Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60320-1; IEC/EN 60950; UL 94V-0; CSA; VDE; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings10A, 250/125VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Power entry modules with line filter
www.schurter.com/pg06
Inlet filter, front side mounting, circuit breaker TA45 2-pole
545
Standard- or Medical-Filter
Screw-On Version
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter 6145
- We recommend for new applications the new type DF12
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Weblinks
Approvals
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
- VDE License Number: 117118
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21acc. to, IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit breaker
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC products

How to generate Excel table from CListctrl data in Evc
When porting the Excel program generated by CListctrl in VC to Wince, #include #include#include These three header files have errors in Evc fatal error C1083: Cannot open include file: 'io.h': No such...
edwinrong Embedded System
API library function call problem
I am now using IAR to develop a processor with an ARM core. Can I directly call the API library function (*rgb(0, 0, 0) provided by the manufacturer)? If so, what are the methods and steps? Thank you!...
arrow_02 ARM Technology
Analog electronics course selection test + isolation course learning
Step 1: Open the link https://bbs.eeworld.com.cn/huodong/TI_hpl/index.phpStep 2: Select the course you are interested in. I chose TI's isolation devices.Step 3: Open the course link to watch the video...
xiaoweiqq TI Technology Forum
Switching Power Supply Simulation PSPICE and SPICE 3 Application
Switching Power Supply Simulation PSPICE and SPICE 3 Applications This book fully explains the basics of modeling and SPICE simulation methods, covering all aspects of circuit simulation technology, i...
qwqwqw2088 Analogue and Mixed Signal
Homemade Laser Engraving Machine Information
[size=14px]Link: [url]http://pan.baidu.com/s/1eROEzkQ[/url] Password: ccex[/size] [size=14px]Let's get straight to the data. If you want to support me, just give my post a thumbs up. [/size] [size=14p...
guaibaobao2 DIY/Open Source Hardware
Savor life and feel happiness
When I was a child, happiness was a simple thing; when I grow up, simplicity is a very happy thing. [[i] This post was last edited by Crazy_HUA on 2012-11-13 12:25[/i]]...
Crazy_HUA Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2073  1683  319  2563  2117  42  34  7  52  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号