LTGMO51D-TB-W-R/6V

Description
Rocker Switch, DPST, Momentary, Quick Connect Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size112KB,1 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

LTGMO51D-TB-W-R/6V Overview

Rocker Switch, DPST, Momentary, Quick Connect Terminal, Rocker Actuator, Panel Mount

LTGMO51D-TB-W-R/6V Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width25.24 mm
body height20.62 mm
Body length or diameter28.45 mm
Contact (AC) maximum rated R load15A@125VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)125 V
Electrical life25000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial numberLTG
Installation featuresPANEL MOUNT
Maximum operating temperature66 °C
Minimum operating temperature
surface mountNO
Switch actionMOMENTARY
switch functionDPST
Switch typeROCKER SWITCH
Termination typeQUICK CONNECT
Carling
Technologies
TG/LTG-Series Rocker Switches
TG/LTG-Series Rocker Switches
The TG-Series Mini Tippette rocker switches are single or
double pole and feature an all nylon double-insulated con-
struction. These switches are designed with snap-in mount-
ing for fast, low cost assembly. The illuminated version
(LTG) is available with either a paddle or rocker actuator.
These AC rated switches are also suitable for low-voltage
DC applications in a wide range of markets including
Appliance, HVAC, Food service, and Transportation.
Dielectric Strength
UL/CSA:
1000V - live to dead metal parts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 150°F (0°C to +65.6°C)
.069[1.75] DIA
.156[3.96] DIA
.055[1.40] DIA
6.000[152.40]
.375[9.52]
.250[6.35]
.500[12.70]
1.155[29.33]
.865[21.97]
.050[1.27]
1.240[31.50]
.250[6.35]
.250 TAB (Q.C.)
.250[6.35]
SOLDER LUG
.187[4.74]
.187 TAB (Q.C.)
INTEGRATED WIRE LEAD
(no exposed conductors)
TERMINAL TYPE
.210[5.33]
.812[20.62]
.520[13.20]
1.125[28.57]
.375[9.52]
1.120[28.45]
PADDLE
1.000[25.40]
.994[25.24]
MOUNTING HOLE
Panel Thickness:
.030[.762] min. to
.250[6.35] max.
LTG G O 50 1
-
T B
-
B
-
R
/
125N
1
Base Part Number
2
Circuit
3
Center
Position
4
Rating
5
Termination
6
Actuator
Style
7
Actuator
Color
8
Base Color
9
Lens Color
10
Lamp
Voltage
1 BASE PART NUMBER: SERIES
1
TG
Double Pole, Non-Lighted
LTG
Double Pole with Indicator Lights
2 CIRCUIT
See Circuit Designation Chart Page 17.
3 CENTER POSITION
C
Center OFF, Three position
O
No Center OFF, Two position
4 RATING
40
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
41
5A 250VAC, 10A 125VAC
50
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
51
10A 250VAC, 15A 125VAC
5 TERMINATION/FUNCTION
solder lug
ON-NONE-OFF
0
(ON)-NONE-OFF
A
ON-NONE-(OFF)
L
ON-NONE-ON
0
ON-NONE-(ON)
A
ON-OFF-ON
0
6 ACTUATOR STYLE
P
paddle
7 ACTUATOR COLOR
2
B
black
8 BASE COLOR
2
B
black
9 LENS COLOR
3
A
amber
10 LAMP VOLTAGE
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
wire leads
5
F
T
5
F
5
T
rocker
W
white
W
white
C
clear
R
red
neon
125N
125 volt neon
250N
250 volt neon
.250 tab QC
1
B
M
1
B
1
.187 tab QC
3
D
R
3
D
3
NOTES
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same direction as the punch. (Burr on bottom.) Test cut hole in actual material.
1
TG available with circuits A, B, C, D, E, F ; LTG available with circuits G, H, I, J, M, N, P, Q, R, T, U, V, Y, Z. See page 17.
2
Custom colors are available. Consult factory.
3
Specify lens color for LTG-Series only.
()
Indicates momentary function.
14
www.carlingtech.com
New Year's greetings guessing game
[i=s]This post was last edited by miaozhuang156 on 2016-1-16 10:55[/i] Guys, come and guess:loveliness:[audio]attach://227978.mp3[/audio]...
miaozhuang156 Talking
WinCE set IP
As the title suggests, it would be best to give the code....
star_jia Embedded System
Play with Zhilin STM32 development board with the latest library (Part 8) --- Display Chinese characters on the true color screen
Hello everyone! I haven't posted for a long time because I was on a business trip. I will post it in a few days. Take your time. If you have Zhilin board, you can put all the files into a directory. T...
ddllxxrr stm32/stm8
I modified the platform.reg file, but it didn't work after I made the Run-Time Image?
PB5.0 + 2410 I changed the device name in the platform.reg file as follows: ; Assigning a Device Name [HKEY_LOCAL_MACHINE\Ident] "OrigName"="WinCE" "Name"="MyDevice" Saved, then made a Run-Time Image,...
强化工业 Embedded System
Why can't I download the program?
Every time I download a program to mps430f1611, it always displays:Mon Nov 09 17 Is the software incompatible with the system?...
catdud Microcontroller MCU
LCD1602 display error.........Help
After downloading the program, it can run normally (both lines can be displayed), but after turning off the power and then turning it on again, only one line is displayed.... At first, it was because ...
wang7588038 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 23  18  2649  2020  2307  1  54  41  47  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号