EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-J74IX

Description
DC-DC Converters 25 to 100 Watts
File Size26KB,2 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet View All

VI-J74IX Overview

DC-DC Converters 25 to 100 Watts

12
1-800-735-6200
VI-J00
MiniMod
DC-DC Converters
25 to 100 Watts
Features
s
s
s
s
s
s
s
s
s
s
Up to 50W/Cubic Inch
UL, CSA, TÜV, VDE, BABT
CE Marked
Up to 90% Efficiency
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
Remote Sense and Current Limit
Logic Disable
Wide Range Output Adjust
ZCS Power Architecture
Low Noise FM Control
Nominal
0 =
1 =
W=
2 =
3 =
N =
4 =
T =
5 =
6 =
7 =
Rev 3 1 of 2
Converter Selection Chart
VI-J
Input Voltage
Range
Brownout
/
Transient
*
22V
36V
n/a
60V
72V
n/a
110V
n/a
215V
425V
n/a
12V
10 - 20V(5) n/a
24V
21 - 32V(2) 18V
24V
18 - 36V(2) n/a
36V
21 - 56V(6) 18V
48V
42 - 60V(3) 36V
48V
36 - 76V(2) n/a
72V
55 - 100V(2) 45V
110V
66 - 160V(2) n/a
150V
100 - 200V(2) 85V
300V
200 - 400V(3) 170V
150/300V 100 - 375V(6) 90V
Output Voltage
Z =
2V
Y = 3.3V
0 =
5V
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
2
N
3
L
J
K
4
H
F
D
B
= 15V
= 18.5V
= 24V
= 28V
= 36V
= 40V
= 48V
= 52V
= 72V
= 85V
= 95V
Product Highlights
The VI-J00 MiniMod family establishes
a new standard in component-level
DC-DC converters. This “junior” size
complement to the higher power VI-200
family offers up to 100W of isolated and
regulated power in a board mounted
package. At one-half the size and twice
the power density of previous 100W
modules, and with a maximum operating
temperature rating of 100˚C, the MiniMod
opens new horizons for board-mounted
(distributed) power architectures.
Utilizing Vicor’s “zero-current-
switching” forward converter technology,
proven by an installed base of over
8 million units, the MiniMod family
combines state of the art power density
with the efficiency, low noise and
reliability required by next generation
power systems.
Product Grade/
Operating Temp.
E =
C =
I =
M=
-10°C
-25°C
-40°C
-55°C
to
to
to
to
+100°C
+100°C
+100°C
+100°C
Product Grade/
Storage Temp.
E
C
I
M
=
=
=
=
-20°C
-40°C
-55°C
-65°C
to +105°C
to +105°C
to +105°C
to +105°C
Z
Y
X
W
Output Power/Current
V
OUT
5V
=
25W
=
50W
=
75W
= 100W
Z
Y
X
W
V
OUT
< 5V
=
5A
=
10A
=
15A
=
20A
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs
(1)
50W
50W
10A
(2)
75W
100W
20A
(3)
100W
100W
20A
*Brownout 75% of rated load; transient voltage for 1 second.
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs
(4)
75W
75W
15A
(5)
50W
75W
15A
(6)
50W
75W
10A
Mechanical Drawing
.49
(12,4)
.30±.015
(7,6)±(0,38)
.65
(16,5)
2.28
(57,9)
1.30
(33,0)
.080 Dia (2) places
Solder plate
over copper alloy
Pin #
1
4
3
2.10
(53,4)
2
9
8
2
3
1.40
1.00 (35,6)
(25,4)
4
5
6
.35± .015
(8,9)±(0,38)
7
8
9
.15
(3,8)
FULL R
.15
(3,8)
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
Product ID
this surface
.22
(5,6) Min.
.30
(7,6) Min.
Function
+In
Gate In
Gate Out
-In
+Out
+Sense
Trim
–Sense
–Out
VI-J00
7
6
5
.70
.40 (17,8)
(10,2)
Packaging Options
SlimMods™, high power density,
flangeless packages and FinMods™,
featuring integral finned heatsinks.
SlimMod:
Option suffix:
- S
Example: VI - JXX - XX
- S
FinMod:
Option suffix:
- F1
and
- F2
Examples:
VI - JXX - XX -F1, 0.75" height
VI - JXX - XX -F2, 1.00" height
.12
(3,0)
1
2.40
(61,0)
1.75
(44,4) Max.
1.90
(48,3)
.50
(12,7)
+.030 (0,76)
-.000 (0)
.01
Aluminum Base
For the latest Vicor Product Information: www.vicorpower.com
Technical guidance: Correct usage of Keep-Out and Mechanical 1 for the new AD17 and AD18!
After the AD software was upgraded to AD17 and AD18, some customers still used the Keep-Out layer to draw the shape or mechanical holes (strip slots) with the software drawing board. When it is opened...
szjlczhang PCB Design
Can't comment Chinese statements in ccs3.1?
Hello everyoneI am using ccs3.1, why can't I write Chinese comments directly in it? Comments can be written in English or numbers.Also, only 2407.h (I use 2407) can be automatically added to the inclu...
cailong DSP and ARM Processors
Please come and see what's wrong with my graduation project
I am currently working on my graduation project, but I have encountered some problems. Please come and help me. Below is my program ORG 0000H LJMP MAIN ORG 0003H ;External interrupt 0 entry (night mod...
mrfantexi 51mcu
Op amp issues
According to the analog electronics book edited by Kang Huaguang, when designing an op amp circuit, the resistance of the op amp peripheral circuit is generally in the kilo-ohm level. However, in vari...
碧火深蓝 Analog electronics
Simpliti communication protocol
I want to ask, I am doing simpliti communication, the node has always sent data to the gateway, but I have never tried to send data from the gateway to the node. I don't know which god knows the under...
小@小哒哒何 RF/Wirelessly
Qorvo Design Summit Webinar Series Returns
Qorvo (Nasdaq: QRVO), a leading provider of innovative RF solutions for mobile, infrastructure and aerospacedefense applications, today announced that its popular “Design Summit” webinar series has re...
兰博 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1205  590  565  2873  1206  25  12  58  29  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号