOF; HERMETICALLY SEALED
surface mountNO
Terminal surfaceGOLD
Termination typeSNAP-ON
SERIES KA
ENGINEERING DATA SHEET
RELAY - NONLATCH - AC COIL
4 PDT, 10 AMP
115 Vac and 28 Vac, 400 Hz and 50/400 Hz coil voltages
All welded construction
Contact arrangement
Qualified to
4 PDT
MIL-PRF-83536
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions
28 Vdc; 115 Vac, 400 Hz, 1Ø and
115/200 Vac, 400 Hz 3Ø
0.155lb max
1.10in x 1.10in x 1.00in
Special models available upon request.
Hermetically sealed, corrosion resistant metal can.
APPLICATION NOTES:
102
007
023
APPLICABLE SOCKET:
SO-1048-8776/8779
CONTACT ELECTRICAL CHARACTERISTICS
Contact rating
per pole and load
type [1]
Resistive
Inductive [3]
Motor
Lamp
Overload
Rupture
Load current in Amps
@28 Vdc
10
8
4
2
40
50
@115 Vac
400 Hz
10
8
4
2
60
80
@115/200 Vac
400 Hz, 3Ø
10
8
4
2
60
80
@115/200 Vac
60 Hz, 3Ø [2]
2.5
2.5
2
1
N/A
N/A
@230/400 Vac
400 Hz, 3Ø [8]
5
5
2
2
N/A
N/A
Featuring
LEACH
©
power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 07/10
- 101 -
Page 1 of 4
Looking for the source code of msp430f4784
Great God, please provide the source code of msp430f4784. Great God, please provide the source code of msp430f4784....
manmanroad Microcontroller MCU
Analysis of DSP's CMD file (Part 2) [Transfer]
Writing CMD files 1 COFF format 1 Common Object File Format is a popular binary executable file format. Binary executable files include library files (lib), object files (obj) and final executable fil...
kooking DSP and ARM Processors
STM32 price has increased
The price has increased a lot. I think in the future, try not to use popular microcontrollers when making products. Damn, the price has increased....
6688hyc Automotive Electronics
How does MSP30 implement the function of power-off protection data? ? ?
I want to build a system to measure some data, store the measured data in variables, and save it to FLASH at 8 am every day, but I am afraid that there will be no power in the middle. Can MSP430F1XX o...
scorpio Microcontroller MCU
Look at my results
I have been engaged in the development and application of single-chip microcomputers for a long time and have accumulated a certain amount of experience. I have integrated my life-long research experi...
69056001 Embedded System
The difference between a two-pipe wired controller and a four-pipe thermostat
[size=4]To talk about the two-pipe and four-pipe thermostats, we must first talk about the cooling and heating principles. The cooling and heating principles of thermostats are similar to water coolin...
灞波儿奔 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2372  182  2888  1658  1509  48  4  59  34  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号