MIL–PRF (CWR Style) Established Reliability – T409 Series CWR09 Style MIL–PRF–55365/4
Table 1 – Ratings & Part Number Reference
Rated
Voltage
V
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25
25
V
Rated
Cap
µF
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
0.33
0.68
1
1.5
2.2
4.7
6.8
µF
Case Code/
Case Size
KEMET/EIA
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T409A225(1)004(2)(3)(4)
T409B475(1)004(2)(3)(4)
T409C685(1)004(2)(3)(4)
T409D106(1)004(2)(3)(4)
T409E156(1)004(2)(3)(4)
T409F336(1)004(2)(3)(4)
T409G686(1)004(2)(3)(4)
T409H107(1)004(2)(3)(4)
T409A155(1)006(2)(3)(4)
T409B335(1)006(2)(3)(4)
T409C475(1)006(2)(3)(4)
T409D685(1)006(2)(3)(4)
T409E106(1)006(2)(3)(4)
T409F226(1)006(2)(3)(4)
T409G476(1)006(2)(3)(4)
T409H686(1)006(2)(3)(4)
T409A105(1)010(2)(3)(4)
T409B225(1)010(2)(3)(4)
T409C335(1)010(2)(3)(4)
T409D475(1)010(2)(3)(4)
T409E685(1)010(2)(3)(4)
T409F156(1)010(2)(3)(4)
T409G336(1)010(2)(3)(4)
T409H476(1)010(2)(3)(4)
T409A684(1)015(2)(3)(4)
T409B155(1)015(2)(3)(4)
T409C225(1)015(2)(3)(4)
T409D335(1)015(2)(3)(4)
T409E475(1)015(2)(3)(4)
T409F106(1)015(2)(3)(4)
T409G226(1)015(2)(3)(4)
T409H336(1)015(2)(3)(4)
T409A474(1)020(2)(3)(4)
T409B684(1)020(2)(3)(4)
T409B105(1)020(2)(3)(4)
T409C155(1)020(2)(3)(4)
T409D225(1)020(2)(3)(4)
T409E335(1)020(2)(3)(4)
T409F685(1)020(2)(3)(4)
T409G156(1)020(2)(3)(4)
T409H226(1)020(2)(3)(4)
T409A334(1)025(2)(3)(4)
T409B684(1)025(2)(3)(4)
T409C105(1)025(2)(3)(4)
T409D155(1)025(2)(3)(4)
T409E225(1)025(2)(3)(4)
T409F475(1)025(2)(3)(4)
T409G685(1)025(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/4
Part Number
(See below for
part options)
CWR09C(3)225(1)(2)(5)
CWR09C(3)475(1)(2)(5)
CWR09C(3)685(1)(2)(5)
CWR09C(3)106(1)(2)(5)
CWR09C(3)156(1)(2)(5)
CWR09C(3)336(1)(2)(5)
CWR09C(3)686(1)(2)(5)
CWR09C(3)107(1)(2)(5)
CWR09D(3)155(1)(2)(5)
CWR09D(3)335(1)(2)(5)
CWR09D(3)475(1)(2)(5)
CWR09D(3)685(1)(2)(5)
CWR09D(3)106(1)(2)(5)
CWR09D(3)226(1)(2)(5)
CWR09D(3)476(1)(2)(5)
CWR09D(3)686(1)(2)(5)
CWR09F(3)105(1)(2)(5)
CWR09F(3)225(1)(2)(5)
CWR09F(3)335(1)(2)(5)
CWR09F(3)475(1)(2)(5)
CWR09F(3)685(1)(2)(5)
CWR09F(3)156(1)(2)(5)
CWR09F(3)336(1)(2)(5)
CWR09F(3)476(1)(2)(5)
CWR09H(3)684(1)(2)(5)
CWR09H(3)155(1)(2)(5)
CWR09H(3)225(1)(2)(5)
CWR09H(3)335(1)(2)(5)
CWR09H(3)475(1)(2)(5)
CWR09H(3)106(1)(2)(5)
CWR09H(3)226(1)(2)(5)
CWR09H(3)336(1)(2)(5)
CWR09J(3)474(1)(2)(5)
CWR09J(3)684(1)(2)(5)
CWR09J(3)105(1)(2)(5)
CWR09J(3)155(1)(2)(5)
CWR09J(3)225(1)(2)(5)
CWR09J(3)335(1)(2)(5)
CWR09J(3)685(1)(2)(5)
CWR09J(3)156(1)(2)(5)
CWR09J(3)226(1)(2)(5)
CWR09K(3)334(1)(2)(5)
CWR09K(3)684(1)(2)(5)
CWR09K(3)105(1)(2)(5)
CWR09K(3)155(1)(2)(5)
CWR09K(3)225(1)(2)(5)
CWR09K(3)475(1)(2)(5)
CWR09K(3)685(1)(2)(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Maximum/5
Minutes
1
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
5.0
1.0
1.0
1.0
1.0
1.0
2.0
4.0
5.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
µA @ +20ºC
Maximum/5
Minutes
DF
% @ +20ºC
120 Hz
Maximum
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
% @ +20ºC
120 Hz
Maximum
ESR
Ω @ +20ºC
100 kHz
Maximum
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
6.5
3.5
2.5
1.2
Ω @ +20ºC
100 kHz
Maximum
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
MIL-PRF-55365/4
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates termination finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, or C = -55°C +85°C before Weibull. Designates surge current
option. Refer to Ordering Information for additional detail.
The internal design of CH2601 has an IIC bus. The I2C bus on the board is connected to ES7210. The ES7210 chip is a four-channel ADC acquisition chip. A silicon microphone is connected to the board.Th...
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:00[/i] Recently, before Apple launched the 3G iPhone this summer, one of the speculations was that Apple would launch a 3G iPhone with ...
LM3S9B96 lock problem. I made a LM3S9B96 PCB, but it always locks during debugging. I can also unlock it through JLINK, but I can't debug it. It's so troublesome!...
The author of this article, David Byttow, is a programmer who has worked at companies such as Google and Square. Before the main text, let's answer a few simple questions: First, how many companies ha...
The 5438 clock, when an error occurs, the document says: [align=left][size=14.0pt]If a fault is detected for the oscillator sourcing MCLK , MCLK is automatically switched to the DCO for its clock sour...
STM32 has two watchdogs: independent watchdog and window watchdog. This article mainly introduces the use of independent watchdog. Independent watchdog (IDWG): driven by an independent 40KHZ low-sp...[Details]
LiDAR: Autonomous driving from the perspective of optoelectronic technology LiDAR and competing sensor technologies (camera, radar, and ultrasonic) intensify the need for sensor fusion and the need...[Details]
ADI has established long-term good relationships with car manufacturers and Tier 1 component suppliers. Based on its previous long-term successful cooperation with new energy vehicles and suppliers a...[Details]
STM32 ADC multi-channel conversion Description: Use ADC to continuously collect 11 analog signals and transfer them to memory through DMA. ADC is configured to scan and continuously convert mode,...[Details]
Summary of STM32 peripheral DMA usage: 1. Select DAM mode according to your needs: (1) Circular mode—DMA_Mode = DMA_Mode_Circular (2) Normal mode—DMA_Mode = DMA_Mode_Normal 2. For Chanel3 of DMA1, t...[Details]
Getting to the bottom of blockchain
Since last year, blockchain has become the hottest word in both the financial and non-financial circles. Some people use it as a gimmick to engage in va...[Details]
Design a program for the 51 single-chip microcomputer. It is known that the crystal oscillator frequency of the 89C51 single-chip microcomputer is 12MHz, and it is required to use T1 timing to output...[Details]
A group of young people who looked like they were in their twenties or thirties were squatting on the edge of the factory flower bed. Some were looking at their phones helplessly, while others were...[Details]
Recently, the "2018 Household Photovoltaic Development Seminar" was successfully held in Hangzhou, Zhejiang Province. Sungrow attended the conference as a special co-organizer and summarized the statu...[Details]
Recently, the media reported that a photovoltaic project in Fujian caught fire, the components were burned, and the photovoltaic inverter and distribution box were intact. The specific cause of the...[Details]
The power battery production line company has strong technical strength and a R&D team with senior engineers as the core, and is committed to becoming a first-class expert in new energy automation ...[Details]
"Thanks to a number of new technological breakthroughs, Ginlong Technology has applied hardware dead zone technology on the fourth-generation inverter to achieve double safety protection. AFCI arc ...[Details]
China Energy Storage Network News:
On October 30th, local time in the United States, Liu Zhenya, Chairman of the Global Energy Interconnection Development Cooperation Organization and Chairma...[Details]
Inverter, also known as inverter power supply, is a current conversion device that converts DC power into AC power. Photovoltaic inverter is an inverter used in solar photovoltaic power generation ...[Details]
From December 12 to 13, the 2016 Sixth "One Belt, One Road" Distributed Energy Innovation and Development Summit Forum on Strengthening the Application of the Yangtze River Economic Belt was held i...[Details]